- Electricity - Electronics >
- Switch and Relay >
- Disconnect switch
Disconnect switches
Primary current: 40 A - 125 A
VAC: 230, 400 V
... loaded electrical circuits - As a main circuit breaker - Protection of heavy loaded electrical circuits Applications: - Industrial and administrative buildings Mounting: On a DIN rail Standards: ЕN60947-3 ...
Elmark
Primary current: 25, 16 A
VAC: 400, 690 V
... temperature use:-40℃≤Ta≤55℃ Degree of protection:IP65 Rated current:16(690V AC)/25A(400V AC) Terminal:2*6mm2 Capacity of switch:AC 3 230V 25A 400V 25A 500V 20A 690V 16A Material of enclosure:Anti-static glass fibre reinforced polyester ...
VAC: 12 kV - 36 kV
... 3 - Off-Load Disconnectors : up to 36 kV (On-Load on demand) Manual or Motor Operated Various Rated Currents & Short-Circuit Currents ...
MS Resistances
Primary current: 63 A - 630 A
... QSA Isolating Switch Fuse Application Used to cabinet and drawer electrical controlling sets of equipment. Used as power switch isolating switch and emergency switch to protect circuit ...
Primary current: 160 A
VAC: 400, 690 V
... The products of this line are our offer to the needs of plant engineering of high flow rate. It includes only items made by our trading partners ETI, EFEN and EATON. Within this line are CH fuses and fuseholders, D0, NDZ, NH fuses and fuse bases and ...
OMEGA FUSIBILI
Primary current: 25 A - 30 A
... Whether for cleaning, maintenance, or repair—with switch disconnectors in types of protection Ex d, Ex tb and Ex tD, you safely disconnect machines and equipment without the need for specially trained staff. Supporting ...
Primary current: 21, 22, 23 A
VAC: 490, 230, 400 V
... EVO40 is a multipole safety switch-disconnector with independent manual rotary control, designed for on-load shutdown/breakdown and safety isolation of LV electrical circuits. Highlights •Up to 6 ...
MARECHAL ELECTRIC
Primary current: 630 A
VAC: 24, 36 kV
... Insulated medium voltage overhead switch-disconnecter with SF6 and controlled manually or remotely with up to 36 kV. Installation on an overhead network. The NOGARIS OP overhead switch-disconnecter is installed ...
Primary current: 0.1 A - 25 A
VAC: 400 V
... with integrated motor protection can be controlled in a few simple steps using level electrodes, level controllers or a float switch. The version with level relay offers the possibility of operating the level electrodes or level controller ...
... Key switch for disconnectors. Used for current and motor isolation; Complete with 6 main pole (NO) switch; Material: brass and/or stainless steel; Suitable for use in corrosive and non-corrosive environments; ...
... The HOPPECKE sun | fusebox is a convenient battery fuse switch with high safety standards as per DIN EN 50272-7. Wall mounting combined with strain relief for cables facilitate simple and safe installation. Its high flexibility ...
VDC: 750, 1,500, 3,000 V
... Segragated compartment for each Disconnector and/or Load Break Switch and for each cable incoming/outgoing. LBD DC Disconnecting Cubicles has a withdrawable execution on request. Segragated low voltage compartments ...
Primary current: 160, 250, 400, 630 A
... FUSE SWITCH-DISCONNECTORS – VERTICAL DESIGN Used for protection of electrical grid from short-circuiting and overloading. Intended for installation on collectors. Easily installed, take up little free space on the installation board ...