Breaking Contacts
TemPower 2 is the world's first Double Break ACB, having two breaking contacts per phase. The unique pole structure means that the short-time withstand rating (Icw) is equal to the service short-circuit breaking capacity (Ics) for all models.
Packing Density
You can increase switchboard packing density using the smallest one second rated ACB on the market. The fixed version is 290mm deep, the drawout version is 345mm deep.
Reliability
Double Break contacts increase service life. Electrical and mechanical endurance ratings are the best available, and exceed the requirements of IEC 60 947-2.
Double Quick Opening
TemPower 2 ACBs clear short-circuit faults in less than 30ms. That%u2019s twice as fast as most ACBs.
Double Opening and Closing Coils
Now you can extend control system redundancy to an ACB. Double coils allow designers to implement back-up tripping and closing systems.
Double Neutrals
How do you make a system harmonic proof in the face of increasing triple-N harmonic currents? Terasaki have launched the first Double Neutral ACB. The AH-60DN will carry 10,000A of neutral current.
Protection Characteristics
TemPower 2 is the only ACB which offers time-current characteristics to 3 different standards:
IEC 60 947-2 (low voltage circuit breakers)
IEC 60 255-3 (electrical relays)
Lloyds Register of Shipping (for marine generator protection)
All models have LSI protection.
Double Insulation Properties
All operator controls and accessory locations are double insulated from the main phases.
ReduceTime to Repair
Modular construction means that each pole of the TemPower 2 ACB can be replaced in about 15 minutes - by the user. This unique feature will reduce downtime for end-users.
|
|
High breaking capacity
- LS Ace-MEC ACE provides high breaking capacity up to 100kA
Various certification and approval
- LG Ace-MEC ACB is type-tested by IEC 60947 and GB 14048-2-94 standard
- KEMA (Netherlands), ESI (Italy), CCC (China), KERI (Korea), ISO 9001, ISO 14001
Compact & Modular design
- More compact overall dimensions and light weights.
- LG Ace-MEC ACB have been made three types of modular design criteria to facilitate their installation and
integration in low voltage switch boards.
|
|
630 to 1600 A hight current circuit-breakers
Description
Nominal current:630 to 1600 A
Breaking performance:42 to 150 kA at 220/415 V AC
Voltage rating:up to 690 V
1 single physical size from 630 to 1600 A
A single pole pitch of 70 mm
3 and 4-pole versions
4 Micrologic control units enriched by measurement, energy management and network analysis functions
Earth leakage protection built into electronic protection
Wide range of common auxiliaries and accessories interchangeable on site
Compliance with international standards IEC 60947-1 and 2, IEC 68230 for type 2 tropicalisation, UL489, ANSI and CCC
Compliance with specifications of marine classification companies:Bureau Veritas, Lloyd’s Register of Shipping, Det Norske Veritas, etc.
|
|
Terasaki developed its original breaker for the first time in Japan in 1947.
Since then, the company has been offering, as a specialized breaker
manufacturer, the most advanced breakers not only to the Japanese market, but
also to the world markets.
The TemBreak series of Moulded case circuit breakers, which is evaluated as
highly reliable by our customers, has been improved from time to time for better
performance through Terasaki's advanced technologies.
In 2000, the TemPower 2 series was released to replace the Tempower series of
air circuit breakers, which had received high reputations for many years. This
new series consists of small, high-performance air circuit breakers featuring
advanced information and communication capabilities.
Terasaki is ready to meet the customers' requirements in the 21st century through
its diversified model lineup and its broad range of enhanced products.
|
|
Application:
Miniature circuit breakers ETIMAT DC are used for protection of conductors in direct current
electric circuits. 1-pole circuit breakers are used for voltages up to 220 V d.c. and for higher voltages (up to
440 V d.c.) 2-pole circuit breakers with poles connected in a series. When connecting the MCB ETIMAT DC
man must pay attention to polarity. If connected in a wrong way, the MCB can be destroyed. You cannot use
two 1-pole MCBs instead of one 2-pole MCB.
|
|
MOTOR PROTECTION CIRCUIT BREAKERS
- Wide adjustment range, 0.1 to 100A
- Breaking capacity Icu 50kA at 400V, up to 100A
- Suitable for isolation
- Comprehensive line of accessories
- Front mount contacts
- Automatic trip indicators
- High reliability and accuracy of tripping.
SWITCH DISCONNECTORS
- 16A to 1250A ratings
- Versions: direct operating handle, door coupling and in housing
- Wide range of accessories
- Three and four-pole types for photovoltaic applications up to 630A.
