Over the past century, GE has designed and manufactured literally tens of thousands of medium and high voltage circuit breakers. Although many of the older designs are no longer manufactured, many units remain in service. GE can deliver solutions for these breakers without the cost and downtime associated with complete equipment replacement. If you have any of the following breakers in service, we can provide parts or engineered solutions to support your maintenance needs:
Features and Benefits
* Parts designed and manufactured to the original or improved specifications.
* Parts in stock for fast delivery when you need them.
* Engineering support to provide support for your specific requirements.
* Extend the service life of your equipment with Genuine GE Parts, designed by the original manufacturer assuring reliable fit and performance.
* Increase rating capacity with packaged engineered solutions.
* Save time with easy to install original parts
* On-site service installation or supervision optionally available.
|
|
|
|
|
|
Gerapid high speed DC circuit breakers are single-pole circuit breakers designed for use in high energy, high reliability DC power distribution systems. They are suitable for protection of mains and semiconductors (converters/rectifiers) in railway and industrial applications. Feeder circuit breakers and rectifier circuit breakers are available with operating currents up to 8,000ADC and operating voltages up to 3600VDC. They have a very high interruption capacity combined with a current limiting characteristic.
Innovative materials, superior circuit breaking capacity and outstanding dielectric performance ensure service continuity and protection during adverse system events. The technology and quality of these circuit breakers produce high reliability, extended maintenance intervals and uncomplicated serviceability for all fixed installations
Features and Benefits
- Ratings up to 8000A and 4000 Vdc (3,600 Vdc, ANSI)
- IEC 947-2, EN50123-2, and ANSI C37.14 Certifications
- Solenoid drive (integral control unit, mechanically latched, no auxiliary power required to keep contacts closed)
- Available electrodynamic release for very high speed switching
- Two Stage contact system extends life of main contacts
- Compact, enclosed construction
- Full range of accessories, including up to 10 auxiliary contacts
Applications
- Traction power (light rail transit, tram, subway, maglev, etc.)
- Industrial plant protection (electrolysis plants, iron and steel mills, etc.)
- Mining
- Chemical, petrochemical
- Power generation
- Research/experimental (e.g., physics, particle accelerator protection)
|
|
Features and Benefits :
- Parts designed and manufactured to the original or improved specifications.
- Parts in stock for fast delivery when you need them.
- Engineering support to provide support for your specific requirements.
- Extend the service life of your equipment with Genuine GE Parts, designed by the original manufacturer assuring reliable fit and performance.
- Increase rating capacity with packaged engineered solutions.
- Save time with easy to install original parts
- On-site service installation or supervision optionally available.
Product Scope:
- MagneBlast Medium Voltage vertical lift circuit breakers.
- FK, FKD, FKA and VIB medium and high voltage outdoor distribution breakers.
- ARA generator breakers.
- ATB high Voltage transmission breakers.
- Type MC and AG dc breakers.
|
|
Siemens high-voltage circuit-breakers offer the optimum technical and economical solution for every requirement. Depending on the application and the voltage level, they are equipped with the following combinations of arc quenching principle and operating mechanism:
* Self-compression principle with stored energy spring mechanism
* Puffertype with hydraulic mechanism
All the live- and dead-tank circuit-breakers, as well as the gas-insulated switchgear (GIS), are equipped with the same components. Longevity, reliability and highest availability in all climate zones in the world distinguish Siemens high-voltage circuit-breakers from all others.
|
|
808
Single pole purely magnetic circuit breaker,
fast acting, for pcb mouting
8340-G2
Hydraulic-magnnetic circuit breaker, push-pull actuation, threadneck panel mounting
8340-G2-DC110V
Hydraulic magnetic circuit breaker with push-pull actuation for DC110V applications
8340-F
Toggle-operated hydraulic-magnetic
circuit breaker, flange mounting
8340-T
Toggle-operated hydraulic-magnetic
circuit breaker for rail mounting
8345
Toggle-operated hydraulic-magnetic circuit breaker, flange mounting, ratings up to 125 A
8345-DC110V
Toggle-operated hydraulic-magnetic circuit breaker, flange mounting, ratings up to 125 A
|
|
Typical Applications
Warn of trouble by providing an alarm output if a process signal exceeds a high or low limit.
Create an independent emergency shut-down system to avert undesirable situations in the event of central power failure or DCS shutdown.
Combination alarm trip and transmitter modules reduce costs when both alarming and monitoring functions are needed at the same location.
Sense dangerous conditions, and shut down equipment, before it is damaged.
Compare two variables and trip an alarm when the difference between the two exceeds a preset value.
Install multi-trip alarms to provide several levels of warning and shutdown actions.
