Characteristics

Type
climatic
Controlled parameter
temperature, humidity
Test type
for environmental simulation
Application domain
laboratory
Configuration
compact
Light source
LED
Number of doors
1-door
Options and accessories
with window, with temperature and climatic control, touchscreen-controlled
Other characteristics
stainless steel
Capacity

228 l
(60.23 gal)

Temperature

Min.: -50 °C
(-58 °F)

Max.: 180 °C
(356 °F)

Width

1,115 mm
(43.9 in)

Power

6,800 W

Interior length

735 mm
(28.94 in)

Interior height

700 mm
(27.56 in)

Interior depth

443 mm
(17.44 in)

External height

1,713 mm
(67.44 in)

External depth

925 mm
(36.42 in)

Description

Product description
The dynamic climate chambers of the MKF CO₂ series are designed for combined temperature and humidity tests under dynamic conditions. High change rates and precise humidity control enable reproducible, standards-compliant test sequences. The standard feature set covers common laboratory and production requirements. The MKF CO₂ series uses natural CO₂ (R744) as refrigerant and provides a solution for combined climate testing with controlled condensation protection.

Benefits
  • High dynamic performance for controlled thermal cycling
  • Compact 228 L interior for sample-focused testing
  • Simple integration and intuitive touchscreen control for laboratory use
  • Data integrity via internal logger and open-format USB export

Important characteristics
  • Temperature range: -50 °C to +180 °C
  • Humidity range: 10 % to 98 % RH
  • Humidity regulation with capacitive sensor and steam humidification
  • APT.line™ preheating chamber technology
  • Cooling with natural CO₂ (R744)
  • Intuitive touchscreen controller with time-segment and real-time programming
  • Ergonomically adjustable operating terminal and illuminated signal triangle
  • Stainless-steel inner chamber and heated viewing window with LED interior lighting
  • Programmable condensation protection and Class 2 adjustable temperature safety device (DIN 12880)
  • Data interfaces: Ethernet, USB; internal data logger
  • Integrated 20 L water-storage tank and door heating to prevent condensation

Technical specifications (selected tables represented as lines)
Data
Article Number: 9020-0514 / 9020-0516
Designation: MKF240CO2-400V / MKF240CO2-480V
Option model: Standard

Performance Data Temperature
Article Number: 9020-0514 / 9020-0516
Temperature range: -50...180 °C*
Temperature uniformity dependent on set value: 0.1...1.2 ± K
Temperature fluctuation dependent on set value: 0.1...0.4 ± K
Average heating-up rate (IEC 60068-3-5 between -40°C and 180°C): 5.5 K/min
Average cooling down time (IEC 60068-3-5 between 180°C and -40°C): 5.7 K/min
Cooling down time from 180°C to -40°C: 60 min

Performance Data Climate
Article Number: 9020-0514 / 9020-0516
Temperature range with humidity: 10...95 °C
Humidity range: 10...98 % RH
Temperature fluctuation with humidity dependent on set value: 0.1...1 ± K
Humidity fluctuation with humidity dependent on set value: ≤2 ± % r.H.
Max. heat compensation at 25°C and 90% RH: 900 W

Electrical data
Article Number: 9020-0514 / 9020-0516
Rated Voltage: 400 V (9020-0514) / 480 V (9020-0516)
Power frequency: 50 Hz (400 V) / 60 Hz (480 V)
Nominal power: 6.8 kW
Unit fuse: 16.0 A
Phase (Nominal voltage): 3~/N/PE

Dimensions and weights
Article Number: 9020-0514 / 9020-0516
Interior volume: 228 L
Net weight of the unit (empty): 327 kg (9020-0514) / 335 kg (9020-0516)
Load per rack: 30 kg
Permitted load: 70 kg
Wall clearance back: 300 mm
Wall clearance sidewise: 200 mm

Housing dimensions (net)
Article Number: 9020-0514 / 9020-0516
Width net: 1,115 mm
Height net: 1,713 mm
Depth net: 925 mm

Internal Dimensions
Article Number: 9020-0514 / 9020-0516
Interior width: 735 mm
Interior height: 700 mm
Interior depth: 443 mm
Unit doors: 1

Environment-specific data
Article Number: 9020-0514 / 9020-0516
Sound-pressure level: 60 dB(A)
Energy consumption at 25°C and 60% RH: 1,400 Wh/h

Fixtures
Article Number: 9020-0514 / 9020-0516
Number of shelves (std./max.): 1/6

Options, accessories & services (selection)
Lockable door handle (Door lock) - 8012-2673
Analog output 4-20 mA for temp and humidity - 8012-2674
Access ports with silicone plug (various positions/sizes) e.g. 8012-2690, 8012-2691, 8012-2692
Calibration certificates and measurement services (various configurations) e.g. 8012-2696 and DL30 series
APT-COM™ software editions (networking / GLP options) e.g. 9053-0040, 9053-0042
Maintenance and commissioning services (various DL codes)

Note
All data above are taken from the product's specification content shown on the product page. The description lists standard features and the measurable technical values provided by the manufacturer.