ROTARY CAM SWITCHES
- Wide range, 12 to 125A
- Suitable for circuit connection, changeover, switching
on and off, and motor starting
- Custom-made circuit schemes
- IP40 and IP65 front degree of protection
- 2 screw fixing
- Numerous types of features
- Approved by major international authorities.
|
|
A complete range of products, from infeed to branch
Mitsubishi Electric offers a complete range of switchgear products, including everything from air circuit breakers and compact moulded case circuit breakers to magnetic contactors and thermal overload relays. Standardised chasses, high reliability, simple installation, easy operation and trouble-free upgrading are just some of the outstanding features.
Mitsubishi circuit breakers and contactors conform to all major international industrial standards and shipping classifications. And they also are particularly attractive. For example, our Super AE series of air circuit breakers won the prestigious Industrieforum Design award for product design.
Air circuit breakers
• Super AE air circuit series
• Standard SW series
• High-performance SH series
Moulded-case circuit breakers
• WWS World Super Series
Magnetic contactors and thermal overload relays
• MS-N series
Motor protective circuit breakers
• M4 series
|
|
Overview:
Choose 1" THQL breakers or GE's exclusive 1/2" THQP circuit breakers (THQP are available for most load centers). Both are superior products and because the compact THQPs make the most of available panel space, you can install smaller load centers to save money and space in both new installations and service upgrades.
Features and Benefits
- 1"or 1/2" breaker sizes available
- Copper to copper connections, with corrosion-resisting tin plated stabs
- Every breaker exceeds UL, NEMA, ANSI, CSA requirements
- 65° C/75° C Conductor Rating
- Quick make/Quick break box type terminals
- Handle trips to center position, giving a clear indication of a tripped breaker
- Multi pole circuit breakers incorporate internal common trip
|
|
Hitachi Mould Case Circuit Breaker ( Fuse-Free Breakers ) & Earth Leakage Breakers are designed for circuit protection of low-voltage distribution systems. They are suitable for applications as main breakers, protection of branch, feeder circuits and connected apapratus.
Quick contact inspection/ Easy contact replacement.
Easy wiring/ High safety/ High Reliability.
DIN rail mounting mechanism.
|
|
|
Circuit breakers offer circuit protection, which is far superior to fuses in applications containing relay circuits, motors, heaters, transformers, solenoids and semiconductors.
|
|
|
Circuit breakers offer circuit protection, which is far superior to fuses in applications containing relay circuits, motors, heaters, transformers, solenoids and semiconductors.
|
|
- No minimum order quantities
- Same day shipment on in-stock products
|
|
Switching, Protection, Communication – Circuit-Breakers and Switch-Disconnectors up to 1600 A
It has arrived, our new homogenous circuit-breaker series
The Moeller principle of innovation and future security of investment has been implemented by the new circuit-breaker series up to 1600 A.
Four switches with four levels of switching capacity
Four switches with four universal levels of switching capacity form a comprehensive range, from the competitively priced 25 kA for small sub-distribution boards, up to 150 kA switching capacity for complex high-power systems. The compact construction of the new small 160 A switch saves space as a main switch in machine control schemes, as an incomer in service distribution boards or as an outgoer in power distribution boards. Additional device levels are 300 A, the particularly compact 630 A, and the large 1600 A circuit-breaker.
|
|
Using a bimetal, snap–acting disc as the sensing and actuating element, the Klixon® C Series thermal circuit breaker provides trouble free over–current protection for harsh environments.
Applications Accessory and equipment protection for heavy trucks, buses, construction equipment, off–road vehicles, RV’s Battery protection in electric vehicles
|
|
Bulletin 1492-MC Circuit Breakers
Industrial Circuit Breakers for North American Applications
The Bulletin 1492-MC line includes:
1/2 in. wide circuit breakers
1 in. wide circuit breakers
Ground Fault Circuit Interrupters (GFCIs)
Ground Fault Equipment Protector (GFEPs)
Bulletin 1489 Circuit Breakers
Industrial Circuit Breakers for North American Applications
The Bulletin 1489 line includes:
UL 489, CSA 22.2 No. 5.1
240V AC 0.5...40 A
1-pole 48V DC 0.5%u202640A
480V/277V AC 0.5...25 A
2-pole (series) 96V DC 0.5%u202640A
Miniature Circuit Breaker for IEC Applications EN 60 947-2
415V AC 0.5...40 A
48V DC 0.5%u202640 A
|
|
Mitsubishi Electric offers a complete range of switchgear products, including everything from air circuit breakers and compact moulded case circuit breakers to magnetic contactors and thermal overload relays. Standardised chasses, high reliability, simple installation, easy operation and trouble-free upgrading are just some of the outstanding features.
