- Hydraulics - Pneumatics >
- Filter and Separator >
- Air filter
Air filters
... • suitable to be placed on top of a silo • jet-pulse cleaning by compressed air • bag or cartridge filter elements • available filter area from 2 m² to 60 m² • removal of the filter ...
MIX S.R.L.
Operating pressure: 37, 135 Pa
Filtration size: 0.3 µm
Flow: 30, 95 l/min
... The RSG P3 Plastic Filter is a HEPA filter with an absorption capacity of 99.997%. In addition it is as a parallel pleated high-efficiency particulate filter (P100/P3) for removal of all types of particulates. This ...
RSG Safety B.V.
Operating pressure: 145 psi
Filtration size: 5 µm - 40 µm
Fluid temperature: 5 °C - 60 °C
... • (Rc thread) A lineup for filtered particle sizes of 5 pm and 40 pm. The filter element condition can be inspected visually, making it easier to see when maintenance is required. ...
Koganei Corporation
... Colasit filter systems for aggressive, corrosive exhaust air and gases are setting the standard for exhaust air systems made of plastic, and are configured and implemented according to requirements. For ...
COLASIT AG, Spiez - Switzerland
... The cartridge filters allow air purification by filtration of suspended dust. Typical is the application of blasting machines, welding cutting ...
... Disposable panel filter with fiberglass, skin backed media Industrial strength 1” and 2” depths available Wide selection of standard sizes ...
Purolator
Operating pressure: 15, 25 Pa
Flow: 400 m³/h - 3,000 m³/h
Fluid temperature: 250, 300 °C
... Applications: filtering coarse dust particles, lint and soil in civil and industrial environments: hot air generators for civil and industrial facilities; ventilation of electrical engines ...
SagiCofim
Operating pressure: 10 bar
Filtration size: 5, 35, 80 µm
... needs to be changed or if the filter unit is clogged. The filter work well with fine dust and they can not corrode or rust. Changing the filter can be done by removing the bowl with the hand and clean ...
Eurovacuum B.V.
... at both the air inlet and outlet filter surfaces. Setting up final pressure drop of filter. When pressure difference exceeds the preset final pressure drop value, the control system will send out signal ...
MayAir
... Sleeve Filter JET Applied for the separation of the pulverulent particles available on the air, the Filter type JET performs an amazing filtering action. The sleeves dress cages properly ...
Operating pressure: 46 bar
Filtration size: 25 µm
... Technical description Cleaning and decontamination of refrigerant circuits in refrigerating and air conditioning installations with change over in flow direction, including heat pumps. Temporary uses: new installations ...
CARLY
Flow: 425 ft³/min - 2,720 ft³/min
... indoor air quality is required. Multi-Pleat XL8 Construction The Multi-Pleat XL8 media is produced with an optimal blend of highly specialized fibers, developed by Koch Filter Corporation specifically for use in extended ...
Koch Filter Corporation
... The use of this type of grid is optimal to obtain a mediumfine screening, depending on the used filtration spacing. The cleaning of the filter mat is guaranteed by nozzles placed in the upper part of the machine, ...
Operating pressure: 16 bar
Flow: 20 m³/h
Fluid temperature: 65 °C
... Connection Perbunan Gasket Volume nom/max: 20/40 m3/t, Weight1 kg Complete Filter housing. incl. Energy monitor & condensate drain & PE 25my filter incl. Energy monitor & condensate drain ...
ultrafilter Skandinavien Aps
... KASCO filters are manufactured with a UNIQUE Kasco designed process and represent the best of the technology available in the sector. Flexible manufacturing facilities allow for the manufacture of even limited filter ...
Kasco s.r.l.
... Activated carbon filters - Biogas contaminants adsorption - Stand-alone or array installation - Removal of hydrogen sulfide H2S / siloxanes FCA activated carbon filters are installed for contaminants removal from ...
Operating pressure: 80, 60 psi
Filtration size: 0.22 µm - 30 µm
Flow: 1.89 l/min - 15.14 l/min
... Food & Beverage Grade Pleated Fiberglass Depth Media Capsule Filters available in 5 sizes (2, 5, 10, 20 and 30 inch lengths) with many micron ratings ...
Operating pressure: 70 Pa - 120 Pa
Flow: 1,250 m³/h - 3,400 m³/h
... AND REUSABLE FILTER Applications Washable filters for air conditioners and fan coils Air filtration in residential buildings, hotels, laboratories Prefiltration ...
MGT FILTRIxARIA
Operating pressure: 600 Pa
Flow: 170 m³/h - 17,352,000 m³/h
... cast into the frame. The filter housing seal is achieved through a leak-free fluid or dry seal-system. Testing Each HEPA filter is tested and packed in accordance with American Standard IEST-RP-CC001.3 (HEPA and ...
FILT AIR
Operating pressure: 2 Pa - 16 Pa
Flow: 100 m³/h - 2,700 m³/h
Fluid temperature: 20 °C - 45 °C
... IM-ICT Series Activated Carbon Towers reduce the oil vapour content of the compressed air to low residual levels. Oil vapour is the second largest vapour phase in compressed air and, like moisture, is ...
... Maxflow Filters - G1/4 - G 1 • Made As per ISO 5782-1 standard. • High level of condensate separation. • Sturdy construction in aluminum. • Easy removal/refixing of bowl • Bowl guard for 3/8" & " offered as a standard feature. • ...
Operating pressure: 0 bar - 12 bar
Flow: 2,500 l/min
... Air from a compressor circulating through the network contains particles and solid impurities, water from the relative humidity of the suction air and burnt oil from the compressor. All these impurities accompanied by ...
SAGOLA S.A.U.
Operating pressure: 0 bar - 2 bar
Filtration size: 0 µm - 0.1 µm
Flow: 0 m³/h - 765 m³/h
... Application: Installation downstream from vacuum pumps for aerosol-free exhaust air or upstream as pump protection Task: To separate particles and particulate matter out of gas flow, remove emissions that are hazard to health and environment, ...
Contec GmbH Industrieausrüstungen
Operating pressure: 0 Pa - 1,200,000 Pa
Filtration size: 40 µm
Flow: 0 m³/s - 0.006 m³/s
... Air filters are mounted on oiltanks with the aim to filter the air. They are also mounted in suction of compressors and engines. Available with BSP threads. Replace elements are regenerated ...
Operating pressure: 25 Pa - 450 Pa
Flow: 3,400 m³/h
Fluid temperature: 80 °C
... Production of pocket filters is made under the quality management system according to ISO 9001. They correspond with anti-fire standards for the EU and the USA (DIN 53438, UL 900). They are marked with the production mark, filter ...
EWAC spol. s r.o.
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription