- Health - Safety - Environment >
- Air Treatment and Noise Management >
- Corrosion-proof fan
Corrosion-proof fans
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Air flow: 1,206 m³/h - 1,465 m³/h
Noise level: 88 dB
... vane for optimal performance • Safety screens per OSHA; plated steel • Glass-reinforced, polyester resin, spark-resistant fan blade • Reversible, locking, inlet flange for ducted and non-ducted applications • Auto thermal overload ...
COPPUS
Air flow: 7,480 m³/h - 22,801 m³/h
Diameter: 451 mm - 632 mm
Rotational speed: 930 rpm - 1,462 rpm
... Direct drive, single inlet centrifugal fan. Manufactured from galvanised steel sheet. Fan supplied with inspection door and double flange included. ExII2/-G (Non-Sparking standard ATEX motor). Backward ...
Air flow: 400 m³/h - 4,900 m³/h
... grinding dust, and vapours. Additionally, the
fans are available in
ATEX versions for explosive environments, offering safe extraction solutions where needed.
With flexible installation possibilities, the
fans ...
Geovent
Air flow: 0 m³/h - 24,000 m³/h
... LEX/MEX ATEX fanThe LEX/MEX ATEX fans are high-efficiency centrifugal fans designed for safe ventilation in ATEX zones 1 and 2/22. Featuring backward-curved, self-cleaning impellers, ...
Geovent
Air flow: 0 m³/h - 24,000 m³/h
... LEX/MEX ATEX fanThe LEX/MEX ATEX fans are high-efficiency centrifugal fans designed for safe ventilation in ATEX zones 1 and 2/22. Featuring backward-curved, self-cleaning impellers, ...
Geovent
Air flow: 100 m³/h - 450 m³/h
Diameter: 125 mm
Rotational speed: 1,450, 2,900 rpm
Produced completely by injection moulding.Polypropylene housing resistant to UV rays and adjustable to 8 positions. High-performance polypropylene impeller with forward curved blades, statically and dynamically balanced, incorporating a reinforced hub. ...
PLASTIFER
Air flow: 500 m³/h - 1,600 m³/h
Diameter: 200 mm
Rotational speed: 950, 1,450, 2,900 rpm
Produced completely by injection moulding. Polypropylene housing resistant to UV rays and adjustable to 8 positions. High-performance polypropylene impeller with forward curved blades, statically and dynamically balanced, incorporating a reinforced hub. ...
PLASTIFER
Air flow: 720 m³/h - 2,000 m³/h
Diameter: 250 mm
Rotational speed: 950, 1,450 rpm
... Extract Fan Low Pressure Produced completely by injection moulding. Polypropylene housing resistant to UV rays and adjustable to 8 positions. High-performance polypropylene impeller with forward curved blades, statically and dynamically ...
PLASTIFER
Air flow: 3,180 m³/h - 44,430 m³/h
Diameter: 470 mm - 1,340 mm
Rotational speed: 385 rpm - 1,460 rpm
... to 53". Noise levels are low and efficiency is high. The body is available in galvanized or stainless steel for maximum corrosion resistance. Ideal for use in farms, greenhouses and industrial buildings. ...
Air flow: 9,600 m³/h - 52,500 m³/h
Diameter: 638 mm - 1,385 mm
Rotational speed: 393 rpm - 942 rpm
... -driven. Noise levels are low and efficiency is high. The body is available in galvanized or stainless steel for maximum corrosion resistance. Ideal for use in farms, greenhouses and industrial buildings. ...
Air flow: 13,600 m³/h - 72,400 m³/h
Diameter: 660 mm - 1,752 mm
Noise level: 65 dB - 74 dB
... closed environments Technical features of axial air extractors MTV G: - Very high air flow - 6-blade stainless steel fans - System for easy disassembly of the engine - Venturi mouthpiece in moplen - Patented centrifugal opening ...
