SIL 2 repeater X1-IS-AI-02-S
currentisolatedfor hazardous areas

SIL 2 repeater - X1-IS-AI-02-S - GM International S.p.A. - current / isolated / for hazardous areas
SIL 2 repeater - X1-IS-AI-02-S - GM International S.p.A. - current / isolated / for hazardous areas
SIL 2 repeater - X1-IS-AI-02-S - GM International S.p.A. - current / isolated / for hazardous areas - image - 2
Add to favorites
Compare this product

Characteristics

Options
current, isolated, for hazardous areas, SIL 2

Description

The Current Repeater Power Supply X1-IS-AI-02 module is a high integrity analog input interface suitable for applications requiring SIL 2 level in safety related systems for high risk industries. It provides an isolated supply for energizing conventional two-wire passive 4-20 mA transmitters located in Hazardous Area, while repeating the current to the system card. Two-wire active transmitters are also supported. The circuit allows bi-directional HART® communication for both passive and active devices. The module always sinks current and the Termination Board extends its use to source loops. An out-of-range current fault according to IEC 60947-5-6 NAMUR NE 43 standard is available with limits configurable through the optional Gateway. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction lever mechanism. This product requires a dedicated Termination Board.SIL 2 / SC 3Input from Zone 0 / Division 1Installation in Zone 2 / Division 2Loop disconnection to ease maintenance operations4-20 mA 2-wire Active-Passive InputHART® compatibleOut-of-range fault according to IEC 60947-5-6 NAMUR NE 43Input and Output short circuit proofHigh AccuracyThree port isolation, Input/Output/SupplyTechnical Specifications:Power Dissipation: 0.65 W (passive Tx), 1.05 W (active Tx) @ 24 Vdc with 20 mA, 24 Vdc + 250 Ω output, typical.System Supply: 24 Vdc nom (18 to 30 Vdc).Current Consumption: 23 mA @ 24 Vdc with 20 mA, typical.System Output: Current 4 to 20 mA. The module always sinks current and the Termination Board extends its use to source loops.Response time: ≤ 20 ms (4 to 20 mA or 20 to 4 mA).Current limitation: 25.5 mA typical.Maximum load: 600 Ω.Maximum voltage: 30 V.Minimum voltage: 15 V (including series resistance voltage drop).Field Input: Current 4 to 20 mA, passive or active Tx.Passive Tx line voltage: 15 V minimum @ 20 mA.Active Tx voltage drop: 6.5 V maximum @ 20 mA.Fault: An out-of-range fault with configurable limits is available on the common fault line.Performance Reference Conditions: 24 V supply, 24 V + 250 Ω output, 23 ± 1 °C ambient temperature.Linearity accuracy: ≤ ± 20 µA.Calibration accuracy: ≤ ± 20 µA.Temperature influence: ≤ ± 2 µA/°C.Isolation Test Voltage: Field In/System Out 2.5 kV; Field In/System Supply 2.5 kV; System Out/System Supply 500 V.Operating temperature: –40 to +70 °C.Storage temperature: –45 to +80 °C.Equipment: Associated apparatus and non-sparking electrical equipment.Safety parameters: Uo = 27.2 V, Io = 96 mA, Po = 463 mW at terminals A-Z. Uo = 1.1 V, Io = 56 mA, Po = 16 mW at terminals C-B. Ui = 30 V, Ii = 120 mA, Ci = 0 nF, Li = 0 nH at terminals C-B. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.Mounting: On custom Termination Board.Weight: about 55 g.Dimensions: Width 10 mm, Depth 80 mm, Height 120 mm.Channels: 1Status: ACTIVE

Catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.