Mitsubishi circuit breakers and contactors conform to all major international industrial standards and shipping classifications. And they also are particularly attractive. For example, our Super AE series of air circuit breakers won the prestigious Industrieforum Design award for product design.
|
|
|
If a magnetic relay coil is opened and closed near an electronic circuit, malfunctioning of the electronic circuit could be induced by a surge voltage. The UN-SA type surge absorber suppresses the surge voltage when the coil is opened and closed. In addition to the general varistor type and the CR type that lays importance on suppressing the induction voltage when starting, the type with operating indicator (varistor type), and the varistor type with CR are available.
|
|
No electrical system can do without circuit breakers, as they are the 'stop' signs acting when too much current is flowing through electrical wiring.
In fact, they are essential devices and one of the most important safety mechanisms for the prevention of dangerous situations. The value of circuit breakers depends on which appliances are connected. You can either order a ready-made switchboard with the most common circuit breaker values, or give the installer or distributor a list of your specific values for a tailor-made solution.
|
|
Circuit breakers offer circuit protection, which is far superior to fuses in applications containing relay circuits, motors, heaters, transformers, solenoids and semiconductors.
NRA Series
Dual mounting (panel mount or socket mount) circuit breakers with a variety of actuator styles and current rantings up to 30A. Available in 1, 2 or 3 poles; standard and motor time delay curves.
NRB Series
Panel mounting circuit breakers with stud terminals and current ratings up to 50A. Available in 1, 2 or 3 poles; standard and motor time delay curves.
NRC Series
DIN rail mountable circuit breakers with screw terminals and ratings up to 30A. Available in 1 or 2 poles; standard and electronic time delay curves.
|
|
|
Yaskawa SF6 gas rotary-arc circuit breakers are rated for applications in power generating plants, substations, and industrial plants at 3.6kV to 15kV. Yaskawa SF6 gas rotary-arc circuit breakers are safer to operate than vacuum and other competitive types because a two-stage pressure switch in each of the interrupters continuously monitors the gas pressure. This series of Yaskawa SF6 gas rotary-arc circuit breakers offer excellent interrupting characteristics, comparable to air-magnetic breakers, with continuous current ranging from 600 to 3000 amps. In addition, the surgeless nature of the current interruption eliminates the need for surge arrestors to dampen voltage spikes related to current chopping and switching surges. This feature makes the Yaskawa SF6 gas rotary-arc circuit breakers ideal for the protection of motors, capacitors, and transformers. This series of circuit breakers conforms to applicable ANSI, IEC and JEC st
|
|
DataLinx - Category 5e / T1 Protected Patch Panels
12 Port Protected Patch Panel, CAT5/5E and T-1 rated, 110 and RJ45 I/O, UL Listed for Primary, Secondary and Isolated Loop, fits 19
|
|
Description
Special technical features of dead-tank design. The distinguishing feature of dead-tank technology is that the interrupter chamber is accommodated in an earthed metal housing. With this arrangement the SF6 gas filling insulates the high voltage live parts of the contact assembly from the housing. Outdoor bushings connect the interrupter chamber with the high-voltage terminals.
|
|
Electronic Overcurrent Protection
ESS1
Electronic circuit breaker (DC 24 V, max. 6 A), with physical isolation, LED status indication
SVS1
Modular power distribution system for ESS1; 4, 8, 12, 16 positions
ESS20-0..
Electronic circuit breaker (DC 24 V, max. 10 A), with physical isolation, 1 LED
Module 17plus-ESS20-0
Modular power distribution system for ESS20-0, two-way, track-mountable
ESS20-1
Electronic circuit breaker (DC 24 V, max. 10 A), with reset input, 1 LED
Module 17plus-ESS20-1
Modular power distribution system for ESS20-1, two-way, track-mountable
ESX10
Electronic circuit protector DC 24 V, max. 12 A, electr. disconnection 1 LED, reset input, status output
Module 17plus-ESX10
Modular power distribution system for electronic circuit protector ESX10
ESS60T
Electronic circuit breaker (DC -48 V, max. 60 A) with serial interface, 1 LED
|
|
CIRCUIT BREAKERS FOR EQUIPMENT:
THERMAL:
SCHURTER's Thermal Circuit Breakers are designed for use in electrical and electronic equipment. They meet international safety standards. One-, two-, and three-pole types are available with different actuation and mounting styles.
