| The RNG Series meter is an insertion-style gas flow meter designed to offer high accuracy measurements over an extremely large flow range. The meter has no moving parts and is virtually maintenance-free once installed. The RNG series is suitable for most gas types, including compressed air, natural gas and wet or "biogas" applications. All meters in this series are loop-powered devices with standard HART® communications for ease of field programming and system integration. Through the use of an internal RTD and an external pressure sensor (optional), the flow meter software will compensate for changes in pressure and temperature, to achieve an accurate mass flow measurement. |
|
measuring tube inside diameter: 9.7 mm; 18.2 mm; 25 mm; 32 mm; 40 mm; 50 mm ...
alternative forms of connection depending on inside diameter of measuring tube:
tube fittings; cutting ring fittings; flange connection;
flat tube ends; internal screw thread for connecting nipples
alternatively with / without input / output section
initial smallest measurable flow rate dependent on type of vane wheel: in gases from 0.08 m³/h,
in liquids 0.007 m³/h
terminal flow rate dependent on type of vane wheel: in gases 20 m/s; 40 m/s; 80 m/s;120 m/s;
in liquids: 3 m/s; 7.5 m/s; 10 m/s
working temperature range: -20° C... 100 °C; -20 °C... 240 °C and above
maximum working pressure: up to 25 bar above atmospheric
materials: stainless steel; PVDF; aluminium ...
explosion-proof type of protection: Category 1G and 1D Zone 0 and Zone 20; Category 2G and 2D Zone 1 and Zone 21
special designs on request
|
|
AALBORG®'s VORTEX METERS for steam, liquid, and gas applications have no moving parts to wear or fail. In-line (WAFER or FLANGE mounting) and INSERTION (fixed or retractable) models need less maintenance. Unique dual signal processing technology independently measures each vortex, filters out non-flow noise, and increases accuracy and turndown.
PRINCIPLES OF OPERATION:
Vortices are created when a fluid passes around a bluff
body as shown below. Vortices are alternately shed on each
side of the body, 180 degrees out of phase to each other,
resulting in an oscillating pressure gradient. As flow increases
the frequency of vortices increases in proportion to the
increased flow thereby creating a linear relationship.
BENEFITS:
RELIABLE: Electronics can be remote mounted.
No fluid-to-sensor contact.
No holes to clog.
WIDE RANGEABILITY: High flow turndown ratio up to 80:1.
HIGH ACCURACY: ±0.5% of rate.
INCREASED NOISE CANCELLATION: Non-flow noise filtered out. |
|
for temperatures from -20...+430°C (-4...806°F) and pressure
up to 100 bar (1450 psig)
non-contact measurement, no mechanically moving sensor parts, maintenance-free
suitable for vertical or horizontal installation
compact and remote electronics (up to 15 m / 50 ft) versions available
flange version DN 15 - DN 300
sandwich version DN 15 - DN 200 in stainless steel or Hastelloy C, low sensitivity to pipework noise and conditions
communication via HART-Protocol
|
|
| Racine Vortex offers high-accuracy vortex-shedding flow meters for a number of liquids and gases. Meters are available in wafer (in-line, 1/2" to 4" line size) or insertion styles (4" line size and higher). Vortex sheding technology contians no moving parts, and th meters are virtually maintenance-free once installed. Loop-powered gas flow meters offer HART communications, temperature compensaiton for mass flow measurement, CE-mark and optional ATEX hazardous area certification. Liquid flow meters also carry the CE mark. |
|
For years, Vortex Shedding Technology has been a economical and reliable (no moving parts) way to measure liquids, steam and constant density gas flows. Sierra's Volumetric Vortex product line features an inline version, the Model 220 Innova-Flo® and a unique insertion version, the Model 221 Innova-Flo®. The Model 220 is an accurate, repeatable, rugged and reliable volumetric flow meter that provides an economical way to monitor liquid flows, steam or constant density gases, product accuracy is ± 0.7% of rate for liquids and ±1.0% of rate for gases and steam over a 30:1 range. The insertion Model 221 can be made for pipe sizes up to 72 inches and has an accuracy is ± 1.2% of rate for liquids and ±1.5% of rate for gases and steam over a 30:1 range. When you need to economically and reliably measure liquid flows, think Innova-Flo®!
