Fiber optic pyrometer CellaTemp® PA 31
with LED displayRS485USB

Fiber optic pyrometer - CellaTemp® PA 31 - Keller Pyrometer Systems - with LED display / RS485 / USB
Fiber optic pyrometer - CellaTemp® PA 31 - Keller Pyrometer Systems - with LED display / RS485 / USB
Fiber optic pyrometer - CellaTemp® PA 31 - Keller Pyrometer Systems - with LED display / RS485 / USB - image - 2
Fiber optic pyrometer - CellaTemp® PA 31 - Keller Pyrometer Systems - with LED display / RS485 / USB - image - 3
Fiber optic pyrometer - CellaTemp® PA 31 - Keller Pyrometer Systems - with LED display / RS485 / USB - image - 4
Add to favorites
Compare this product

Characteristics

Technology
fiber optic
Display
with LED display
Communication
USB, RS485, analog output, PROFIBUS
Protection level
IP65
Configuration
fixed
Applications
industrial, for harsh environments
Other characteristics
precision, with fiber optic
Temperature

Max.: 3,000 °C
(5,432 °F)

Min.: 550 °C
(1,022 °F)

Spectral range

Max.: 1.06 µm

Min.: 0.78 µm

Response time

2 ms, 50 ms

Description

Article description
The CellaTemp® PA 31 is a digital pyrometer with a fibre optic cable for measuring temperatures between 550 and 2,500 °C. The pyrometer is equipped with a separate optical measuring head and a fibre optic cable. The fibre optic cable and measuring head are insensitive to interference from electromagnetic radiation and can be used in ambient temperatures up to 250 °C without cooling. The variant with separate optical measuring head has advantages especially in confined spaces.

Special features
  • Measuring range 550 to 2,500 °C
  • Focusable interchangeable lenses for exact adjustment of the measuring distance
  • Broadband anti-reflective precision lenses
  • Short measuring wavelengths
  • LED display can be read from a great distance
  • Test current output for the diagnostic function
  • Standard feature: analogue output and USB/RS 485 interface
  • Measuring head and fibre optic cable heat resistant up to 250 °C

Versions / Variants
CellaTemp PA 31 AF 11
CellaTemp PA 31 AF 21
CellaTemp PA 31 AF 22
CellaTemp PA 31 AF 901

Measuring ranges by variant
AF 22: 550 - 2500 °C
AF 901: 700 - 3000 °C

Focus distance by variant
AF 11: 0,2 m - ∞
AF 21: 0,12 m - ∞
AF 22: 0,033 - 0,045 m
AF 901: 0,5 m - ∞

Measuring field shape
round

Distance ratio by variant
AF 11: 190 : 1
AF 21: 100 : 1
AF 22: 50 : 1
AF 901: 340 : 1

Measuring head (examples)
AF 11 → Measuring head PA 41.01
AF 21 → Measuring head PA 41.05
AF 22 → Measuring head PZ 41.18
AF 901 → Measuring head PA 41.02

Technical Data — Measurement parameters
Measuring range: 550 - 3000 °C in several segments
Sensor: Photo diode
Spectral range: 0.78 - 1.06 µm
Response time t98: Measuring range 550 - 2500 °C: ≤ 50 ms (T > 600 °C) and ≤ 2 ms (T > 800 °C). Measuring range 700 - 3000 °C: ≤ 50 ms (T > 750 °C) and ≤ 2 ms (T > 950 °C).
Measurement uncertainty: 0.75 % of temp. reading [°C]
Repeatability: 2 K
Temperature coefficient: 0.05 %/K
Resolution current output: 0.2 K + 0.03 % of selected range
Resolution interface: 0.1 K
Resolution display: 1 K

Optical variants
Measuring heads (550 - 2500 °C): PA 41.01 (M30): focusing 0.2 m - ∞; PA 41.05 (M16): focusing 0.12 m - ∞; PZ 41.18 (M16): focusing 0.033 - 0.045 m.
Measuring head (700 - 3000 °C): PA 41.02 (M16): focusing 0.5 m - ∞.