THERMAL-MAGNETIC:
SCHURTER's Thermal-magnetic Circuit Breakers are designed for use in electrical and electronic equipment. They meet international safety standards. One-, two, three- and four-pole types are available with lever actuation for different mounting styles.
UNDERVOLTAGE PROTECTION:
SCHURTER Undervoltage Protection units meet international safety standards. Available current ratings range from 2.5 Amps to 20 Amps, for snap-in mounting.
POWER ENTRY MODULES WITH CIRCUIT BREAKER:
SCHURTER's Power Entry Modules with built-in Circuit Breakers meet international safety standards. Available current ratings range from 2.5 Amps to 20 Amps, for screw-in, snap-in, and PCB mounting.
|
|
Short description :
Provide personal protection from ground faults and open neutral conditions anywhere electrical equipment is used. Ptortection for the job site, plant floor or workshop. Each product is UL Listed and meets OSHA specifications.
|
|
The National Electrical Code requires GFCI protection of receptacles located outdoors and in bathrooms, garages and spa areas. This GFCI circuit breaker provides protection against overloads, short circuits and ground faults. It detects very low levels of electrical current leaks (ground faults), and acts quickly to shut off power, preventing serious shock.
Features and Benefits
* UL Listed (Molded Case Circuit Breakers No. 489 and Ground Fault Circuit Interrupters No. 943).
* Class A (.005 ampere ground fault trip level).
* Available from 15-30 Amps 1 Pole, 15-50A 2 Pole.
* Voltage is 120 and 240 volt ratings
|
|
Hitachi Mould Case Circuit Breaker ( Fuse-Free Breakers ) & Earth Leakage Breakers are designed for circuit protection of low-voltage distribution systems. They are suitable for applications as main breakers, protection of branch, feeder circuits and connected apapratus.
Quick contact inspection/ Easy contact replacement.
Easy wiring/ High safety/ High Reliability.
DIN rail mounting mechanism.
|
|
- Protection against overload, short-circuit and ground fault.
- Offering economical solution with compact and increased interrupting
capacities.
- Employing a fixed thermal and fixed magnetic trip.
- Frames made of rigid materials of engineering plastics
- Offering the physically same size with MCCBs.
|
|
|
|
|
|
With the CT contactor series Schaltbau is introducing a new and innovative contactor concept to the market: power contactors in a completely new style and design, specially developed for the sophisticated requirements of the railway industry. The outstanding technical feature of this new product is the innovative combination of electromagnetic and permanent-magnetic blowout technology for electric arc control. The successful combination of these two principles greatly improves both switching functionality and reliability and forms a practical and economically impressive device concept.
The innovative core of the new CT series is the electric arc control technology: in contrast to contactor concepts purely based on electromagnetic blowout, the arcs created at the moment of switching off are ignited in powerful permanent-magnetic blowout fields. Thus the dwell periods in the contact zones are limited to an absolute minimum. This leads to a significant reduction in arc-related burn-up when switching off. The lower degree of wear on the contacts makes it possible to greatly increase maintenance intervals.
The arcs blown out of the contact zones act as wear-free switches in the next phase: the skipping to adjacent arc modulators activates the blowout coils, making switching-off procedures independent of the direction of the current from that moment onwards. In the final phase the arcs pass through an arc chute, are stretched across the divergently arranged modulators and then effectively extinguished in a ceramic chamber. The special design of the extinguishing process reduces the discharge of ionised gases from the arc chute.
|
|
|
|
|
|
Over the past century, GE has designed and manufactured literally tens of thousands of medium and high voltage circuit breakers. Although many of the older designs are no longer manufactured, many units remain in service. GE can deliver solutions for these breakers without the cost and downtime associated with complete equipment replacement. If you have any of the following breakers in service, we can provide parts or engineered solutions to support your maintenance needs:
Features and Benefits
* Parts designed and manufactured to the original or improved specifications.
* Parts in stock for fast delivery when you need them.
* Engineering support to provide support for your specific requirements.
* Extend the service life of your equipment with Genuine GE Parts, designed by the original manufacturer assuring reliable fit and performance.
* Increase rating capacity with packaged engineered solutions.
* Save time with easy to install original parts
* On-site service installation or supervision optionally available.
|
|
|
|