Use for reliable, and cost-effective, on/off control of pumps and motors.
|
|
Description
Special technical features of live-tank design: On live-tank circuit-breakers, the interrupter chamber is arranged in the insulator which can be either porcelain or of a composite material, and is at high potential; with the voltage level determining the length of the insulators for the interrupter chamber and the insulator column.
|
|
Load break switch: switchblade with integral arc-strangler load breaking device for hinge-style mounting. This product includes a stationary core and a spring-loaded sliding sleeve which could quickly cut off the arc produced between the mounting contact and blade during load breaking operation.
Rated voltage: up to 15.5kV
Rated continuous current: up to 200A
|
|
|
GE's BreakMasterTM metal enclosed load interrupter switches provide dependable, economical load switching and protection for medium voltage circuit applications from 2.4kV through 15kV in 600 or 1200 ampere load interrupting ratings. Used mainly as a primary or secondary disconnect switch for transformers, the variety of configurations in which BreakMaster is available also make it useful for specific distribution needs. It can be inserted as a main or feeder switch in PowerVac switchgear or LimitAmp motor controller lineups. Fault current protection is available using a complete line of current limiting or expulsion fuses.
|
|
|
Ensto's family of load break switches consists of 3-pole switches with additional poles and accessories: handles, shafts, auxiliary contacts and terminal covers.
|
|
|
In application of new concept mechanism of bendable type blade structure LG Tri-MEC Air Insulited Load Break Switch (LBS) has been equipped with further advanced technology and in a system switching the circuits when checking, measuring, testing and repairing the instruments. at branch point with 3 phase load break switch designed customer-orientedly and considerably. In particular, a bendable type blade structure is significantly small in operation radius in contrast with existing direct line one and an arc discharge angle at the time of breaking operation is under 50°, thereby reducing the danger of accident by an arc remarkably. And it is suitable for a metal Enclosed, Pad-Mounted Switchgear and Package Substation thanks to higher insulation-resistant power and is equipped with durability, stability and economical efficiency. E2 class mechanical strength based on new standard application.
|
|
Disconnectors and switch-disconnectors vertical break design SBC range
Description
The disconnectors and switch-disconnectors SBC range is visible breaking, vertical break design and principally used in rural distribution networks. They are suitable for horizontal or vertical mounting on metal, concrete or wooden single or double poles.
SBC types have a load breaking head comprising a chamber and fast opening auxiliary blade.
This arrangement combines the high speed action of the auxiliary blade with the cooling and confining effect of the enclosure to restrict the arc and limit the production of gases
|
|
Yaskawa's SF6 load break switches are safer to operate than vacuum and other competitive types because the gas pressure is continuously monitored by a pressure switch and is mechanically and electrically interlocked if pressure is lowered. Highest quality porcelain bushings are used for longer and more reliable insulation performance, thus making the Yaskawa switch ideal for use in hostile and dusty environments such as mines, heavy salt-ridden coastal areas, and dense tropical areas.
Yaskawa furnishes the load break switch in three application configurations.
Pole
Pad
Submersible
|
|
|
|
|
|
General description:
EntelliGuard® G circuit breakers are the newest line of GE low-voltage circuit breakers, the next step in the evolution of a line known for its exceptional reliability and performance. They are available in 3- and 4-pole designs rated from 400A to 6000A, with fault interruption ratings up to 150kAIC
Integral to the EntelliGuard G breakers are the new, state-of-the-art EntelliGuard TU Trip Units, which provide superior system protection, system reliability, monitoring and communications.The breaker-trip unit system delivers superior circuit protection without compromising either selectivity or arc flash protection.
The EntelliGuard breaker-trip unit system demonstrates yet again GE's core competencies in reliable electric power distribution, circuit protection and personnel protection.
Modern economic reality and the regulatory environment demand system performance while recognizing the need to protect against the arc flash hazards that expose maintenance personnel to dangerous levels of heat, electrical energy, debris from damaged equipment and concussive forces. The challenge is to provide both better personnel protection by minimizing arc flash hazards and maintain electrical power to mission-critical loads. But these objectives often seem to conflict, pitting the speed and sensitivity required to optimize safety against the sequence of operations and interlocking required to maximize power system availability.
|
|
Main Circuit Breakers
100 to 225A. THQM main breakers are configured to allow top or bottom feed without modification.
Feeder Plug-in Circuit Breakers
15 to 200A. Choose from 1/2" THQP or 1" THQL & TQDL breakers with options for 1 to 3 poles. THQP breakers allow the use of smaller load centers that save money and space in both new installations and service upgrades.
Ground Fault Circuit Interrupter (GFCI)
15 to 50A. 1" THQL breakers with options for 1 or 2 poles. This GFCI circuit breaker provides protection against overloads, short circuits and ground faults.
