Fire fighting pumping unit GRUNDFOS

NBF is an end-suction pump made for fire sprinkler pump applications. NBF is a close-coupled type and NKF is a long-coupled type. The NKF fire system is an NBF or NKF end-suction...

Explosion proof actuator for fire and smoke protection SIEMENS Building Technologies

Actuators for fire and smoke protection dampers Actuators for Fire Protection Dampers OpenAir™ actuators for fire protection dampers are at the interface between highly integrated security systems and people. They work extremely relably especially in emergency situations....

Infrared camera for firefighting FLIR HF-Serie FLIR SYSTEMS

The HF-Series are rugged handheld thermal imaging cameras that can be used for firefighting applications. Thermal imaging cameras do not need any light whatsoever to create a crisp image. And maybe even more...

 

Spiral fire protection nozzle 1 720 l/min | N series BETE

N Fire Protection Design Features * Simplicity of design * One-piece/no internal parts * Clog-resistant * Three standard pipe sizes—½", 1" and 1½" * Male connection * Factory Mutual, U.S. Coast Guard and Lloyd's Register approved models Spray Characteristics * Two spray cones—an outer, wide angle cone...

4

Centrifugal engine-driven pump for fire fighting Cummins Engines

Since we produced our first fire pump driver in 1954, Cummins has known that every second counts in this critical application of our engines. Now, over fifty years later, we've launched a new line of fire pump drivers through Cummins Fire Power. Cummins Fire...

 

Single-stage centrifugal fire pump max. 600 m³/h, max. 160 m | Etanorm FXV KSB

Horizontal, long-coupled, single-stage volute casing...

Clean agent fire extinguishing system ECARO-25® Fike Europe

Water-based fire suppression systems (sprinklers) are designed to protect people and structures. But when it comes...

6

Fire hose reel F1500 series HANNAY REELS

Ideal for use with 1/2" breathing air hose, Hannay Reels F1500 Series model is designed for firefighting and rescue operations,...

4
 

Explosion proof actuator for fire and smoke protection ExMax, RedMax, ATEX, 5-60 Nm, 90° Schischek Explosionproof

Actuators (90° quarter turn actuators) for fire dampers, explosion proof Electrical, explosion proof quarter turn actuators series ExMax and RedMax, for fire dampers. - 5-60 Nm - ATEX 94/9/EC - installation in hazardous areas zone 1, 2, 21 and 22 - for all kind of gas, vapours, mixtures and dust - Actuators...

Automatic fire fighting unit max. 312 m3/h, EN 12845 | FFS-FFBE series EBARA

The EBARA FFS-FFB type pressure boosting units are applied in the automatic activation water supplies for the automatic fire fighting units in compliance with European Standard UNI EN 12845. Specifications As established by the UNI EN 12845 Standard, if the firefighting unit supply pumps intervene,...

2

Clean agent fire extinguishing system ECARO-25® Fike

Water-based fire suppression systems (sprinklers) are designed to protect people and structures. But when it comes to protecting high value machinery, computers and other electronic...

6
 

Dry sprinkler 1 -2 cfm, 13 psi GAST

Dry Sprinkler Systems View our new Dry Sprinkler Catalog UL...

2

Fire hose 3/4" - 1", 800 psi, -18 - 82 °C Goodyear Conveyor Belts

For use in high-pressure fire engine booster service. Also has many applications in other heavy-duty industrial and municipal operations. CONSTRUCTION: TUBE: Synthetic rubber...

Mobile centrifugal engine-driven pump for fire fighting max. 1 000 l/min, max. 10 bar | GT 10/10 Godiva Ltd.

De-mountable fire pump on a two wheeled road going trailer. Rated pump performance...

21
 

Split case fire pump max. 7 000 gpm | 1800F, 5800F, 5900F, HGT series Fairbanks Nijhuis

Fairbanks Nijhuis supplies split case fire pumps that meet NFPA, EN, VAS and APSAD standards in full, as well as being UL listed, FM and VdS approved. Fire pump sets are available with electric motor, diesel engine...

