- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Round electrical cable
Round electrical cables
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Nominal voltage: 600 V
Temperature: -40 °C - 120 °C
Multicore Cable, Conductor Diameter Range .037 in [.95 mm], Outside Cable Diameter .091 – .11 in [2.3 – 2.8 mm], 600V Voltage Rating, RAYCHEM ZH-100 • TE Internal Description: RL1111-0.50-9-0 • All ...
TE CONNECTIVITY
Temperature: -40 °C - 85 °C
Length: 20 m - 500 m
A cable as an antenna: radiating cable for the industry Cranes, elevators or rail-guided vehicles such as overhead monorails: IWLAN RCoax radiating cables enable a reliable radio connection, ...
Nominal voltage: 250 V - 600 V
Temperature: -30 °C - 80 °C
For inspection robots in coolant channels or nuclear tanks, these composite cables are the best choice. It has 1 screened strand of 4 conductors 0.75mm², 2 conductors 2.5mm², 16 conductors 0.25mm² and 9 conductors 0.34mm². ...
... robotics are also applied in industrial screwdriver-cable applications where similarly high demands are made on the products; be they spiralled, round or flat. We will develop and produce screwdriver ...
Nominal voltage: 350 V
Temperature: -40 °C - 70 °C
Cross-section: 0.14 mm² - 0.34 mm²
... at 30 MHz, approx. 250 Ohm/km Minimum bending radius - flexible 7.5x Outer-Ø fixed 4x Outer-Ø Copper wire bare, extra finely stranded Wire structure: 0.14 mm²: approx. 18 x 0.1 mm 0.25 mm²: ...
HELUKABEL
... Form stable cable with tubular, aluminum outer conductor •Minibend CT & MINI141 CT - Flexible cable assemblies Minibend style with bend-to-the-end connector termination •Multiflex ...
Nominal voltage: 500, 300 V
Temperature: -40 °C - 70 °C
Cross-section: 0.22, 0.5, 1.5, 0.75, 1 mm²
In this chapter you will find multi-pair compensating and extension cables with PVC insulation for a temperature range up to 70°C.
SAB BROECKSKES GMBH & Co. KG
Temperature: 250 °C
Cross-section: 1, 0.22, 0.5 mm²
The PFA insulated extension cables for thermocouples are used for temperatures up to 250°C. They are available with galvanized as well as with a stainless steel wire armouring.
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 1,500, 500, 350 V
Temperature: -30 °C - 70 °C
Cross-section: 0.14 mm² - 1.5 mm²
PVC data cable LiYY with reference to DIN 47100 Marking for LiYY 03053225: SAB BRÖCKSKES · D-VIERSEN · LIYY 32x0,25mm²CE LiYY Cable - The PVC/PVC data cable is a flexible data cable ...
SAB BROECKSKES GMBH & Co. KG
Cross-section: 0.5 mm² - 2,500 mm²
Length: 25 m - 1,000 m
Hard and soft copper cables for electrical applications. At Bronmetal we supply round copper wires for electrical applications. We supply copper conductor cable ...
Nominal voltage: 600 V
Temperature: 80 °C
Cross-section: 0.14 mm² - 95 mm²
Nominal voltage: 300 V
Temperature: 90 °C
Cross-section: 0.08 mm² - 240 mm²
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 50 mm²
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in ...
CAE GROUPE
Nominal voltage: 300 V
Temperature: -30 °C - 70 °C
Length: 500 m
CAE GROUPE
Nominal voltage: 1,000 V
Temperature: -25 °C - 60 °C
The RVFV cables are the power cables for use on industrial sites and the upright columns of buildings. • conform to RoHS • resistant to aliphatic hydrocarbons conductor material bare copper strand
CAE GROUPE
Nominal voltage: 300, 600, 30 V
Temperature: 80, 105 °C
Cross-section: 0.15 mm² - 5.5 mm²
Electronic equipment robot cable > Application - Appropriate for cable veyor wiring for high-speed moving. - Cable Bear test 50 million times or more, (or more ability 100 million ...
TAIYO Cabletec Corporation (Taiyo cable)
Nominal voltage: 300 V
Temperature: 30 °C - 105 °C
Cross-section: 0.2 mm² - 2.08 mm²
... times or more.) - Appropriate for cable bare wiring for high-speed moving. (Cable Bear test 20 million times or more.) - CL3X tha is the listing standard is acquired and it correspomds to NFPA70, 79. - ...
