The Rapidox 3100 provides fast and accurate analysis over a wide oxygen range using a rugged, long-life zirconia sensor. It is available in models to measure just oxygen, or oxygen plus either CO or CO2.
Easy to use and simple to calibrate using your choice of any two gases, the Rapidox 3100 offers the high performance and flexibility usually found only in much more expensive products.
The Rapidox 3100 incorporates a powerful and silent linear piston pump for remote sampling of gas. From the display to the outputs, all features are fully programmable using the keypad on the front panel. Connections are made using 6/4mm flexible tubing to the front panel input and output unions and the front panel includes a flow gauge allowing the user to control the rate of gas flow into the analyser.
The Rapidox is supplied with powerful Windows software for easy data-logging and graphing. Just switch on and start measuring...
- Bench mounted zirconia oxygen analyser with internal sensor & sample pump
- Rapid response long-life sensor
- Easy to calibrate using any two gases
- Fully programmable audible alarms with signal output
- Sample flow rate adjustable from 0 to 4 litres per minute
- Suitable for applications where the gas must be sampled remotely
- Gas is sampled through flexible tubing connected to the front of the analyser
- Perfect for analysis of room air and difficult to access locations
- Perfect for static gas applications
- Suitable for gases up to 150°C
|
|
|
Reliable measurement of ppm combustibles (CO + H2) or carbon monoxide (CO) together with oxygen, allows the user to determine and maintain the optimal O2 set point for the process. This results in improved product throughput, increased safety, longer equipment life, lower emissions and maximized fuel efficiency.
|
|
The analyser ARELCO ARC model 2008 IR MP-R is a compact and reliable instrument for specific measurement of CO2 or CO or CH4 in gas blending. The instrument is based on non dispersion infra red method (NDIR)
The touch sensitive display allow the user to see very quickly all parameters: gas contents, analogue output range, alarms status… and to get access to the menus.
The 2008 IR MP-R model is 19” rack type and integrates some data storing facilities, automatic calibration function. All data are available on digital interface RS232.
The IR technology requires a dry gas. The instrument could be couple to a gas dryer and speciel filter especially for measurement on flue gases.
|
|
KIMO, French manufacturer of measuring instruments, designed and developed AQ100 to meet with requirements of new regulations on CO2 air detection.
Key features of AQ100: easy and friendly use, large display, accurate measurements, CO2 / temperature probe.
- CO2 : from 0 to 5,000 ppm
- temperature (integrated inside the probe) : from –20 to +80°C
AQ100 is supplied with calibration certificate.
|
|
|
|
|
|
Q-TRAK™ Indoor Air Quality Monitor
Model 7565
Providing a comfortable, safe and healthy indoor environment is an increasingly important concern. Good air quality increases concentration and productivity. It can also reduce lost days due to absence. TSI’s Q-TRAK IAQ Monitor provides quick, accurate information to assess key IAQ parameters.
Features and Benefits
• Measures CO2, temperature, humidity, and CO
• Calculates dew point, wet bulb and percent outside air
• Displays up to 5 measurements simultaneously
• One instrument with multiple plug-in probe options
• User-selectable logging intervals and start/stop times
• Store up to 38.9 days of data collected at one-minute log intervals
• TRAKPRO™ software provided for data logging, analysis and documenting results
- Perform single-point tests for quick building surveys
Easy to Use
The Q-TRAK features a menu-driven user interface for easy operation. On-screen prompts and step-by-step instructions guide the user through operation and field calibration. The Q-TRAK also features an ergonomic, overmolded case design and a keypad lockout to prevent tampering during unattended use.
|
|
FireBoss 100 Carbon Monoxide Sensor
FireBoss 100 Carbon Monoxide Sensor -All CO sensors are not alike. The FireBoss toxic 0-25-100-500 ppm CO sensor line has been re-designed and enhanced over a period of two decades of underground mining use, and has evolved as a tough, dependable product with exceptionally long-term stability. Others are often plagued with temperature problems and short life expectancy. We frequently observe sensors still working on their first electrochemical cell after 5- 8 years of grueling service.
|
|
|
The 300 Series of analyzers use the Gas Filter Correlation (GFC) NDIR technique to measure trace level and stack level concentrations of CO, CO2, and N2O. The GFC technique rejects potential interferents, such as water, and allows unprecidented sensitivity. From background monitoring to air separation, the 300 Series is the best value for precision IR monitoring.
|
|
The CO-measuring system was developed according EU regulations for controlling the concentration of the limit values of carbon monoxide (CO) and nitrogen (NO) if applicable.