7

Firebreak system for electric cable OBO Bettermann

Function maintenance DIN 4102 part 12 Maintaining the power supply in the event of fire. Function maintenance of electrical cable systems which supply equipment of relevance to safety is an important topic when...

 

Automatic fire fighting unit max. 312.00 m3/h, UNI EN 12845 | FFS-FFBE series EBARA PUMPS EUROPE

The EBARA FFS-FFB type pressure boosting units are applied in the automatic activation water supplies for the automatic fire fighting units in compliance with European Standard UNI EN 12845. Specifications As established by the UNI EN 12845 Standard, if the firefighting unit supply pumps intervene,...

2

Split case fire pump max. 5000 gpm | Thrustream series SPP

Thrustream Split Case Fire Pumps SPP Pumps have been manufacturing fire pumps for over 130 years and with one of the widest range of approvals of any manufacturer in the world. Experience gained from extreme environments such as off-shore oil & gas installations has led to the creation of the SPP Pumps Thrustream and Hydrostream range of pumps approved for fire protection...

4

Aerosol generator 7.811 series Grimm Aerosol Technik

This model has two pumps inside, one for the flow through a nebulizer (generating aerosol raw concentration) and a second pump which provides...

2
 

Vertical turbine fire pump max. 7 000 m³/h, max. 3 000 m |CUP-VS1 ClydeUnion

The ClydeUnion Pumps CUP-VS1 is a vertical turbine radial flow or axial flow type, multi-stage, heavy-duty pumps designed to the latest edition of API 610 and API...

Fire hose fitting RF PEX™ Watts Water Technologies

RF PEX™ Inline Fittings for ResFire Lead Free* Models Available Description: RF...

3

Two stage double suction centrifugal pump max. 8 000 gpm, max. 2 200 psig | DDH series WEIR Oil & Gas

The DDH line pumps are horizontal, between bearings, two stages, double suction first stage impeller with a radially split casing. Pump components geometry optimised through hydraulic, structural, thermal and...

 

Flame arrester BAM, C2H2, H2, O2 WITT-Gasetechnik

WITT safety devices are used to protect single cylinders, outlet points or pipelines against gas back...

Fire hose DN 25, max. 180 PSI, max 60°C | L-283 AA series ALFAGOMMA

TUBE : BLACK SYNTHETIC ELASTOMER REINFORCEMENT : HIGH TENSILE TEXTILE CORDS COVER : BLACK...

Explosion proof actuator for fire and smoke protection 5 - 20 Nm, 80 - 265 VAC/DC GRUNER

To regulate fire and smoke dampers in HVAC systems: • Form-locking steel drive •...

 

Fire hose fitting 3/4" x 1/2" - 1" x 1/2" | 5003-S-BT NIBCO

Robust starter thread to prevent sprinkler cross-threading...

Fume exhaust roof fan 355 - 710 mm, 28 100 m3/h ROSENBERG

Smoke Extract Roof Fans F400 (400°C / 120 min.) vertikal outlet operation of tested...

 

Double suction centrifugal pump 2,5 - 500 m³/h | RNL series Bombas Ideal

Applications - Water supply systems - Booster units - Heating and cooling systems - Liquid transfer in industry - Air conditioning systems Design Feature -...

6

Infrared camera for firefighting 7 - 14 µm, -15 - 260 °C | FX 160 Infrared Cameras Inc. (ICI)

The ICI FX 160 The ICI FX-160 is a rugged, portable, thermal imager; built to withstand extreme environments with a rating of IP 67. It has a drop test rating of 5.9 feet. Its one handed operation makes it simple and easy to use. The large 3.5” LCD display produces an exceptional image. An optional kevlar coating allows operating...

 

Portable powder extinguisher Jonesco

Dry Powder Fire Extinguishers are suitable for mixed fire risk environments and are especially suitable for flammable liquids and fires involving flammable gasses such as methane, propane, hydrogen, natural gas etc. Multi-purpose powder extinguisher interferes with the combustion process...

21

Fire hose FW AFW Lufttechnik GmbH

An exhaust hose suspended from the ceiling is secured to the exhaust pipe using an exhaust grommet and clamping pliers. This exhaust grommet is fitted with an automatic clamping...