1. Max. frequency response: 500KHz (duty cycle 50%)
2. Supports pulse mode, internal pulse mode, I/O control, position pressing mode, and torque mode
3. 3 Input signals : pulse, direction, offline (optocoupler isolation, 5V signal drive, current limiting resistor required for exceeding 5V)
4. 1 output signal : alarm (optocoupler isolation, output when there is no alarm)
5. Protection functions : overcurrent, overvoltage, undervoltage, motor phase loss