- Detection - Measurement >
- Electrical Measurements >
- Other electrical measurement equipment
Other electrical measurement equipment
This nickel-plated spring contact clip is made from high-quality brass, ensuring excellent conductivity and durability. Designed for secure electrical connections, it provides stable performance with a precision tolerance of ±0.01 mm. Ideal for use in ...
... The USB-14010-SI is a USB Isolation Adapter that supports Universal Serial Bus (USB) Revisions 1.1 and 2.0 devices. With its isolation controller, it¦s backward compatible either when the downstream port is connected to a USB1.1 or USB2.0 compliant ...
... Overview
The CS-iTVP-05 is a battery-powered wireless parking sensor that detects parking-space occupancy using an anisotropic magnetoresistive element and reports status via LoRaWAN or NB‑IoT to a gateway or operator network.
Key ...
... Insulation sticks are designed for live working up to 1 kV using the "from a distance" method when operating medium- voltage indoor electrical devices. The sticks are used to carry out maintenance work using interchangeable tools installed on them. STORAGE ...
Hubix Sp. z o.o.
... Measuring range +/- 2T Small size and flat design allowing easy installation on stator wall Interchangeable sensor head The MFT-100 is based on hall-effect sensing technology and is designed for the monitoring of hydro generators and ring motors’ ...
Compact main tester insulated with transparent plastic handle and pocket tip.
SAS
... Probe pins are used in many of our products, not only in connectors, but also in test sockets, image sensor sockets, high-frequency probe pin sockets, etc. They are used for performance inspection of semiconductor devices and substrates. Please contact ...
JC CHERRY INC.
... EPT 1000 measuring transducer for PT 1000 sensors with a wide measuring range from -50°C to +700°C Description The EPT 1000 is an advanced and precise transducer designed for temperature measurement from -50 to 700°C in industrial, commercial and residential ...
Primary current: 30 A - 3,000 A
... Detecting high current at the flexible current probe and providing a porportional low-ripple standard signal appropriate for computer use Wide frequency band can be accepted Clipped around a conductor without disconnecting the conductor Rogowski coil ...
... FUNCTION Intrinsic calibration test includes COD/PP/EFL (focal length ratio), radial distortion K1-K6, and tangential distortion P1-P2. FEATURE The fixture and chart support multi-angle precision adjustment with wide compatibility; Modular ...
HyQuest Solutions’ Field Calibration Device FCD checks rain gauges in the field for accuracy. The portable lightweight device effectively enables field technicians to run functional tests and verifications of any rain gauge in the field. The use of FCD saves ...
KISTERS - HyQuest Solutions
... SMS-PWT Power Window Tester Wireless Bluetooth S-beam Load cell for Power Window and Power Roof testing Tension and compression measuring ...
Primary current: 0.15 A - 200 A
... The CS11 monitors ac current along an electrical wire. It outputs a millivolt signal that many of our dataloggers can directly measure. Benefits and Features - Ideal applications include motor or generator load conditions, efficiency studies, intermittent ...
Temperature: -40 °C - 70 °C
... The ALS-2 Ambient Light Sensor Calibrator provides a quick and simple method of verifying the performance of the ALS-2 in the field Area: Ambient Light Sensors The ALS-2 Calibrator provides a quick and simple method of verifying the performance ...
Primary current: 3 A - 30 A
... Suitable for lower power of general purpose inverter Product Features Dual operational sensor, Compact, Lower cost Wide electrical current range ( The saturation current is 3 times the primary norminal current / S05 is 1.5 times ) PCB mounting ...
This is stund that simulates the laads af wheel and wagan an a manufactured bagie body. it opplies a set larce anto twa painls of bagie bady !ram tap. it indicotes the distributian ol larces with 4 load sensars an bonom side. There is also o side larce ...
Primary current: 2 mA
Using eddy current sensors, the closing of the tool can be measured to within a few µm. The analog output signal (0 ... 10V) is proportional to the measuring distance and enables a very precise measurement. Eddy current sensors can also be used to measure ...
Primary current: 2 A
... AC Sensor was selected by OSHA electrical technical equipment committee as the only instrument of its type for use by OSHA compliance officers to identify and cite electrical hazards of 50 volts or more. Simple to use and lightweight 2 AAA 1.5v batteries ...
... ORB-One ESE Terminal Tester can test all types of ORBITAL ESE Terminals. In periodical maintenane times, crucial for testing and understanding if the terminal might be failed due to some occasional reasons like weather conditions or external interferences. - ...
... PQWT-TCM Series geophysical Water Survey Detector: the use of natural electric field source as a working principle, with resistivity contrast underground rocks & minerals or combination of rock or mineral with groundwater and aquifer, based on natural ...
... The TBLC08 50uH LISN is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard. The device is designed for testing single phase, AC-powered equipment ...
TEKBOX
... The Air sampler calibration instrument is mainly used to calibrate all microporous plankton samplers. It can quickly and accurately measure the flow of the sampler without increasing the load of the sampler, resulting in a large deviation of the flow ...
... In-Circuit Test (ICT) equipment applies electrical signals to the printed circuit board (PCB) with mounted components to check whether various components are properly connected in the circuit. •Save 50% on tray (jig) switching time •Reduce maintenance ...
... Why is an engine repeatedly defective? How can you ensure extremely high system availability? How can you prevent engine bearing damage in hard-to-reach locations? Questions that many machine manufacturers and service companies have probably asked ...
The Permeameter for Draining Pavements is designed for measuring the water percolation time through the draining pavements. The apparatus comprises a graduated transparent cylinder, a metal support, a rubber gasket and a 20 kg counterweight with handles. ...
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group