PFA1 die-cast aluminium trap for underfloor extraction of gases, suitable for small and medium engine size cars. It can only be installed when the construction of the new repair shop has not yet seen the completion of masonry work and flooring in the working area. This type of system is recommended in the following cases:
Lay-out already defined and not subject to relocation, including future rearrangements;
No more than 5 extraction points on each line;
Partial cotemporaneity rate (no more than 3 out of 5);
Extraction lines no more than 40/50 m in length, including fumes expulsion duct;
Extraction points can be installed in areas that are protected from constant movement of vehicles.
Shall the TGA hose be retracted into the floor trap, it is recommended to use a quick connector between the hose and the nozzle to avoid damages. In this way the TGA hose can be completely retracted inside the trap. The TGE hose is not suitable for retraction in the trap and is recommended for external use.