- Electricity - Electronics >
- Cable, Connector, Enclosure >
- IEC electrical cable
IEC electrical cables
Nominal voltage: 100 V
Temperature: -30 °C - 80 °C
... Data cable for PROFIBUS PA according to IEC 1158-2. It enables data communication and energy on the same bus. According to international standard IEC1158-2. According to standard: DIN 19243 T3 and ...
Cross-section: 16 mm² - 120 mm²
... Wiring of concentric layers. So, the difference compared to copper cables is the fact that the latter is very flexible. The Earth cable is indeed a rigid cable. Earth cables are ...
Nominal voltage: 600 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
... without requiring additional protection. This cable can withstand damp conditions including total immersion in water (AD7). 1. Conductor Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. 2. ...
Top Cable
Nominal voltage: 600, 1,000, 1,500 V
Temperature: -50 °C - 115 °C
Cross-section: 120, 185, 240 mm²
... ready-to-install flexible wire replacement solution. Round IBS Advanced connect to the terminals of an electrical device without the need for additional accessories, such as angular connectors, spreaders, ring terminal ...
Nominal voltage: 1,500, 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 35 mm²
... Photovoltaic DC Cable Product Certification TÜV Rheinland 2PfG 1169 Testing Standard Cold bending test: EN 60811-1-4 Vertical burning test: EN 60332-1-2 2) SI-62930 IEC131 Dual-core Photovoltaic Cable Product ...
Nominal voltage: 10 kV - 36 kV
Cross-section: 50 mm² - 400 mm²
... • ISO 9001, IEC, CE, RoHS, CCC, KEMA, BS, DIN and ICEA upon request • Conductor: Compact stranded copper conductor, Cl.2 as per IEC 60228 • Conductor Screen: Semi-conductor; Screen : Copper tape • Insulation: XLPE(cross-linked ...
Cross-section: 5.89 mm² - 38.7 mm²
... • ISO 9001, IEC, CE, RoHS, CCC, KEMA, BS, DIN and ICEA upon request • ALL Aluminium Alloy Conductor (AAAC) standard: ASTM B399, EN 51082, IEC 61089 • Applications range from extra high voltage (EHV) transmission lines ...
Nominal voltage: 0 V - 1,000 V
Temperature: 70 °C - 1,200 °C
Cross-section: 0.1 mm² - 2.5 mm²
... Instrumentation Signal Cables minimize noise and signal interference, delivering clean signals in harsh environments and general manufacturing operations. These cables are designed for use in communication and instrumentation. Technical ...
Cross-section: 35 mm²
... electrolytic copper cable. Stranded cable is easier to install than solid round conductor. • Dimensions : 35 mm² • Weight per meter : 320 g/m • Materials : Electrolytic copper • Stranded : 7 x ø2.5 mm • Sheath ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group