Sensor amplifiers

17 companies | 27 products
{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.defLight}}
{{#if company.requestButtonsVisibility.requestButtonQuestion == "ACTIVE"}}
{{elseif company.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.defLight}}
{{#if company.requestButtonsVisibility.requestButtonQuestion == "ACTIVE"}}
{{elseif company.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement5.length}}
fiber optic amplifier / signal / digital / high-power
fiber optic amplifier
FS-N series

Voltage: 12 V - 24 V

Keyence provides FS-Neo digital fiber optic sensor that automatically detects reduced light intensity due to misalignment or debris build-up and automatically re-calibrates to the original display. It contains a multitude ...

sensor amplifier
sensor amplifier
KK, KU series

Voltage: 16 V - 55 V
Current: 50, 15 mA

Level Sensors Amplifier Series KK-KU For sensors KGFT up to +230 °C IP 67 Protection LED display

signal amplifier / for sensors
signal amplifier
IKM series

Voltage: 24 V
Current: 0 mA - 18 mA

Amplifier Series IKM For the connection of separate sensors for extreme temperatures LED display

signal amplifier / for sensors
signal amplifier
MVR

Voltage: 0 V - 10 V
Current: 0 mA - 20 mA

Series MVR amplifiers are available with 30 AC/DC (optional 250 AC/DC) supply and output signals 0..2V, 0..5V, 0..10 V (optional ±5V, ±10V), 4..20 mA and 0..20 mA. For direct connection of linear and rotary potentiometer ...

signal amplifier / electronic / for sensors / DIN rail
signal amplifier
AM-OP series

Voltage: 24 V - 260 V
Current: 300 mA

OPTOCOUPLED STATIC OUTPUTS • 1 or 2 channels • General Features: These units allow to amplifiy signals from NAMUR sensors or contacts. Each output is electrically insulated from each other, from power supply and ...

See the other products
BDC ELECTRONIC
signal amplifier / switching / electronic / with relay output
signal amplifier
AM-RL series

Voltage: 24 V - 260 V
Current: 5 A

... to amplifiy signals from NAMUR sensors or contacts. The relay outputs have changeover N.O. + N.C. contacts electrically insulated from each other, from power supply and from all the inputs. When used for NAMUR sensors, ...

See the other products
BDC ELECTRONIC
signal amplifier / electronic / for sensors / DIN rail
signal amplifier
AM-TOP series

Voltage: 24 V - 260 V
Current: 300 mA

• OPTOCOUPLED STATIC OUTPUT • 1 Timed channel General Features: These units allow to amplify signals from NAMUR sensors or contacts. The delay time and hold time respect the input signal are adjustable through potentiometers ...

See the other products
BDC ELECTRONIC
signal amplifier / electronic / for sensors / DIN rail
signal amplifier
ALNC

Voltage: 12 V
Current: 50 mA

... signal of the same in a changeover contact 5A at 240V of a relay in this device. The ALNC model amplifies the signal of sensors with NPN / PNP / NAMUR output.

signal amplifier / electronic / for sensors / DIN rail
signal amplifier
ALN2

Voltage: 12 V
Current: 25 mA

... inductive sensors with stabilized and leveled voltage, transforming their output signal into an exchange contact from 5A to 240V of the two corresponding relays present in the equipment. The ALN2 model amplifies the ...

signal amplifier / conditioning / electronic / adjustable
signal amplifier
ELECTRA – VNR 21.22

Voltage: 110, 220, 24, 230 V
Current: 6 A

... a signal conditioning amplifier that is integrated with an IP40 protection class. It is built with an LED alarm indication. An adjustable sensitivity rate that may either come in 10-250 uS or 1-10 uS is integrated. The ...

signal amplifier / electronic / for sensors / DIN rail
signal amplifier
ELECTRA – VNR 23

Voltage: 230, 24 V
Current: 5 A

The VNR.2300 signal amplifier has been designed as a low cost electronic support into the liquid level conductive control system. It is used for the signal output from conductive probe. It is equipped with an alarm LED ...

signal amplifier / electronic / adjustable / for sensors
signal amplifier
ELECTRA – VNR 23M

Voltage: 230, 24 V
Current: 5 A

Probe signal amplifier – Signal input from conductive probe – Adjustable sensitivity and delay – 2 measuring channels – Microprocessor technology – DIN rail mounting

signal amplifier / switching / for sensors / single-channel
signal amplifier
D1030

Voltage: 24 V
Current: 1.2 mA - 2.1 mA
Frequency: 10 Hz

... zone 0 (Ex zone 20), Division 1, installation in Ex zone 2, Division 2 24 VDC Input potential-free contact or Ex inductive sensor according to NAMUR D1030S: Input 1-channel, Relais output 2 change-over D1030D: Input ...

charge amplifier / for sensors
charge amplifier
2680M

... charge amplifiers, which are manufactured by Meggitt, are designed for use with piezoelectric transducers and are suitable for airborne applications. These amplifiers have an output voltage proportional ...

See the other products
Meggitt Sensing Systems - Measurement Group
power amplifier / measuring / benchtop / compact
power amplifier
SR-2200

... current sensor amplifier suitable for field measurement. The SR-2200 amplifier accepts constant current line drive sensors and connects the signal to analyzers and recorders ...

voltage amplifier / measuring / electronic / for sensors
voltage amplifier
DMSVE series

Voltage: 5, 10 V
Current: 0 mA - 24 mA

... for recognition of the sensor data using a GMV2 (Measurement range, Output voltage, Serial number, calibration data) Built-in version (cicuit board only) DMSV1 For supplying strain gauge bridges and signal gain The ...

voltage amplifier / measuring / acquisition / electronic
voltage amplifier
MA-U

Voltage: 10 V
Frequency: 50 kHz

... with potentiometers - 4mA power source or ±12V DC or +5V for sensor supply - DC or AC decoupled - reusable for other measuring tasks CONDITIONED TO VOLTAGE. The measuring amplifier MA-U adjusts ...

See the other products
BMC Messsysteme GmbH
charge amplifier / electronic / for sensors
charge amplifier
4711A1

The 4711A1 series from Dytran is an in-line charge amplifier that is especially designed with stainless steel to ensure highly durable performance when in use. It features a 10-32 jack input connector and a BNC plug ...

switching amplifier / for detection / with relay output / single-channel
switching amplifier
ISG-A1 series

Voltage: 24, 115, 230 V

Single-channel opto sensor Tailored to operate in car washes Range up to 25 m Automatic setting of the transmitting power for mounting distance and alignment purposes High safety against ambient light, disturbing ...

power amplifying integrated circuit / electronic / for sensors
power amplifying integrated circuit

The Manner sensor signal amplifier captures the measuring signal from the rotating sensors. In addition to DMS sensors, other sensors such as thermocouple ...

charge amplifier / instrumentation / electronic / for sensors
charge amplifier
1-328 series

Current: 20 mA

Features: Low Impedance Output Extremely Low Noise User Selectable Gain Wide Frequency Response Acceleration and Velocity Outputs Applications: Test Cell Instrumentation Automotive R&D Aerospace Flight ...

signal amplifier / conditioning / switching / for sensors
signal amplifier
KFA, KFD series

Voltage: 20 V - 253 V
Current: 7 mA - 40 mA

1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Relay contact output, Minimum/maximum control, Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay

switching amplifier / signal / with relay output / for sensors
switching amplifier
DN0210, DN0220

Voltage: 110 V - 240 V
Current: 4 A
Power: 11 W

... conventional sensors are designed for small load currents. If the user wants to switch higher currents or even alternating currents, he must use a switching amplifier. It uses the sensor ...