- Electricity - Electronics >
- Switch and Relay >
- Combined surge arrester
Combined surge arresters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Voltage: 2, 6 kV
Primary current: 26 A
... caused by lightning strikes, electrostatic discharges or power grid switching operations, and are extremely hazardous. Such surges can cause electrical systems to fail, destroy electrical and electronic equipment, or even set entire buildings ...
Siemens Low-voltage – Power distribution
type 2 surge arresterDG YPV series
Voltage: 1,200, 1,000, 600, 150 V
Primary current: 10,000, 12,500 A
... modules Combined disconnection and short-circuiting device with safe electrical isolation in the protection module (patented SCI principle) Tried and tested fault-resistant Y circuit of DEHNguard M YPV SCI ... (FM) prevents damage to ...
DEHN + SÖHNE
type 2 surge arresterSurge-Trap® STET23 series
Voltage: 120, 230 V
Primary current: 20,000 A
... STE T23 20 is the series of combined Type 2+3/Class II+III devices for discharging voltage surges while providing a very fine voltage protection level, in accordance with EN/IEC 61643. Complete with a built-in powerful ...
Mersen - Electrical Power
Voltage: 220 V
Primary current: 25,000, 50,000 A
... Lightning and surge arrester for single phase lines (F + N) 220 V. Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and surges ...
INGESCO
Voltage: 380 V
Primary current: 25,000, 100,000 A
... Lightning and surge arrester for three phase lines (3F+N) 380 V. Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and transitory surges ...
INGESCO
Voltage: 230 V
Primary current: 12,500, 25,000 A
... Lightning and surge arrester for single phase lines (F+N) 230 V. Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and surges ...
INGESCO
Voltage: 120 V - 440 V
Primary current: 25,000, 100,000 A
... systems. Can be used in TN-S systems The surge arrester meets the requirements of IEC61643-11 The unit is designed to be used between Zone O and Zone 1 (according to IEC62305-4 definition of Lightning ...
Britec Electric Co., Ltd
Voltage: 120 V - 350 V
Primary current: 50,000, 160,000 A
... class I lightning protection test conducted by national professional testing institutions. • It is the first-level lightning protection product of ac power equipment. Application: For ...
Britec Electric Co., Ltd
Voltage: 400, 690, 440, 250, 320 V
Primary current: 25,000, 30,000, 100,000 A
... all kinds of common power systems. The surge arrester meets the requirements of IEC61643-11 The unit is designed to be used between Zone O and Zone 1 (according to IEC62305-4 definition of Lightning ...
Britec Electric Co., Ltd
Voltage: 520, 300, 555, 320 V
Primary current: 30,000, 65,000, 15,000 A
Open circuit voltage: 1,800, 1,100, 13,000 V
... Tested and certified as a protector Type 1+2 according to the standard EN IEC 61643-11. Suitable for Categories II, III, IV according to ITC-BT-23. With removable modules for replacement in the event of a breakdown or fault. Compact multi-pole ...
Aplicaciones Tecnológicas, S.A.
Voltage: 230 V
Primary current: 10 A
... V-CHECK MPT mini is the range of combined transient and power frequency overvoltage protection devices (SPD+POP), compact, pre-wired, including MCB, Type 2 / Class II, 15 kA (8/20 μs) surges, 2 pole (P+N) and 4 pole (3P+N), ...
Cirprotec
Voltage: 275, 320 V
Primary current: 20,000, 40,000 A
... -1 MOV+1 GDT combined in one cartridge. -surgearresters consisting of a base part and1 MOV+GDT plug-in protection modules. -High energy MOV and GDT hybrid unit inside. -Low residual voltage and quick response. -Reliable ...
Voltage: 1,500 V
Primary current: 30,000 A
... Lightning/ Surge Protector type 1 combine type 2 at 1500VDC to protect the solar PV circuit from over-voltage or directly lightning damage. The 1500V T1+2 DC SPD BUD-S1500 is developed according to the newest PV standard ...
Voltage: 230, 400 V
Primary current: 5,000 A
... Leutron serie EP D ... is a surge protector for equipment, to be installed as close as possible to the equipment. EP D TN 275(/FM) is a two-pole SPD in a single block for a two-pole TN-Power Net Systems. EP D TNC 275(/FM) ...
Leutron GmbH
Voltage: 0 V - 1,000 V
Primary current: 3,000, 5,000 A
... Transient surge protection device for protection of final equipment (TV, PC, etc.). This fine protection minimizes the damage that these transient surges can cause to equipment. The device incorporates protection with ...
... installations. The family of arresters is designed as pass-through adapters for systems based on coaxial cables. The DGA xx TV provide protection against part of the lightning current or against surges and as a combined ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group