- Metrology - Laboratory >
- Analytical Instrumentation >
- Chromatograph accessories
Chromatograph accessories
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
For anion preconcentration and matrix elimination. The enlargement of the packing bed increases the capacity of the two preconcentration columns completely made of PEEK. The high capacity is required primarily when matrix effects might cause an overloading ...
Metrohm
In the case of the Microbore version of the Metrosep A Supp 16 - 100, lower flows are applied through the smaller inner diameter. Eluent consumption is reduced drastically as a result. The dwell time of the ions in the detector becomes longer and the ...
Metrohm
... High-capacity anion column, which is used to purify the eluent flow. Even chemicals of the highest quality level, e.g. "Ultrapur" or "puriss", can still contain minimal anion contaminations. These are reliably held back by the Metrosep A Trap 1 - 100/4.0. This ...
Metrohm
... Chromolith® columns are made of monolithic silica with a characteristic bimodal pore structure. Chromolith® Performance RP-18 endcapped HPLC columns have macropores with 2 μm diameter, giving a column efficiency exceeding 80,000 plates/meter. The mesopores ...
Merck Millipore
... For research use only. Not for use in diagnostic procedures. ChromXP columns optimize performance, ease of use, and reliability of the SCIEX M3 MicroLC, MicroLC 200 Plus and NanoLC 400 systems. ChromXP columns ensure optimum separation and long term ...
Collect full spectral data for postacquisition analysis with the Thermo Scientific™ Dionex™ UltiMate™ 3000 Rapid Separation Diode Array Detector. It supports both HPLC and UHPLC applications with eight channels of single-wavelength data acquisition, a ...
... Overview
Shim-pack Arata is a reversed-phase HPLC column series developed to deliver superior peak shape and reliable resolution for basic and polar basic analytes. It addresses common issues such as peak tailing of highly polar basic compounds, ...
Shimadzu France
... A Solid-Core Particle that Lives Up to Its Potential Unleash the power of your laboratorys instrumentation. The latest addition to our family of reversed-phase columns, CORTECS® 1.6 µm and 2.7 µm solid-core columns deliver new levels of performance. ...
Waters
Rigaku Oxford Diffraction offers the PILATUS3 R 200K as the standard detector for single crystal systems. PILATUS3 R detectors are true photon counting devices that combine the following features to make them the best commercially available detectors ...
... Overview
The vigi e-nose is an analytical instrument that simultaneously provides chemical and olfactive fingerprinting for volatile organic compounds (VOCs), sulfur compounds and other odorant molecules such as ammonia. It supports correlation ...
... Product overview
A prepacked normal-phase flash chromatography column containing 60 µm spherical silica media, designed for high-quality normal-phase purification from milligram to multi-gram scale in drug discovery and research. The column ...
... Overview
An entry‑level, plug‑and‑play prepacked flash purification cartridge designed for routine flash chromatography workflows. Available in sizes from 5 g to 300 g to suit a range of sample loads and process scales.
Compatibility
- Compatible
... Overview
Prepacked columns with your preferred media. Scale purification with confidence: Biotage columns (Flash 75 / Flash 150 M/L / Flash 400 M/L, up to FL400L ~40 kg) can be prepacked with silica, alumina, ion-exchange media, scavengers or ...
The PORTAFID® M3K portable gas detector is the perfect tool for above-ground inspections of underground gas lines. It is reliable and highly accurate, resistant to interference from moisture and only responds selectively to hydrocarbons. The PORTAFID® ...
... Delivering accurate UV-VIS and spectrum data with up to seven specific wavelengths simultaneously for analytical and preparative aplications using the 171 and 172 Diode Array Detectors (DAD). With fiber optic light paths in either fixed or remote flow ...
Developed by SRA Instruments, the Optimode is the heart of your two-dimensional chromatography system. It controls the modulation process and optimizes the collection and transfer of analytes from the first column into the second. The Optimode controls ...
Olfactory detection ports (ODPs) enable odour characteristics to be associated with particular compounds, by taking advantage of the human nose – with its extraordinary sensitivity and selectivity – to record analytes as they elute from a GC column.As ...
... MN offers different on-line column configurations designed to fit your on-line SPE analysis needs and filled with a choice of different particle sizes and modifications: Ready-to-use EC columns or ChromCart® cartridges for online-SPE Standard dimensions ...
MACHEREY-NAGEL
... Huberg Metrex A robust design and an easy to use interface ensure the new METREX is ideal for first responder technicians who handle suspected gas leaks. Other key applications include bar hole gas measurement testing, purged gas lines, enclosed space ...
RediSep Rf columns are precision-packed for high resolution and reproducibility. They feature a one-piece design with no cumbersome or expensive adapters, valves, barrels, or other accessories. Luer end fittings provide quick, easy connection to Teledyne ...
UPY-100 Rapid Pyrolysis RoHS Detector is exquisitely engineered by Skyray for rapid screening of 4 phthalate esters(DIBP, DBP, BBP, DEHP) in RoHS 2.0 Directive (EU 2015/863) .It is the only IEC62321-compliant rapid pyrolysis detector in China. The working ...
Nucleosil C18 phases are suitalbe for reversed phase chromatography and ion-pairing chromatography for the separation of nonpolar to moderately polar compounds such as fatty acids, glycerides, polycyclic aromatics, esters (phthalates), vitamins, steroids, ...
