Distribution transformer ECODIS20
cast resinfor industrial applicationsfor offshore applications

distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
distribution transformer
Add to favorites
Compare this product
 

Characteristics

Type
distribution
Configuration
cast resin
Applications
for industrial applications, for offshore applications, for mining equipment, for rolling mills
Electrical characteristics
three-phase, high-voltage
Electric power

Min.: 1 W

Max.: 100,000 W

Primary voltage

Min.: 1,000 V

Max.: 36,000 V

Secondary voltage

Min.: 100 V

Max.: 20,000 V

Description

TrafoELETTRO Dry type cast resin bi tension transformers SANERGRID Cast resin dry type transformers bi tension ECO DESIGN SANERGRID for fire protection and safety in your installation, no retention tank and no extinguishing system required. Recommended for hospitals, tunnels, train, supermarket Special Bi tension transformers from 100 kVA to 3150 kVA - 20 kV / 410 V - insulation classes 12 - 17.5 - 24 - 36 kV. The standard ranges from 160 kVA to 3150 kVA comply with the ECO DESIGN standard of COMMISSION REGULATION (EU) No 548/2014 of 21 May 2014. Ask us for a customized design for your specific needs. Standard configuration SANERGRID®: primary voltage: 20-15 kV, secondary voltage (empty): 410/230 V - neutral not reduced | ECODESIGN EU548-14 | Frequency: 50 Hz | Coupling: DYN 11 | Short-circuit voltage: 6% | Rated insulation voltage: 24 kV | Holding voltage at 50 Hz for 1 minute: 50 kV | Rated impulse withstand voltage: 125 kV | Natural cooling in ambient air (temperature at 40 ° C) | Isolation MT Coated / BT Impregnated | Thermal class F | MV +/- 2x2,5 dimming offset per bar | HTA connection on beaches | LV connection on tracks. Standard accessories included: 4 lifting rings | 4 swiveling rollers | Default thermal protection device: T-154 and 3 PT100 probes (or on request T119 with 6 PTC probes) | Ground terminal. Transformer performance attested by factory test certificate.

Catalogs

No catalogs are available for this product.

See all of Groupe SANERGRID‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.