UNIQUE PRODUCT FEATURES
- Volumetric flow monitoring of most gases, liquids and steam
- Rangeable down to Reynold's number of 5000
- In-line sizes from 1/4 " to 8"
- 1% rate accuracy (liquids) or 0.7% for gases over a 30:1 turndown
- In-line sizes from 2 " to 72 " (221 Only)
- Fully field configurable
- Loop powered with 4-20ma output
|
|
initial smallest measurable value approx. 0.5 m/s
terminal measurable value: 40 m/s; 60 m/s and 80 m/s
working temperature range: -20 °C... 100 °C; 180 °C; 240 °C
maximum working pressure: 3 bar above atmospheric
explosion-proof type of protection: EEx ia IIC T6 for zones 1 and 0
probe materials: stainless steel, titanium, tantalum and HASTELLOY
necessary diameter of insertion opening: 40 mm
Drawing ZG2: extendable probe with probe tube diameter of 42 mm for greater insertion depths
Drawing ZG4: probe with probe tube diameter of 20 mm, with sliding probe guide piece
for installation in pipelines/ducts
Drawing ZG5: probe with probe tube diameter of 20 mm, with lapped flange and welded, integral flange
for making contact with the medium
Drawing ZG6: probe as drawing 5, with EEx ia IIC T6 type of protection for use in zone 0
Drawing ZG7: probe with probe tube diameter of 20mm with sliding probe guide piece for installation in pipelines/ducts;
probes with an installation length of 500 mm or 1000 mm, probe materia stainless steel for use in non-hazardous areas
|
|
Whatever your process or system requirements, there is a flowmeter to suit your needs from the Spirax Sarco range. Our
flowmeters have an unrivalled reputation for accuracy, turndown and reliability. They are versatile, being suitable for steam
as well as most liquids and gases. A comprehensive selection of flow computers and display units, all of which can be
linked to plant and building management systems, complement the range. |
|
| The RWG and RWBG Series meters are wafer-style in-line flow meters designed to offer high accuracy gas flow measurements with very low pressure drop. The meters have no moving parts and are virtually maintenance-free once installed. The RWG series is suitable for most gas types. The RWBG series is similar in construction but optimized for low-pressure "wet gas" or "BioGas" applications, typically CH4 + CO2 mixtures. All meters in these series are loop-powered devices with standard HART® communications, CE mark and optional ATEX hazardous area certification. Through the use of an internal RTD and an external pressure sensor (optional), the flow meter software will compensate for changes in pressure and temperature, to achieve an accurate mass flow measurement. |
|
| Racine Vortex offers high-accuracy vortex-shedding flow meters for a number of liquids and gases. The product line is quite unique: by incorporating ultrasonic technology, the meter's bluff body ("strut") has a considerably smaller footprint compared with other vortex-shedding flow meters. This results in very low pressure drop in the system. Meters are available in wafer (in-line, 1/2" to 4" size) or insertion styles (4" line size and higher). This vortex-shedding technology involves no moving parts, and the meters are virtually maintenance-free. Loop-powered gas flow meters offer HART communications, temperature compensation for mass flow measurement and gas flow standardization, CE-mark and optional ATEX hazardous area certification. Liquid flow meters also carry the CE mark. |
|
The RWS Series meter is a wafer-style in-line flow meter designed to offer high accuracy measurements of saturated steam flow in a variety of applications. The meter has no moving parts and is virtually maintenance-free once installed. All meters in these series are loop-powered devices with standard HART ® communications for ease of field programming and system integration.
Racine Vortex flow meters utilize the smallest strut in the industry, which allows for high levels of sensitivity; superior performance at very low flow rates; high turndown ratios; and low pressure drop.
Through the use of an internal RTD and an external pressure sensor (optional), the flow meter software will compensate for changes in pressure and temperature, to achieve an accurate mass flow measurement. |
|
Vortex Meter VTX 2
The VTX2 vortex meter is used for flow and volumetric measurements of conductive and non-conductive fluids, gases and vapours in all industrial branches. Applications include volumetric measurements for balancing (compressed air systems, heat carriers, vapours, chemical products, for example), process control and high throughput applications.
DN 15 - 300 (larger connections upon request)
PN 10 - 40
flow rates 0,4 - 20000 m³/h
accuracy gas and vapor: ± 0,9 %
accuracy liquids: ± 0,6 %
operating temperature according to design -40°C to 260°C |
|
KOFLOC FM0101/0102/0103/0105, FM31
The KOFLOC Karman Vortex Flow Meter FM0101/0102/0103/0105 SERIES is ideal for measuring pure or deionized water and chemicals as low as 0.5L/min. PPS resin used for body material and lack of moving parts assures reliability and durability. TEFLON®/PFA MODEL FM31 SERIES is also available for ultra pure water applications such as in semiconductor industry.
FEATURES
- Rohs compliance - PPS resin - Easy maintenance
- Compact & light - Acidic/Basic medium - Minimum pressure loss
- Corrosive resistance
APPLICATIONS
- FA instruments - Semiconductor manufacturing - LCD
- Housing material production - Medicine production - Chemical industry
- Biomedical applications - Environment systems - Food processing
- Agricultural/Botanical applications |
|