Knauer
In 1974, Tekmar developed an idea that revolutionized the way laboratories performed Volatile Organic Compound (VOC) testing. Since then, Tekmar has continued to build on the foundation of the initial Purge and Trap technique one innovative layer at a ...
Separchrom PC01 ECOM columns correspond to the highest requirements of preparative liquid chromatography. They are designed to be used in a mode of axial compression with a moving input piston. In the original design, they are equipped with identical ...
ECOM
... PRODUCT INTRODUCTION Tianjin Zwinsoft Technology Co., Ltd. has successfully launched ZWIN-FVOCs06 volatile organic compounds continuous monitoring system based on patented technology, integrating many years of R &D and application experience of environmental ...
Tianjin Zwinsoft Technology Co.,Ltd.
Asia Automated Reagent Injector allows automated aspiration and loading of multiple reagents into injection loops under inert conditions; and subsequent pressurization prior to injection. Removable racks for a range of vial sizes and pre-pressurization ...
The Reprospher is a high pressure liquid chromatograph clumn. Altmann Analytik produces reprospher in a wide range of dimensions. Packing materials can be 100 Phenyl, 200 C18-Aqua, 200 C18-DE, 300 C18, 300 C18-Aqua, 300 C18-TN, Acedosil-C, Acedosil-S, ...
Altmann Analytik Gmbh & Co. KG
... Basic chromatographic columns with indentations above the stopcock for placing a cotton plug, with beaded rim, with PTFE stopcock and retaining device, made of DURAN® tubing ...
LENZ Laborglas GmbH & Co. KG
... MS104K gas analyzer is possible to set whether to display the maximum value, minimum value, average value or not. Data recovery function; in case of mis-operation, it is possible to select partial or full recovery. It is possible to set whether to display ...
... Capillary Column SCION Instruments has a comprehensive range of Capillary GC columns. These columns are manufactured from the highest quality materials with the most detailed specifications to ensure reproducibility, low bleed and high interness for outstanding ...
... 15, 30, and 60-meter 0.53mm metal widebore capillary columns wound on a 3.5" coil 1/8" O.D. packed columns SRI can supply and install most types of column. We prefer the metal capillary columns because they are unbreakable, can be coiled to a smaller ...
SRI Instruments
... Parallel olfactory detection of GC fractions. The ODP sniff port allows the sensing of compounds by the human nose as they elute from the gas chromatograph. The effluent is split as it leaves the column so that it arrives simultaneously at the nose and ...
HERACLES Electronic Nose is based on the technology of ultra fast chromatography. It features two metal columns of different polarities in parallel and coupled to 2 Flame Ionization Detectors (FID). Therefore, 2 chromatograms are obtained simultaneously, ...
Chrom-LinX® manual chromatography columns are the ideal choice for purification applications. Specifically designed to meet the needs for the chromatography process development in biopharmaceuticals, these columns can be packed with various commonly used ...
Flame ionization detectors (FIDs) are required for a variety of applications, and there are many models on the market. With our 30 years of experience developing GC solutions, our premium eFID (enhanced flame ionization detector) is far superior, thanks ...
ASDevices
The Thermo-FID ES is a Totalhydrocarbonanalysor in a 19" rack. Burnerair and zerogas are standardised over catalyst. The sample gas conveyance takes place with injectors over the external instrument air. (Leakage control; Exhaust Emission control; Plant ...
A universal cation column, is mainly used to analyze 6 kinds of common cations (Li+, Na+, NH4+, K+, Mg2+, Ca2+). With well separability of Na+ and NH4+ and low tailing factor of Mg2+ and Ca2+, it is suitable for environmental, water quality, medical, ...
Qingdao Shenghan Chromatograph Technology Co., Ltd
... Available either with or without a Rotaflo® PTFE stopcock, Quickfit® chromatography columns offer a simple and economic solution to your chromatography needs. These simple Quickfit chromatography columns feature a General Purpose RotafloPTFE stopcock, ...
... Polyurethane Injection Machine (Type:DA-5010) Machine parameters Power: 2KW Pressure: 5~7Kg/CM2 Working radius: 150CM Injection rate: 10~50g/s Quantitative memory: 20 group Voltage: 220V Dimensions: 1300*560*1500mm Machine introduction ●Machine ...
Adjustable bed chromatographic column used for recycling, ascending or descending applications allowing for quick and easy adjustment of the PTFE plunger. The Por. C (25-50m) glass disc gives rapid flow with a minimum of mixing. Pressure tight to 3.515 ...
The 12-800 by Gow-Mac Instrument Co is a flame ionization detector (FID) designed for gas chromatography. It features its sensitivity to most organic compounds. In addition, it is insensitive to specific functions such as temperature changes, minor flow ...
The 10x300mm PYREX® column is designed for general chromatographic column separations. The top is tooled for a No. 00 rubber stopper fit. A PTFE (Polytetrafluorethylene) Product Standard stopcock with a No. 2 plug is provided for better column control. ...
The 7115 is a contamination trap designed for use with pressure equipment, such as controllers, calibrators and pressure generators. It protects against impurities, liquids (water, oil etc.) and residues released by manifolds, gauges, transmitters and ...
... Product overview
These chromatography systems are designed for separation and purification of active compounds from natural materials for applications in flavors, food and pharmaceutical fields. The systems are commonly used for silica gel column ...
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.