video corpo

Type 2 surge arrester DG ME DC Y 1000 FM
for electrical installationsremote signalingDC power

Type 2 surge arrester - DG ME DC Y 1000 FM - DEHN + SÖHNE - for electrical installations / remote signaling / DC power
Type 2 surge arrester - DG ME DC Y 1000 FM - DEHN + SÖHNE - for electrical installations / remote signaling / DC power
Type 2 surge arrester - DG ME DC Y 1000 FM - DEHN + SÖHNE - for electrical installations / remote signaling / DC power - image - 2
Type 2 surge arrester - DG ME DC Y 1000 FM - DEHN + SÖHNE - for electrical installations / remote signaling / DC power - image - 3
Add to favorites
Compare this product

Characteristics

Type
type 2
Applications
remote signaling, for electrical installations, DC power
Other characteristics
with fault indication, modular, DC, plug-in
Voltage

1,250 V

Primary current

Max.: 20,000 A

Min.: 10,000 A

Description

Short description
Modular surge arrester for d.c. applications with floating remote signalling contact.

Key features
  • Universal combined arrester/ surge arrester consisting of a base part and a plug-in protection module
  • Device concept specifically developed for use in d.c. circuits
  • Powerful d.c. switching device (DCD) prevents fire damage caused by d.c. switching arcs
  • Use without additional backup fuse in defined applications
  • Operating state / fault indication by green / red indicator flag in the inspection window
  • Easy replacement of protection modules without tools due to module locking system with module release button
  • Floating remote signalling contact (changeover contact)
  • Modular, pluggable design; width of 6 DIN modules


Product details / Tender specifications
Surge protective device Type 2, DG M DC ACI 1250 FM
Modular, pluggable surge arrester for DC applications, width of 6 DIN modules
Mechanical operating / fault state indication
Type 2 arrester similar to EN / IEC 61643-41
Consisting of switch/spark gap combination
Specifically for use in DC charging equipment up to 1,250 V DC
Max. continuous operating voltage (+ --> -): 1250 V DC
Nominal discharge current (8/20 µs): 10 kA
Floating remote signalling contact as changeover contact
Vibration and shock-tested according to EN 60068
Fulfils IEC 61851-23

Technical details (table)
SPD classification similar to EN IEC 61643-41: Type 2
Nominal discharge current (8/20 µs) (In): 10 kA
Max. nominal impulse discharge current (8/20 µs) (Imax): 20 kA
Max. short circuit withstand capability (ISCCR): 5 kA
Type of remote signalling contact: changeover contact

Application / Functional description
Universal combined arrester with base part and plug-in protection module for protection of low-voltage consumer installations against surges.
Device concept and DCD switching device designed for safe operation in d.c. circuits and for use in DC charging equipment up to 1,250 V DC.
Mechanical operating / fault indication and easy tool-free replacement of protection modules.

Technical specifications
  • Brand: DEHN
  • Type / Model: DEHNguard M DC ACI 1250 FM
  • Part No.: 972150
  • GTIN (EAN): 4013364530850
  • Max. continuous operating voltage: 1250 V DC
  • Nominal discharge current (8/20 µs): 10 kA
  • Max. nominal impulse discharge current (8/20 µs): 20 kA
  • Max. short circuit withstand capability (ISCCR): 5 kA
  • Remote signalling: floating changeover contact
  • Width: 6 DIN modules (modular, pluggable)
  • Standards / Tests: EN / IEC 61643-41 (Type 2), EN 60068 (vibration/shock), IEC 61851-23
  • Packaging unit: 1 ST

Catalogs

No catalogs are available for this product.

See all of DEHN + SÖHNE‘s catalogs

Other DEHN + SÖHNE products

Surge protection for power supply systems