Arc Fault Circuit Interrupter (AFCI)
Branch/Feeder AFCI - 15 to 20 amp, ½" or 1", 1 or 2 pole
Combination AFCI - 15 to 20 amp, 1", single pole
|
|
Features and Benefits:
- True closed-door drawout design
- Field-installable accessories
- One standardized wiring diagram for all breakers with dedicated secondary disconnect and breaker accessory points
- Trip unit display through the breaker escutcheon with metering and trip information
- Three choices of solid-state trips with function and cost variability:
Power+ with basic overload and short circuit protection, and optional ground fault trip target
MicroVersaTrip Plus with full range of overcurrent and ground-fault protective functions
MicroVersaTrip PM with advanced metering, communications and protective relaying options.
- Maintenance convenience and safety
- Maximum selectivity with downstream devices
- Minimum downtime
|
|
|
Terasaki has a full range of Moulded Case Circuit Breakers from 30A to 4000A, and Air Circuit Breakers from 800A to 6300 A.
|
|
|
Raychem PESD electrostatic discharge protection devices are designed for I/O port protection in high-speed data transmission applications, PESD devices shunt ESD away from sensitive circuitry in electronic devices. The PESD devices provide exceptionally low capacitance, they perform better than other comparable components in TLP (transmission line pulse) testing, as well as IEC61000-4-2 testing, especially after multiple hits (up to 1000). The devices offer a lower trigger voltage and a lower clamping voltage than typical polymer ESD (electrostatic discharge) devices, resulting in improved protection of sensitive electronic components.
|
|
|
|
|
|
Features and Benefits :
- Modular design with interchangeable footprint and parts for all breaker sizes
- Comprehensive mechanical and electrical interlocks for operating safety
- Virtually maintenance-free vacuum interrupter contacts
- Direct reading erosion indicator for vacuum interrupter contacts
- Superior vacuum interrupter technology
- Reliable, quite arc interruption
- Extensive factory testing
- Operator convenience
- Reduced maintenance required over product life
- High degree of reliability and product integrity
Product Scope:
- Modular, standardized frame size, regardless of voltage or interrupting capacity.
- Most of the frame parts, primary conductors, disconnects, and mechanisms are interchangeable throughout the breaker product line
- Can be used in systems rated 4.16kV - 250 MVA through 13.8kV - 1500 MVA at 1200, 2000, 3000, 3500, and 4000 A (in fan-cooled equipment)
- Ratings 27kV 16kA & 25kA, 1200 & 2000A are available.
- Designed and tested to all applicable ANSI, IEEE , and NEMA standards, and carry a UL and CSA label.
|
|
|
The heart of the GE PowerVac® circuit breaker is the vacuum interrupter. GE pioneered this interrupter technology beginning with experimental work in the 1920's. Today, the vacuum design remains superior to other arc interruption technologies by providing a smaller footprint and simpler design.
|
|
Application - Miniature circuit breakers ETIMAT DC are
used for protection of conductors in direct current
electric circuits. 1-pole circuit breakers are used for
voltages up to 220 V d.c.
and for higher voltages (up to 440 V d.c.) 2-pole circuit
breakers with poles connected in a series.
When connecting the MCB ETIMAT DC man must pay
attention to polarity.
If connected in a wrong way, the MCB can be destroyed.
You cannot use two 1-pole MCBs instead of one 2-pole MCB.
|
|
MCB10:1-pole
* Designated for home, commercial and industry electrical circuits up to 63A/230/400V AC
* Designated for protection of cables and wires against over-loading and short-circuit
* Possibility of connection with RCDs, unifi ed versionfor rated current in range 0.5-63A
* Indication of state of contacts marking ON/OFF on the switch
* Possibility of connection with RCB
* Possibility of auxiliary switch connection
* Possibility to mark circuits
|
|
Q-Line Miniature Circuit Breakers
15 to 100A. THQB and THQC types. Available in bolt-on and Cable-in Cable-out (lug-lug) versions.
E2000 Miniature Circuit Breakers
0.5 to 63A. These miniature circuit breakers offer superior supplemental overload and short circuit protection. The E2000 line has two levels of interruption capacity, 6 kAIC and 10 kAIC.
|
|
Field finable
accessories
J Short-circuit capacity 6kA (EN 60898)
1 Tripping characteristic
B,C,D
Application
Domestic and commercial distribution
Rated voltage: 230V / 400V-
Frequency: 50 / 60 Hz
Calibration temperature: 30°C
Terminal capacity: 35 mm2
Electrical endurance: 30,000
Mechanical endurance: 40,000
Poles: 1p 1p+N 2p 3p 3p+N 4p
Mounting: 35mm symmetrical DIN rail (EN 50022-DIN 46277)
Standards: EN 60898, EN 60947-2, EN 20317
Nominal current ratings from 0.3 to 63A
The TemDin2 range of Miniature Circuit Breakers have been designed for protection of electrical installations against overload and short circuits.
