OverviewDesigned to preserve sample integrity during critical bioprocessing operations. The 2D-SS sterile sampling system reduces the risk of cross-contamination and supports aseptic sampling workflows to facilitate quality control and regulatory compliance.
Applications- In-process sampling during drug and biotherapeutic manufacturing
- Sterile sampling for cell culture, fermentation and research laboratories
- Sample collection for quality control and analytical testing
Certifications- Class VI Plastics as per USP <88>
- Cytotoxicity as per USP <87>
- USP <85> Bacterial Endotoxins
- USP <661.1> Extractable metals
- SP <788> Sub visible particulate matter
- USP <71> & ISO <11737-1> Sterility assurance
Features / Benefits- Controls contamination risks during sampling
- Provides consistent and reproducible samples
- Designed for regulatory compliance and safe handling
- Customizable to meet process-specific requirements
Characteristics- Minimizes false positives and reduces cleaning cycles compared with traditional sampling methods
- Available in multiple configurations to match process requirements
Components (table)1 | Bag | 9101 Infuflex Film
2 | Tube | TPE and Silicone
3 | Needless sampling port | Body - Polycarbonate; Septum - Silicone
4 | Female Luer Lock | Polypropylene
5 | Male Luer Plug | Polypropylene
6 | Sampling needle | Needle - SS 316L; Body - Polypropylene; Septum - Silicone
Standard Sizes Available (table)# | CATALOGUE NO. | Description
1 | 2D-SS-050M-01 | Sterile sampling system with 1 x 50ml bag
2 | 2D-SS-100M-01 | Sterile sampling system with 1 x 100ml bag
3 | 2D-SS-250M-01 | Sterile sampling system with 1 x 250ml bag
4 | 2D-SS-500M-01 | Sterile sampling system with 1 x 500ml bag
5 | 2D-SS-001L-01 | Sterile sampling system with 1 x 1L bag
Technical specifications- Bag material: 9101 Infuflex Film
- Tubing materials: TPE and Silicone
- Needless sampling port: Body - Polycarbonate; Septum - Silicone
- Female Luer Lock: Polypropylene
- Male Luer Plug: Polypropylene
- Sampling needle: Needle - SS 316L; Body - Polypropylene; Septum - Silicone
- Sterility and biocompatibility standards: USP <88>, USP <87>, USP <85>, USP <661.1>, SP <788>, USP <71> and ISO <11737-1>
- Benefits: minimizes false positives, reduces cleaning requirements, contamination control, accurate and consistent results
- Customization: available to meet specific process requirements
- Available catalogue variants: 2D-SS-050M-01, 2D-SS-100M-01, 2D-SS-250M-01, 2D-SS-500M-01, 2D-SS-001L-01