Air flow: 3,000 m³/h - 28,000 m³/h
Diameter: 400 mm - 1,250 mm
Rotational speed: 270 rpm - 1,440 rpm
... aerodynamic performance. The surface treatment of entire product can be plastic-painted or spray-painted, therefore, the anti- corrosion and anti-rust classes is available from C3 to C5-M. Advantage 1.Large air volume; 2.High air ...
ERG Technology
Air flow: 95 m³/min
... have forward-inclined drum impellers, which are made of galvanized sheet steel. Generally, the blowers are resistant to corrosion. ...
Air flow: 3,000 m³/h - 32,500 m³/h
Diameter: 315 mm - 1,600 mm
... blades: 3, 4, 5, 6, 7, 8, 9, 10 , 12, 16 ; 3) Specially treated high-efficiency anti- corrosion motor, insulation class: F; 4) Meets GB / T1236 and GB / T3235 fan standard requirements; 5) Product advantages: meets ...
Jiangsu Fulihua General Equipment Co., Ltd
Air flow: 8,000 m³/h
... Exhaust Fan Roof exhaust fan, is provide to control of efficient air for healty storage in flat or pitched roofs. It is used to unload humidty air from silo. It should be run together with aeration fans. ...
MORO
Air flow: 0 m³/h - 100,000 m³/h
... BIFURCATED FAN Type HCDS Smokes and hot gas exhausters - Industrial ventilation - Tertiary ventilation Bifurcated fan with axial impeller, directly driven with motor outside the airflow in a sealed chamber to resist ...
Air flow: 0 m³/h - 31,908 m³/h
Diameter: 630 mm - 1,000 mm
Rotational speed: 0 rpm - 1,100 rpm
... simulation technology, reasonably designed flow runner combined with ultra-efficient motor create the high efficiency of the fan. [ Low Noise ] The designer closely combines aerodynamics and sound source, and makes the blade angle ...
Zhongshan EBS Technology Co., Ltd.
Air flow: 1,000, 1,450 m³/h
Noise level: 76, 83 dB
... applications where forced ventilation or aspiration is required. Construction: Body in steel sheet with anti- corrosion epoxy coating. Fan in galvanised steel sheet. Two threaded holes M20x1.5. ...
CORTEM
Air flow: 6,100 m³/h - 115,950 m³/h
Rotational speed: 940 rpm - 2,910 rpm
Noise level: 48 dB - 78 dB
... Dynamic wall mounted extractor fans with motorised hatch, for smoke exhaust in case of fires, 400 °C/2h and 300 °C/2h Dynamic wall-mount extractor fans with motorised opening system for connection to extract duct. ...
SODECA
Air flow: 0.198 m³/s - 0.566 m³/s
Diameter: 250 mm
Rotational speed: 2,780 rpm
... high quality pressure die cast aluminium. Corrosion resistance The fan casing is hot dip galvanised after fabrication to BS 729, offering enhanced corrosion resistance. Weather Resistance The ...
ELTA FANS
Air flow: 250,000, 500,000 m³/h
... Installation with steel or concrete bearing pedestal Special models • Ex-protection • Galvanized • Wear protection • Corrosion protection • Pressure resistant and pressure shock resistant • Conveyor and ripper ...
Pollrich GmbH
Air flow: 3,000 m³/h - 90,000 m³/h
... impeller with large air volume, high pressure, high efficiency, etc. ※ This series fan's pressure is higher than axial flow fan, fan flow is bigger than centrifugal fan. ※ Single speed ...
Zhejiang Pengxiang Hvac Equipment Co., Ltd.
Air flow: 0 m³/s - 1.53 m³/s
Diameter: 300 mm
Rotational speed: 5,000 rpm
... Stationary pneumatic axial fan with 300 mm nominal diameter for various ventilation work. Suitable for e. g. tank aeration, cleaning work and many other applications in explosive areas. Earthing required. ...
Air flow: 2,000 m³/h - 5,200 m³/h
Rotational speed: 2,850 rpm
Noise level: 70 dB
... TopAir Systems offers high-quality outdoor centrifugal fans. The roof/side wall fans are weather resistant, built upon on a PVC structure and polypropylene impeller. The motor offers a 3 Phase 200-380V 50Hz power supply, ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group