- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Differential pressure flow meter
Differential pressure flow meters
Derivative of our proven Production Line Flow Meter Built-in automatic pressure control Direct correlation to harmonised standards Product specific parameters for optimum test set-up Case ...
Furness Controls
Volumetric flow rate: 0 l/min - 20,000 l/min
... FCO752 is quite possibly the most flexible, reliable, and diverse flow meter available today. Air and gas flows from 0.01 ml/min to 10,000 l/min Using Furness Controls Laminar flow ...
Furness Controls
Volumetric flow rate: 0 l/min - 10,000 l/min
Precision: 1 %
... conditions Pressure control Capable of pressure ranges up to 14 bar, the FCO732 is fitted with a precision regulator capable of controlling and supplying the correct pressure ...
Furness Controls
... the inlet contour matches that of the ISA 1932 flow nozzle. The major advantage of the Venturi over orifice plates and flow nozzles is in the area of pressure recovery. Typically, ...
The High Beta® Process (HBP) Flow Conditioner represents a proprietary-designed flow conditioning unit mainly intended for the removal of cyclonic, turbulent and reverse flow, with minimum ...
Eastern Instruments
... air flow measurement pitots for accurate air flow measurement. The DSV can be installed in either new duct work or retrofitted into your existing duct work and is perfect for ...
Eastern Instruments
Process temperature: -40 °F - 900 °F
Process pressure: -6 psi - 6 psi
... Rectangular ducts, is a pre-assembled, bolt-in assembly that contains an array of air flow measurement pitots for accurate air flow measurement. The DSV can be installed ...
Eastern Instruments
Volumetric flow rate: 0.6 m³/h - 18,000 m³/h
Process temperature: 0 °C - 60 °C
Process pressure: 10 bar
... . The meter can also be used for flow monitoring if fitted with optional limit contacts. Areas of application: The N4 orifice flow meter is used to measure the flow ...
MECON
Process pressure: 70,000 Pa - 130,000 Pa
The model 6700 is a handheld micromanometer with Bluetooth® wireless capability; it takes airflow and pressure readings with a pitot tube or the optional velocity grid. The grid is a cross shaped grid, similar to the ...
Process temperature: -20 °C - 60 °C
Process pressure: 10,000 Pa
APPLICATION One instrument for measurement of pressure, air flow, temperature and relative humidity Is tested to comply with standards for ’Ventilation for buildings – test procedures & measuring methods ...
Volumetric flow rate: 2 m³/h - 20,000 m³/h
Process temperature: -50 °C - 300 °C
Process pressure: 0 bar - 15 bar
... Orifice plate mounted between flanges Flowmeter fittings threaded, flanged or solvent weld socket Pressure inlets ¾” BSP Materials EN 1.4404 (SS 316L), PVC, PP, … others on request Options 1 ...
Process temperature: 0 °C - 113 °C
Process pressure: 0 bar - 34.47 bar
... PG-8 Differential Pressure Meters are kits designed to measure differential pressures on flow measurement valves and flow measurement ...
Process temperature: 40 °C - 70 °C
NIR watercut probe A WLR sensor based on optical spectroscopy, ideal for applications in which a superior accuracy on the water cut is needed and applications with changing water salinity.
Volumetric flow rate: 0 m³/h - 3,000,000 m³/h
Process temperature: -20 °C - 850 °C
For continuous volume flow measurement in dry gases. Reliable, even under extreme operating conditions. FEATURES Continuous measurement of velocity and volume flow Double-sided ...
Process temperature: 0 °C - 71 °C
... and uses a differential pressure transducer to measure the level of the flow stream. The 6712 Sampler then converts this depth measurement into flow rate. The probe's venting system automatically ...
Process temperature: -55 °C - 150 °C
Precision: 0.5, 0.2 %
The Multiphase liquid digital flow meter that integrates differential pressure, pressure, flow and temperature. Its multi-function monitoring ...
Process temperature: 0 °C - 40 °C
Process pressure: 0 bar - 1.96 bar
The FX Series gravity flow detectors employ a precision differential pressure transducer to detect liquid level variations in a measuring cylinder. The detectors are capable of measuring ...
Process temperature: -200 °C - 1,240 °C
Process pressure: 0 bar - 690 bar
Precision: 1, 0.5 %
... even under extreme conditions. Averaging pitot tubes are causing the lowest pressure loss of all dp-flow meters and are therefore highly energy efficient. The deltaflow has been installed ...
systec Controls
Volumetric flow rate: 15 m³/h - 12,000 m³/h
Process temperature: -15 °C - 70 °C
Precision: 0.3 %
... calculating the flow rate calculation. Auto ranging function In differential pressure type flowmeters, the instantaneous flow rate range needs to be set by calculating ...
Azbil
Volumetric flow rate: 0 m³/h - 200,000 m³/h
Process temperature: -20 °C - 50 °C
Process pressure: 2,000 Pa
... measurement probe. Usage The DPT-Flow-Batt is an on-site display designed for air handling units to measure the air flow on centrifugal fans. The DPT-Flow-Batt can also be used in ...
Process temperature: -50 °C - 500 °C
Process pressure: 25, 100 bar
Precision: 1 %
... -term accuracy. There are many types of differential pressure transmitters to choose from, such as APT9000, APT9500, APT9600. Due to the function of temperature and pressure compensation, ...
Process temperature: -20 °C - 40 °C
Process pressure: 0 Pa - 2,500 Pa
... velocity, temperature and pressure point-by-point. In accordance with UNI EN 13284, ISO 9096, UNI 10169, USEPA M2. Main Characteristics: · USB interface to download data. · Graphic interface is highly intuitive and simple. · ...
... Series intelligence Flow Integrating Instruments applies to match with many kinds of flow meter sensor or transmitter for display or integrating signals of flow, temperature, ...
... When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by ...
Flowtech Measuring Instruments Pvt. Ltd.
Process temperature: 32 °F - 150 °F
Process pressure: 5 psi - 80 psi
Precision: 4 %
FURNACEMETER™ FLOW METER DIFFERENTIAL PRESSURE FLOW METER The FurnaceMeter™ represents a full range of precision flow ...
United Process Controls GmbH
Process temperature: -20 °C - 450 °C
Process pressure: 1.6 MPa - 4 MPa
Precision: 1, 1.5, 2.5 %
... after the compression or expansion calculation is performed one by one, achieving complete real-time linear compensation, and this performance has reached the world's leading level. The differential ...
Process temperature: 500 °C
Process pressure: 600,000 Pa - 42,000,000 Pa
LG Venturi Flow Meters Flow element, also known as differential pressure flow meter, consists of a primary detection ...
Volumetric flow rate: 0.5 l/h - 500 l/h
Process temperature: -40 °C - 85 °C
Process pressure: 25 bar
... is a fuel temperature sensor installed. Delta flowmeters are pre-calibrated for differential application. Thereby Delta flowmeters can provide accurate results in any mode of engine operation. Flow ...
Mass flow rate: 7 kg/h - 4,000 kg/h
This high-speed exhaust flowmeter samples the four differential pressure transducers at up to 2500 Hz, accurately capturing every forward and reverse flow pulsation from ...
Your suggestions for improvement:
Receive updates on this section every two weeks.