- Detection - Measurement >
- Electrical Measurements >
- Other electrical measurement equipment
Other electrical measurement equipment
... Setting Master and Setting Device for various gauges on request • For example snap gauges • For TD-Gauge+ and TD-Gauge+ DIGITAL: universal setting gauge for thread gauges (from M2.5x0.45 to M18x2.5) and cylinder plug gauges (from 2.0 to 18.0 mm) Special ...
Voltage: 220 V
TFGD-4001 is used for dynamic calibration of strain gages of all types, which are used for testing parts of gas turbines and turbojet engines directly on a full-scale object. It can be used for calibration of strain gages for all types of bench tests ...
... This device is used to measure strains in tunnel linings, steel struts and reinforcing bars of piles, columns, walls and the like. The transverse measuring sensor QMS is a transducer based on strain gauge depths for placement in bores for indirect ...
The FAMAC VIB IS intrinsically safe vibrodiagnostic system based on the FDAM (fast data acquisition module) and the computer designed for the signal analysis purposes enable the processing and recording of vibrations in real time, as well as providing ...
... Best suitable for simple but very precise check of path accuracy and postioning accurcy of co-ordinate measuring machines - CMMs - and machine tools. E.g. check of positioning accuracy of rotary tables of machining centres. Design / Working The precise-worked ...
Temperature: 0 °F - 104 °F
... Description The SDM-6000 is a versatile maintenance tool that automates the service of a GX-6000 portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically ...
RKI Instruments
... Magnetic probe MP laboratory probe magnets provide simple solution for detection and inspection of magnetic inclusions in bulk materials in laboratories of processing companies and universities. NdFeB magnetic system with intensity up to 900 mT (9 000 ...
Temperature: 21 °C
Pressure: 1.03 bar
PVC and Glass Calibration Cylinders/Columns for Chemical Feed system applications. A timed draw-down of the liquid in the cylinder provides an accurate measurement of the pumps actual output against system pressure.
... Used to determinate the specific surface of cement by simple calculations that consist in measuring the time required by the air to pass between two levels marked on the manometer tube. The air goes through a cementdisc compressed into a metal cell ...
LBGsrl
... Energy measuring instrument EM-71 The EM-71 is an effective panel-mounting measuring instrument (96x96 mm) and replaces all analogue measuring instruments. 3-phase current and voltage in 6 quadrants operation in class 0,2 is measured and thereby the ...
... Setting, calibration and measuring bench. - The simplest, fastest, easiest to use, most reliable, precise, solid and long lasting - Made of stabilized cast iron - Light alloy heads - Hard metal reset switches (Widia Lappato finish) - Glass support optical ...
Gas calibration and analytical system performance validation depends on knowing how to accurately dilute gas standards. Our high-end dilution system (GC blender), based on a laser-calibrated orifice, is the result of over 30 years of experience in the ...
... 1.Overview PowerPard battery simulator adopts buck-boost tactics to control the main circuit, and advanced PWM rectification technology on AC side to realize bi-directional control of DC and AC energy. It can optimize the power factor and reduce harmonic ...
EDS 30 Insulation Fault Location device is designed to detect the location of insulation fault in IT systems. The fault location device EDS 30 communicates with the Insulation Monitoring Device (IMD30) with the ModBus RTU protocol and determines which ...
... For extra tool changer safety. To be used together with tool changer TC60, TC120 and TC180. One magnetic sensor which gives +24V signal “TC Opened” when tool changer is unlocked and one magnetic sensor which gives +24V signal “TC Closed” when tool ...
Primary current: 1 A - 5,000 A
... CSN® Current Sensors are used for current measurement in control and protection systems in power transmission links (AC and DC applications). The CSN® type Current Sensors are based on high-accuracy resistive sensors (shunt) respectively iron free cores ...
Schniewindt GmbH & Co. KG
... Blue led light The blue light flashes to indicate that calibration can be performed. Blue and other constants indicate that the power supply of the sensor is normal. The blue light will flash within 5 minutes after the power is turned on, indicating ...
Primary current: 4 mA
... AC CURRENT METER Technical specifications: - power supply: 17-30Vdc / 4mA - temperature: 0-50 ° C - reading field: 0-5Aac / 0-50Aac - analogue output: 4-20mA - filter: 100ms - dimensions (LXWXH): 41x24x31mm ...
ZR-1200 mask resistance detecter conforms to YY0469-2011 technical requirements for medical surgical masks. When different flow air flows through a certain area of mask, the pressure at both ends of the mask is detected to detect the resistance of the ...
... These products are magnetic sensors using AMR elements whose resistance varies according to the strength or direction of the magnetic field. Combination with a magnet permits non-contact rotation detection or position detection. These are magnetic switches ...
... LHK15-30 Linear Magnetic Hall Sensor Special specifications such as with spring return device are available About the LHK15-30 Linear Magnetic Hall Sensor The LHK15-30 is a long-life, linear motion contactless potentiometer with stroke 30mm. Dual ...
Althen Controls
The MV 50XX series of measuring transducers is perfect for taking stationary measurements directly at the measuring point in the open field. The measuring transducer is simple and intuitive to use. It also maintains the essential functionality with maximum ...
Temperature: -20 °C - 60 °C
Pressure: 0 Pa - 2,500 Pa
Flowcal Air Multifunction Calibrator allows to perform all necessary controls to verify the calibration of some parameters, which are normally measured by sampler, like flow rate, pressure and temperature. This characteristic makes Flowcal Air unique ...
SWR200 is a precision sine wave reference providing an ultra-stable sine wave output of +7.071V at ±0.5% initial accuracy and a temperature coefficient as low as 20 ppm/°C over the full military temperature range. This extreme accuracy is made possible ...
Apex Precision Product
SP-1000 Tension Voltage Tester is our pen type high voltage detector product developed for the products we want to control voltage.
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group