- Electricity - Electronics >
- Switch and Relay >
- Surge arrester
Surge arresters
Voltage: 500 V - 1,000 V
Primary current: 20,000 A - 40,000 A
... The Surge Protection Devices (SPD) protect the photovoltaic system against excess voltage induced by atmospheric discharge (lightening) For the protection of the field side in photovoltaic installations, under direct current upstream ...
Cabur
... IS-75BB/18 Baseband Coaxial Protector 75 ohm coaxial protector configured with BNC female connectors for dc to 30 MHz signals Specifications for PolyPhaser IS-75BB/18 Mount Type Flange Frequency Range dc to 30 MHz Protected Side Connector BNC Female ...
PolyPhaser | Transtector
Voltage: 18 kV
... indicated when order.) 3.The frequency in AC system is 50Hz or 60Hz. 4.Power frequency voltage which has been bearing on arrester for a long time do not exceed continuous operating voltage. 5.Max. wind speed do not exceed 35m/s. 6.Apply ...
Voltage: 400 V
Primary current: 25,000 A
... • Tested and certified as a protector Type 1 and 2 according to the standard EN IEC 61643-11. • Suitable for Categories I, II, III, IV according to ITC-BT-23. • Double connection in order to facilitate wiring (limited to 63 A). • Compact multi-pole ...
Aplicaciones Tecnológicas, S.A.
Primary current: 25,000 A
... as electrical equipment the SURGYS G140-F surge arrester is specially designed. It is useful against overvoltages due to industrial operation as well as over voltages due to lightning. This kind of surge ...
SOCOMEC
... TheSSLP-VB Signal surge protector is designed according℃relevantrailway standards.lt is a type Of signal surge protector.lts pefformance complies withthe CRCC testing standard Of the Ministry Of RaiIways.lt ...
Shenzhen Keanda Electronic Technology Corporation
Voltage: 280 V
Primary current: 20,000 A
... ETITEC surge arresters protect electrical installations and devices against overvoltage effects which may occur in switching overvoltages and atmospheric discharges. The ZnO non-linear varistor is the main part of the ...
ETI
Voltage: 320, 300, 600, 1,100, 1,500 V
Primary current: 20,000, 5,000, 15,000 A
... Surge protection device type 2 with plug-in cartridge, rated discharge current In (8/20μs) 20kA per pole, 1P+N •Type of product: SPD •Type of system: 230/400VAC •Type / Class: 2 •Number of poles: 1P+N •In [kA]: 20 •Type of mounting: ...
LOVATO ELECTRIC
Voltage: 7, 16, 32, 55 V
Primary current: 700 mA
... Introducing the MTL SD Modular (SDM) range of data & signal surge protection providing the ultimate surge protection solution for process automation, instrumentation and communications networks. The MTL SD Modular ...
MTL INSTRUMENT
power supply surge protectorSM20(30)M230L205 series
Voltage: 230, 385 V
Primary current: 20,000, 30,000, 40,000, 60,000 A
... Surge protective device module (SPD-M) is an onboard lightning protection module that integrates functions, such as thermal protection, overvoltage protection, and remote signaling, and others. A single ...
Xiamen SET electronics Co.,Ltd
Voltage: 48, 5 V
Primary current: 850 mA
... two kinds of surge protection solutions for network data cable surges which can prevent your systems and equipment from surge damage caused by electrostatic discharge or lightning strike. The CableFree ...
... manufactures millions of surge protector devices (SPDs) every year. Our teams bring surge protector devices (SPDs) with our unique client-focused service & quality to the closest possible ...
LSP
Voltage: 9 kV - 48 kV
Primary current: 5,000, 10,000 A
... Distribution type surge arrester is designed to serve in distribution system and provide over-voltage protection. The varistor used in the arrester is subjected to a series of physical and electrical ...
Pomanique Electric
... Dimensions (mm) 78W x 55H x 26D Weight 130g Frequency Range DC to 1000MHZ Impedance 50ohms Connectors MJ/MP VSWR Less than 1.2:1 Inerstion Loss Less 0.3dB Max Power Rating 400W (PEP) ...
... This multi surge arrester offers a flexible light duty surge protection solution using N connectors allowing it to be mounted in line between antennas and feeder cables or coaxial cables and radio / router ...
Voltage: 0 V - 230 V
... The Isolation Transformer and Surge Protector regulates voltage fluctuations of up to 200VA on the electrical line, ensuring the safety of devices connected to the circuit. Equipped with a fuse, surge ...
Voltage: 120, 240, 277, 480, 600 V
Primary current: 20,000 A
... lightning surges and other overvoltage events. Only Raycap’s industrial surge protection technology, Strikesorb can provide uninterrupted protection from damaging lightning strikes and surge currents. ...
Raycap
Voltage: 3 kV - 36 kV
... Products are strictly in accordance with GB, IEC, IEEE and other standards Through Kema, CEPRI, XIHARI and other test reports It has excellent nonlinear volt ampere characteristics. Simple structure, no gap, small size, light weight. Fast ...
jinniu electric
Voltage: 230 V
Primary current: 10 A
... frequency overvoltage protection devices (SPD+POP), compact, pre-wired, including MCB, Type 2 / Class II, 15 kA (8/20 μs) surges, 2 pole (P+N) and 4 pole (3P+N), for 230 V with POP test button. Features • With V-CHECK MPT mini ...
Cirprotec
type 2 surge arresterFV20C/3-1000PVS
Voltage: 1,000, 1,200 V
Primary current: 20,000, 40,000 A
... 1. Description Fatech Type 2 DC surge arrester are are TUV approved, these DC surge protector 1000V SPDs are tested according to IEC61643-31 and EN50539. 2. Characteristics 1)DC surge ...
FATECH ELECTRONIC (FOSHAN) CO., LTD
Primary current: 100,000 A
... Buildings with a very high level of need for protection, known as Lightning Protecion Level 1 – LPL I (Imp=100 kA) Hospitals, banks, transmission points for GSM/BTS, water stations, power plants, aerodrome control towers, explosion prone buildings Bigger ...
Voltage: 220 V
Primary current: 1,000 A
... •Mono-phased system •Operating Voltage V(in) 220 V •Service Frequency 50/60 Hz •Activation 275 V •IEC Category Class I+II+III •Nominal Voltage UN 230 V AC(230/400 V AC - 275/420 V AC), 420 V AC(L-L) •Arrestor Nominal Voltage UC (L-N) 275 V AC, UC ...
Orbital Lightning Protection Technologies
... / Class 3 / D Class sudden overvoltage protection surge arresters are the most sensitive surge arresters and their areas of use are quite diverse. Accordingly, these surge ...
Liva Group
Voltage: 0 V - 335 V
Primary current: 20,000 A
... Monobloc SPDs 12.5 kA (ref : 23111) Max. voltage Uc : 335 V AC Max. discharge current Iimp : 12,5 kA Nominal discharge current In : 20 kA Level of Up protection under In : 1,3 kV ...
FRANCE PARATONNERRES
Voltage: 600, 1,000 V
Primary current: 20,000 A
... recommend TOP DC surge arrester ZJBENY offers the DC SPDs to top inverter brands worldwide. Supply reliable protection to the solar PV systems. 1000V Type 2 DC SPD for solar PV application BUD-40/3 is a type ...
Zhejiang Benyi Electrical Co.,ltd.
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group