Product description:The CellaTemp® PA 50 is a digital two-colour pyrometer for contactless temperature measurement in the range 500–1,400 °C. The two-colour measuring method reduces sensitivity to disturbances from dust, dirty protective windows or changing surface emissivity. For precise aiming the instrument can be equipped with through-the-lens sighting, a laser pilot light or a camera module.
Special features:- Measuring range 500 to 1,400 °C
- Focusable interchangeable lenses for exact adjustment of measuring distance
- Broadband anti-reflective precision optics
- 4-digit red LED display, digit height 8 mm, readable at distance
- Test current output for diagnostic function
- Standard interfaces: analogue output and USB/RS‑485
Measurement parameters:- Measuring range: 500–1,400 °C
- Sensor: double photodiode
- Spectral range: 0.95 / 1.55 µm
- Response time t98: ≤ 30 ms
- Measurement uncertainty: 1 % of temperature reading
- Repeatability: ±2 K
- Temperature coefficient: 0.05 %/K
- Resolution current output: 0.2 K + 0.03 % of selected range
- Resolution interface: 0.1 K
- Resolution display: 1 K
Optical variants (lenses):- Standard lens PZ 20.01: focusing 0.4 m – ∞
- Close‑up lens PZ 20.03: focusing 0.2 m – 0.4 m
- Wide‑angle lens PZ 20.05: focusing 0.2 m – ∞
- Telephoto lens PZ 20.06: focusing 1.2 m – ∞
Electrical parameters:- Analog output: 0(4)–20 mA, linear, switchable, scalable; R ≤ 500 Ω
- Analog input: 0–10 V
- Switching outputs: 2 × open collector 24 V DC, ≤ 30 mA
- Switching inputs: 2 × up to 24 V
- Interfaces: USB, RS‑485
- Power supply: 24 V DC +10 % / −20 %; current consumption ≤ 175 mA
Camera:Video output: Composite PAL, 1 Vpp, 75 Ω (for models with built‑in camera)
Features:- Sighting: through‑the‑lens, laser pilot light or camera
- Display: 4‑digit red LED
- Status display: 2 × LED
- Control: 3 buttons
General parameters:- Connection: M12, 8‑pin
- Ambient temperature: 0 – 65 °C
- Storage temperature: −20 – +80 °C
- Permissible humidity: up to 95 % r.H. (non‑condensing)
- Dimensions: Ø 65 mm × 220 mm (max. 277 mm)
- Housing: stainless steel V2A (1.4305)
- Protection class: IP 65 (DIN 40050)
- Weight: approx. 0.9 kg
Adjustable parameters:- Measuring range and measured variable
- Analogue input/output scaling
- Smoothing filter; memory operation mode; memory hold time
- Emissivity; transmittance; compensation of reflected ambient radiation
- Alarm thresholds and alarm contact modes
- ATD function parameters (optional); linearization
- LED status indication; simulation of current and temperature
- Temperature unit °C/°F; measurement channel selection (two‑colour, single‑colour 1, single‑colour 2)
- Contamination monitoring threshold; camera functions: TBC and white balance (for models with camera)
Functions:- Overtemperature signal: if internal temperature > 80 °C the analogue output > 20.5 mA
- Service function: simulation of measured value or current signal
- ATD (Automatic Temperature Detection): automatic detection for discontinuous processes
Scope of delivery:- Pyrometer CellaTemp® PA 50
- Connection cable VK 02/A (5 m)
- Video cable VK 02/F (5 m) for camera models
- USB cable VK 11/D (1.8 m)
- Software CellaView
- Short manual
Software:CellaView
Technical specifications:- Model: CellaTemp® PA 50
- Measuring range: 500–1,400 °C
- Spectral range: 0.95 / 1.55 µm
- Response time: ≤ 30 ms
- Measurement uncertainty: 1 % of reading
- Outputs: analogue 0(4)–20 mA, USB, RS‑485
- Power supply: 24 V DC ±
- Protection class: IP65
- Housing: stainless steel V2A
- Weight: approx. 0.9 kg