Tripping curves
The TemDin 2 series of Miniature Circuit Breakers are manufactured in accordance with EN 60898 (tripping characteristics B, C and D)
- Curve B: magnetic trip threshold = 3 - 5 In
- Curve C: magnetic trip threshold = 5 - 10 In
- Curve D: magnetic trip threshold = 10 - 20ln
|
|
Nominal current ratings from 10 to 40A
Miniature circuit breakers designed for protection of
electrical installations against overloads and short circuits
Features
- Short-circuit capacity : 6kA ( EN 60898 )
- Tripping characteristic : C
- Application : Dommestic distribution
|
|
|
|
|
|
For today's customers building machines for use throughout the world, the new Bulletin 1489 helps with compliance for the varied circuit protection requirements. The Bulletin 1489 line is listed for branch circuit applications in the United States and Canada and approved as a miniature circuit breaker for IEC applications.
Designed to meet North American and IEC standards the 1489 product line provides a variety of configurations with current ranges of 0.5 A to 40 A and voltage ranges of 240V AC and 480Y/277V AC. The 1489 circuit breakers also have a DC rating: 1-pole 48V DC and 2-pole 96V DC series. This versatility can reduce engineering costs, save time for OEMs, panel builders and end users and can help meet safety standards.
In North America, the Bulletin 1489 meets UL 489 and CSA 22.2 No. 5.1 standards for branch circuit protection as well as IEC 60 947-2 requirements for miniature circuit breakers used in international industrial applications. To address the needs of equipment protection that are installed in electrical control panels, the new device helps with the equipment protection circuit formally only associated with UL 1077. It provides users with circuit protection from 0.5 amps to 40 amps and up to 480 volts.
For ease of installation a series of 1489 busbars (80 A) are now available, certified to UL489. These busbars are available in: single phase, two phase, and three phase versions.
As circuit protection standards evolve to meet application demands, Bulletin 1489 gives users a safer, reliable option that protects personnel, equipment and facilities from electrical hazards.
|
|
|
The "Record Plus" family of circuit breakers has been developed as a line of aesthetically and technically coordinated protection devices for LV distribution and control applications.
|
|
. Types: BK series, BF series, BS series, FB series, RK series
2. Ratings
(1) Miniature Circuit Breakers
1) BK series
- BKN: 1 to 4pole up to 63A & 6kA (IEC60898)
- BKN-b: 1 to 4pole up to 63A 10kA (IEC60898)
- BKH: 1 to 4pole from 63 to 125A 10kA (IEC60947-2)
2) BF series
- 6~50A Max 2.5kA at 415VAC (IEC60947-2)
3) BS series
- 6~30A, 1.5kA at 110/220VAC
4) FB series
- 3~30A, 5~50A, 60~100A, 2.5kA at 460VAC 2, 3pole
(2) Residual Current Devices: RK series
1) RKN type (RCCB): Confirming to IEC61008, Protection against ground fault, 25~63A, 30, 100, 300mA
2) RKP type (RCBO): Confirming to IEC61009,
|
|
Modular circuit-breakers up to 63A
Description
Nominal current: 1 to 63A
Large choice of breaking capacities and tripping curves: B,C,D...
Compliance with standards: IEC EN 60898 or IEC 60947-2 depending on the version, certified by national official authorities
Suitable for isolation in accordance with industrial standards: IEC 60947
Operating voltage: up to 440 Vac, insulation voltage: 500V
Optional add-on earth leakage modules: C60 Vigi
Optional auxiliaries: indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip
|
|
|
|
|
|
Low voltage moulded case circuit breakers are used for the switching and protection of power supply cables, motors
and other electrical equipment against overloads and short circuit faults. It provides, beside protection function other
functions as remote ON/OFF operation, undervoltage protection, main switch, ...
They are available in range from 16 A up to1600 A in 3 and 4 pole versions.
Advantages:
- Small dimensions,modular sizes
- Possibility of field-instalable accessories - up to 630 AF series 2
- High short circuit breaking capacity (up to 100 kA)
- Fast break mechanism (F.B.M.)
- Reduced energy let throught I2t - minimises thermal stresses
- Reduced tripping time - minimises damage after fault
- Reduced peak short current ampacity - minimised electrodynamic stresses on conductors and
protected equipment
- Installation on mounting plate, 125 AF also on DIN-rail
- Wide range of accessories
- Compact design with high mechanical strenght
- High withstand voltages (8 kV a.c.)
- Voltage level up to 690 V a.c. and 250 V d.c. - only MCCB's with thermal-magnetic triping unit
- Direct opening - recommendation according to standard IEC 60204-1 - up to 630 AF series 2
- Common internal accessories - up to 630 AF series 2
- Visual safety
- Unsurpassed flexibility
|
|
|
|