TAIYO Cabletec Corporation (Taiyo cable)
Nominal voltage: 300 V
Temperature: 30 °C - 105 °C
Cross-section: 0.2 mm² - 1.3 mm²
... times or more.) - Appropriate for cable bare wiring for high-speed moving. (Cable Bear test 50 million times or more.) - CMX tha is the listing standard is acquired and it corresponds to NFPA70, 79. - ...
TAIYO Cabletec Corporation (Taiyo cable)
Nominal voltage: 2, 3 kV
Temperature: -50 °C - 180 °C
Cross-section: 10 mm² - 300 mm²
... mm² out of single insulated silicone extruded cables 1,8/3 kV with cable shoe-shaped contact areas and additional insulation crimp Technical data Electrical conductor: • Round ...
Nominal voltage: 2, 3 kV
Temperature: -50 °C - 180 °C
Cross-section: 70 mm² - 300 mm²
... flexible power connections consisting out of extruded silicone cable with solderless crimped, cable lug shaped contact areas Conductor •Highly flexible round stranded ...
Temperature: -40 °C - 85 °C
... • Any application (e.g WLL, GPS, LMR, WLAN, WISP, WiMax, SCADA, mobile antennas) requiring an easily routed, low loss RF cable
Times Microwave Systems
Nominal voltage: 15 V
Temperature: -65 °C - 200 °C
... shielded twisted pair cables in a low-profile design that’s 30% smaller, reducing their weight by as much as 50% compared to standard oval cables. If you compare our design side by side with alternative ...
W. L. Gore & Associates, Inc.
Temperature: -10 °C - 105 °C
ANSI PVC Insulated Thermocouple Cable with Plug and Socket Cable Description PVC insulated flat pair construction Conductors laid flat PVC insulated with overall PVC sheath All round ...
... copper shield Weathering cables are resistant to harsh environmental conditions The flat cable requires less space than the round cable The radius of curvature is ...
Derulcable (Shanghai) Co., Ltd
... copper shield Weathering cables are resistant to harsh environmental conditions The flat cable requires less space than the round cable The radius of curvature is ...
Derulcable (Shanghai) Co., Ltd
... copper shield Weathering cables are resistant to harsh environmental conditions The flat cable requires less space than the round cable The radius of curvature is ...
Derulcable (Shanghai) Co., Ltd
Temperature: -40 °C - 80 °C
... Applicable products: circular connector No. 0, No. 1 Industry application: for electronic equipment and external connection PU9-core mixed cable Material Outer covering: PU Conductor ...
Cross-section: 0.75 mm² - 500 mm²
The copper cable is the essential equipment for any installation of electrical equipment. The use of wires with diameters of 0.10mm and 0.25 makes it a flexible cable. The properties ...
Cross-section: 10 mm² - 240 mm²
... . Round flexible cables are made with wire diameters of 0.07 and 0.10 mm, which can form sections up to 500 mm². These flexible round copper cables ...
Nominal voltage: 300 V
Super-Flex Round Traveling Cable Draka offers Super-Flex®, the industry’s only traveling cable with a lifetime warranty. Super-Flex has been time-tested to be the most reliable traveling ...
Temperature: -40 °C - 80 °C
... 1Gbps 1000m @ 10Mbps Podl power supply function Small cable outer diameter, flexible and light Conductor: solid bare copper conductor Insulation: foamed PE Shielding: wire to aluminum ...
Zhaolong Interconnect
Nominal voltage: 300 V - 750 V
Temperature: 60, 90, 70 °C
Cross-section: 0.75 mm² - 4 mm²
... It entails cross-border recognition of the approvals for our cable products in accordance with European / international standards. Multi-core cables (optional shielded) in flat and round ...
Nominal voltage: 15 kV
Temperature: 20 °C - 90 °C
Cross-section: 35 mm² - 300 mm²
The XLPE 15V aluminum conductor insulated cable features a compact round conductor typically made of aluminum strands, blocked or not, and comes with a cross-linked polyethylene (XLPE) cover in black ...
Henan Tong-Da Cable Company
Nominal voltage: 1,000 V
Temperature: -25 °C - 260 °C
... It entails cross-border recognition of the approvals for our cable products in accordance with European / international standards. Multi-core cables (optional shielded) in flat and round ...
Nominal voltage: 200, 250, 320 kV
Temperature: -30 °C - 60 °C
... experienced and reliable manufacturer and solution provider of submarine power cables. It forms about 4,000 kilometers of medium voltage (hereafter called MV) power cables annual output and becomes a ...
ZTT
Nominal voltage: 54 kV - 500 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
XDRCU–ALT Single–core Cable for 500/290 (550) kV with Copper wire screen and Aluminium laminated sheath Construction * Copper conductor, round stranded or segmented, optionally ...
Brugg Kabel AG
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining