Product overview:The CellaTemp® PA 15 is a narrow-band, single-colour infrared pyrometer for near-surface temperature measurement on glass. The spectral sensitivity of 4.6–4.9 µm minimises influence from glass thickness or type and reduces sensitivity to atmospheric effects such as humidity changes.
Key features:- Measuring range: 300 to 2,500 °C (configurable in segments)
- Focusable lenses for precise adjustment of measuring distance
- Broadband anti-reflective precision optics
- 4-digit red LED display readable at long distance
- Test current output for diagnostics
- Standard interfaces: digital I/O, two analogue outputs, USB and RS‑485
Versions / options:- Versions: CellaTemp PA 15 AF 1 and CellaTemp PA 15 AF 2
- Typical ranges: AF 1 → 500–2500 °C; AF 2 → 300–1300 °C (version-dependent)
- Standard focus (lens PZ 15.03): 0.8 m – ∞
- Aiming/sighting: through-the-lens sighting, laser pilot light, video camera (models with camera)
Scope of delivery (examples):- Pyrometer CellaTemp PA
- Connection cable VK 02/A (5 m)
- Video cable VK 02/F (5 m) for camera models
- USB cable VK 11/D (1.8 m)
- CellaView software and quick manual
Technical specifications:- Measuring range: 300–2500 °C (in several segments)
- Sensor: Thermopile
- Spectral range: 4.6–4.9 µm
- Response time t98: ≤ 100 ms
- Measurement uncertainty: 0.75 % of reading [°C], minimum 3 K
- Repeatability: 2 K
- Temperature coefficient: 0.04 %/K
- Resolution current output: 0.2 K + 0.03 % of selected range
- Resolution interface: 0.1 K
- Resolution display: 1 K
- Standard lens (PZ 15.03): focus 0.8 m – ∞
- Measuring field shape: round
- Distance ratio (typical): AF 1 → 70:1; AF 2 → 45:1
- Objective example: PZ 15.03
- Measuring principle: single-colour
- Analogue output: 0(4)–20 mA, switchable/scalable (≤ 500 Ω)
- Analogue input: 0–10 V
- Switching outputs: 2 × open collector 24 V DC, ≤ 30 mA
- Switching inputs: 2 × up to 24 V
- Interfaces: USB and RS‑485
- Power supply: 24 V DC +10% / -20%
- Current consumption: ≤ 175 mA (24 V DC)
- Video output (camera models): Composite PAL, 1 Vpp, 75 Ω
- Display: 4-digit red LED, digit height 8 mm; status display: 2 × LED; controls: 3 buttons
- Connection: M12 thread, 8-pin
- Operating ambient temperature: 0–65 °C
- Storage temperature: -20–+80 °C
- Permissible humidity: max. 95 % r.H. (non-condensing)
- Dimensions: Ø 65 mm × 220 mm (max. 277 mm)
- Housing: Stainless steel V2A (1.4305)
- Protection class: IP 65 (DIN 40050)
- Weight: approx. 0.9 kg
- Adjustable parameters (selection): measuring range, measured variable and scaling of analogue I/O, smoothing filter, memory modes and hold times, emissivity, transmittance, reflected ambient radiation compensation, alarm limits and modes, linearization, LED status, simulation of current/temperature, temperature unit °C/°F; camera models: TBC and white balance
- Functions: overtemperature signal (if internal temp > 80 °C analogue output > 20.5 mA), service function (simulation of measured value or current), ATD (Automatic Temperature Detection) for discontinuous processes