The warning-system can be connected to the tunnel DCS.
|
|
|
|
|
|
The new Serinus 10 Ozone (O3) analyzer is the next generation in
gas monitoring technology.
The Serinus 10 Ozone analyzer uses proven non-dispersive
ultraviolet (UV) absorption technology to measure O3 in ambient air
(LDL <0.5ppb, Range 0-20ppm). Combining several new technical
advances and innovative features, the Serinus delivers Ecotech’s
renowned performance and excellent value.
Superior performance
• U.S. EPA approved
• New zero volume fittings and flexible Teflon® tubing improves system integrity
• Advanced diagnostics and status indicator deliver better instrument status information
• New removable flash memory stores eight years of data, including up to 16 individual parameters and event logs
Lower Cost of Ownership
• More affordable to purchase, operate and maintain
• Utilises low cost consumables, spare parts and accessories
• Reduced power usage and a lower carbon footprint
Reduced Maintenance
• Remote diagnostics and maintenance functions including calibration, parameter set-up, operational status etc.
• Standardised components reduces the cost of spare parts, accessories and consumable items
• New “dual particulate filter” can reduce scheduled maintenance calls by up to 50%
|
|
|
The HORIBA Advantage combines advanced combustion technology with a unique, patented design. HORIBA first introduced analyzers for emission and air monitoring in 1964. Today, HORIBA Jobin Yvon is the only company that offers the experience of HORIBA combustion analyzer technology and over 180 years of expertise and experience in optics and spectroscopy.
|
|
KIMO, French manufacturer of measuring instruments, designed and developed AQ200 for CO/CO2, hygrometry, temperature and pressure control.
Key features of AQ200 :
- easy and friendly use: large display, browsing joystick
- multi-probe innovating system: can be used with 3 probes :
- CO / temperature: from 0 to 1,000 ppm and from -20 to +80°C
- CO2 / temperature: from 0 to 5,000 ppm and from -20 to +80°C
- CO2 / temperature / hygrometry: from 0 to 5,000 ppm, from -20 to +80°C, from 5 to 95%RH
- 3 interchangeable measuring modules: individually calibrated and automatically recognized by the instrument :
- 1 climatic conditions module (hygrometry, air pressure and temperature)
- 1 thermocouple temperature module (4 channels)
- 1 current / voltage module
AQ200 can measure and store up to 8,000 values, which can be saved on your PC, via wireless communication system.
|
|
| ... products without technical information |
| |
Simple! Accurate! Diversified! water analysis with Single Beam UV/VIS Spectrophotometer!
Specifications
Optical System Single Beam
Spectral Band
Pass Width < 1.0nm
Wavelength
Range 190nm ~ 1100nm
Accuracy < ± 0.5nm
Reproducibility < ± 0.1nm
Setting < ± 0.1nm
Slew Rate about 5000nm/min
Scanning Speed Max. 1000nm/min
Photometric
Range -0.1 to 3.0A, 0 to 125%T
Accuracy < 1% at 1A
Reproducibility ± 0.001A
Stray Light 0.05 %T at 220 & 340 nm
Baseline Stability < ± 0.001 ABS/h (at 550nm)
Baseline Flatness < ± 0.001 ABS (200~1000nm)
Noise Level < 0.001A
Drift 0.002A/hr at 340 nm
Monochomater Modified Czerny-turner type With 1200 lines/mm Blazed grating
Light Source Tungsten and Halogen lamp and Deuterium lamp
Lamp Change Wavelength 340nm~410nm (Default 370nm)
Standard Cell Holder Automatic Rotary type 8-position Multi-Cell Holder
Interface Ports RS-232C Serial and Centronics ports
Power Requirement AC 220V, 50/60Hz
Overall
Dimensions(mm) 515(W)x430(D)x242(H)mm
Weight 16kg
|
|
The low level phosphate ion analyzer, model 7121, is used for online measurement of phosphate ion concentration in the boiler water, etc., of thermal power plants.
* Measurement time as short as 5 minutes
* Concentrations are output for each sample point separately, or those at all the sample points may be output together.
* If there is no sample at a sample point, the analyzer automatically skips to the next sample point.
|
|
|
To continuously variate radiant rays over a broad range, the specifically designed monochrometer was built in OPTIZEN 1412V OX. The monochrometer built in OPTIZEN 1412V OX, which is designed for protection from dust or corrosive steam in a laboratory, guarantees faster quantitative analysis and high preciston of analysis values. It is gaining reliability for its relatively high reproducibility of about 1 % for the amount present under ideal conditions.
|
|
|
|