Telecommunications surge protection unit DLA2-06D2
for data and telecommunication lines2-pairthermoplastic

Telecommunications surge protection unit - DLA2-06D2 - CITEL - for data and telecommunication lines / 2-pair / thermoplastic
Telecommunications surge protection unit - DLA2-06D2 - CITEL - for data and telecommunication lines / 2-pair / thermoplastic
Add to favorites
Compare this product

Characteristics

Applications
telecommunications, for data and telecommunication lines
Other characteristics
2-pair, thermoplastic, gas discharge tube, RS-485, DIN rail, plug-in
Voltage

Min.: 6 V

Max.: 170 V

Primary current

Min.: 0 A

Max.: 0.6 A

Description

Description
The DLA2 series protects telecommunication, automation and data systems against lightning-induced surges. Designed for 35 mm DIN-rail mounting, the device provides plug-in protection modules for easy maintenance and supports voltages from 6 V up to 170 V with transmission rates up to 10 Mbit/s. Protection combines high-performance gas discharge tubes (GDT) and fast-switching TVS diodes for high discharge capacity and rapid response. Shield connection is additionally earthed via a GDT and the earthing is made through the top-hat rail. When the plug-in module is removed, the transmission signal is retained unless a specific disconnect version is used.

Key features
  • DIN-rail plug-in surge protector
  • 2-pair configuration with plug-in module
  • Nominal line voltage (Un): 6 V
  • Shield conductor protection
  • No line interruption in standard version
  • IEC 61643-21 / EN 61643-21 compliant

Electrical Properties
Network compatibility: RS422, RS485
Nominal line voltage (Un): 6 V
Max. DC operating voltage (Uc): 8 Vdc
Cut-off frequency (-3 dB, 100 Ω system) fmax: > 115 MHz
Cut-off frequency (-1 dB, 100 Ω system) fmax: > 50 MHz
Max. load current @25°C (IL): 600 mA
Max. discharge current Imax (8/20 µs per pole): 20 kA
Nominal discharge current (In) C2: 10 kA
Protection level Up (C3 10/1000 µs), 300 applications@10 A, Y-Y (Line/Line): 30 V
Protection level Up (C3 10/1000 µs), 300 applications@10 A, Y-C (Line/Earth): 650 V
Impulse current Iimp (D1 10/350 µs), 2 applications, X-C (Line/Earth): 5 kA
Line resistance (±10%): 2 Ω

Mechanical Properties
Network type: Data communication / Telecom
Technology: GDT + TVS diode
SPD configuration: 2 pairs, plug-in module
Network connection: Screw terminals; cross section 0.5–2.5 mm²
Format: Plug-in DIN enclosure
Mounting: 35 mm symmetrical rail (EN 60715)
Housing material: Thermoplastic UL94 V-0
Operating / storage temperature: -40 to +85 °C
Protection rating: IP20
Failsafe mode: Short-circuit
Disconnection indicator: Transmission interrupt (default mode 2) — optional versions available
Spare module(s): DLA2M-06D2
Dimensions: See diagram
Weight: 0.089 kg

Standards
IEC 61643-21 / EN 61643-21

Characteristics / Technical specifications
  • Model: DLA2-06D2
  • Manufacturer: CITEL
  • Network compatibility: RS422, RS485
  • Nominal line voltage (Un): 6 V
  • Max. DC operating voltage (Uc): 8 Vdc
  • Max. discharge current (Imax): 20 kA (8/20 µs per pole)
  • Nominal discharge current (In): 10 kA (C2)
  • Protection levels: 30 V (Line/Line), 650 V (Line/Earth) - C3 (10/1000 µs)
  • Impulse current (Iimp): 5 kA (D1 10/350 µs)
  • Cut-off frequencies: >115 MHz (-3 dB), >50 MHz (-1 dB) for 100 Ω system
  • Max. load current @25°C: 600 mA
  • Line resistance: 2 Ω
  • Technology: Gas discharge tube (GDT) + TVS diode
  • SPD configuration: 2 pairs, plug-in module
  • Connection: Screw terminal, 0.5–2.5 mm²
  • Mounting: 35 mm DIN rail (EN 60715)
  • Housing: Thermoplastic UL94 V-0
  • Operating/storage temperature: -40 to +85 °C
  • Protection rating: IP20
  • Failsafe mode: Short-circuit
  • Disconnection indicator: Transmission interrupt (default mode 2)
  • Spare module: DLA2M-06D2
  • Weight: 0.089 kg
  • Standards: IEC 61643-21 / EN 61643-21

Catalogs

No catalogs are available for this product.

See all of CITEL‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Intersolar 2026
Intersolar 2026

23-25 Jun 2026 Munich (Germany) Hall B4 - Stand 111

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.