Characteristics

Technology
infrared, thermopile
Mounting
in metal housing
Output
0-10 V, 4-20 mA, RS-485, digital, USB
Electrical connection
M12 connector
Optical resolution
45:1
Protection level
IP65
Applications
for surface temperature measurement, high-temperature
Other characteristics
with digital display, programmable, with integrated electronics
Temperature

Min.: 300 °C
(572 °F)

Max.: 2,500 °C
(4,532 °F)

Spectral range

Min.: 4.6 µm

Max.: 4.9 µm

Response time

Min.: 0 ms

Max.: 100 ms

Description

Product overview:
The CellaTemp® PA 15 is a narrow-band, single-colour infrared pyrometer for near-surface temperature measurement on glass. The spectral sensitivity of 4.6–4.9 µm minimises influence from glass thickness or type and reduces sensitivity to atmospheric effects such as humidity changes.

Key features:
  • Measuring range: 300 to 2,500 °C (configurable in segments)
  • Focusable lenses for precise adjustment of measuring distance
  • Broadband anti-reflective precision optics
  • 4-digit red LED display readable at long distance
  • Test current output for diagnostics
  • Standard interfaces: digital I/O, two analogue outputs, USB and RS‑485


Versions / options:
  • Versions: CellaTemp PA 15 AF 1 and CellaTemp PA 15 AF 2
  • Typical ranges: AF 1 → 500–2500 °C; AF 2 → 300–1300 °C (version-dependent)
  • Standard focus (lens PZ 15.03): 0.8 m – ∞
  • Aiming/sighting: through-the-lens sighting, laser pilot light, video camera (models with camera)


Scope of delivery (examples):
  • Pyrometer CellaTemp PA
  • Connection cable VK 02/A (5 m)
  • Video cable VK 02/F (5 m) for camera models
  • USB cable VK 11/D (1.8 m)
  • CellaView software and quick manual


Technical specifications:
  • Measuring range: 300–2500 °C (in several segments)
  • Sensor: Thermopile
  • Spectral range: 4.6–4.9 µm
  • Response time t98: ≤ 100 ms
  • Measurement uncertainty: 0.75 % of reading [°C], minimum 3 K
  • Repeatability: 2 K
  • Temperature coefficient: 0.04 %/K
  • Resolution current output: 0.2 K + 0.03 % of selected range
  • Resolution interface: 0.1 K
  • Resolution display: 1 K
  • Standard lens (PZ 15.03): focus 0.8 m – ∞
  • Measuring field shape: round
  • Distance ratio (typical): AF 1 → 70:1; AF 2 → 45:1
  • Objective example: PZ 15.03
  • Measuring principle: single-colour
  • Analogue output: 0(4)–20 mA, switchable/scalable (≤ 500 Ω)
  • Analogue input: 0–10 V
  • Switching outputs: 2 × open collector 24 V DC, ≤ 30 mA
  • Switching inputs: 2 × up to 24 V
  • Interfaces: USB and RS‑485
  • Power supply: 24 V DC +10% / -20%
  • Current consumption: ≤ 175 mA (24 V DC)
  • Video output (camera models): Composite PAL, 1 Vpp, 75 Ω
  • Display: 4-digit red LED, digit height 8 mm; status display: 2 × LED; controls: 3 buttons
  • Connection: M12 thread, 8-pin
  • Operating ambient temperature: 0–65 °C
  • Storage temperature: -20–+80 °C
  • Permissible humidity: max. 95 % r.H. (non-condensing)
  • Dimensions: Ø 65 mm × 220 mm (max. 277 mm)
  • Housing: Stainless steel V2A (1.4305)
  • Protection class: IP 65 (DIN 40050)
  • Weight: approx. 0.9 kg
  • Adjustable parameters (selection): measuring range, measured variable and scaling of analogue I/O, smoothing filter, memory modes and hold times, emissivity, transmittance, reflected ambient radiation compensation, alarm limits and modes, linearization, LED status, simulation of current/temperature, temperature unit °C/°F; camera models: TBC and white balance
  • Functions: overtemperature signal (if internal temp > 80 °C analogue output > 20.5 mA), service function (simulation of measured value or current), ATD (Automatic Temperature Detection) for discontinuous processes

Catalogs

No catalogs are available for this product.

See all of Keller Pyrometer Systems‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

HärtereiPraxis 2026
HärtereiPraxis 2026

22-24 Jun 2026 Kamp-Lintfort im Wellings Parkhotel (Germany)

Shenzhen International Semiconductor & IC Exhibition
Shenzhen International Semiconductor & IC Exhibition

9-11 Sep 2026 Shenzhen (China)

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.