Electrical parameters
Analog output: 0(4) - 20 mA linear, switchable, scalable
Resistance: ≤ 500 Ω
Analog input: 0 - 10 V
Switching output: 2 x Open Collector 24 V DC, ≤ 30 mA
Switching input: 2 x to 24 V
Interface: USB
Interface: RS 485
Power supply: 24 V DC +10 % / -20 %
Current consumption: ≤ 175 mA for 24 V DC
Connection: M12 thread 8-pin connection

Features
Sighting option: Laser pilot light
Display: 4-digit LED display red, digit-height 8 mm
Status display: 2 x LED
Control elements: 3 buttons

General parameters
Ambient temperature: Electronic: 0 - 65 °C; Measuring head: 250 °C
Storage temperature: -20 - +80 °C
Permissible humidity: 95 % r.H. max. (non-condensing)
Dimension: Electronic: Ø 65 mm x 187 mm; Measuring head: depending on the type
Housing: Stainless steel V2A (1.4305)
Protection class: IP 65 acc. to DIN 40050
Weight: approx. 0.9 kg

Adjustable parameters
  • Measuring range
  • Measured variable and scale of analogue input and output signals
  • Smoothing filter
  • Memory operation mode
  • Hold time of the memory
  • Emissivity
  • Transmittance
  • Compensation of the reflected ambient radiation
  • Limits and operating mode of the alarm contacts
  • Parameters of the ATD function (optional)
  • Linearization function
  • Status display of the LEDs
  • Simulation of current and temperature
  • Temperature unit °C/°F

Functions
Overtemperature signal: if the internal temperature exceeds 80 °C the analogue output shows a value > 20.5 mA
Service function: Simulation of a measured value or a current signal

Scope of delivery
Pyrometer CellaTemp PA
Connection cable VK 02/A (5 m)
Measuring head
USB cable VK 11/D (1.8 m)
Software CellaView
Manual (short)
* The fibre optic cable must be ordered separately.

Software
CellaView

Measuring field examples (Measuring distance — Measuring field diameter)
0.00 mm — 21.50 mm
8.00 mm — 20.68 mm
16.00 mm — 19.86 mm
24.00 mm — 19.05 mm
32.00 mm — 18.23 mm
40.00 mm — 17.41 mm
48.00 mm — 16.59 mm
56.00 mm — 15.77 mm
64.00 mm — 14.96 mm
72.00 mm — 14.14 mm
80.00 mm — 13.32 mm
88.00 mm — 12.50 mm
96.00 mm — 11.69 mm
104.00 mm — 10.87 mm
112.00 mm — 10.05 mm
120.00 mm — 9.23 mm
128.00 mm — 8.41 mm
136.00 mm — 7.60 mm
144.00 mm — 6.78 mm
152.00 mm — 5.96 mm
160.00 mm — 5.14 mm
168.00 mm — 4.32 mm
176.00 mm — 3.51 mm
184.00 mm — 2.69 mm
192.00 mm — 1.87 mm

Caractéristiques / spécifications techniques
  • Model: CellaTemp® PA 31
  • Measuring range: 550 - 3000 °C (depending on segment/version)
  • Spectral range: 0.78 - 1.06 µm
  • Measurement uncertainty: 0.75 % of temperature reading
  • Response time: ≤ 50 ms or ≤ 2 ms depending on temperature and range
  • Outputs/interfaces: 0(4)-20 mA, USB, RS 485, relay inputs/outputs
  • Power supply: 24 V DC (+10 % / -20 %)
  • Ambient temperature (electronics): 0 - 65 °C; measuring head up to 250 °C
  • Housing: Stainless steel V2A (1.4305); Protection class IP65
  • Display: 4-digit red LED (8 mm)
  • Weight: approx. 0.9 kg
  • Scope of delivery: pyrometer, connection cable, measuring head, USB cable, software and short manual (fibre optic cable ordered separately)

Catalogs

No catalogs are available for this product.

See all of Keller Pyrometer Systems‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

HärtereiPraxis 2026
HärtereiPraxis 2026

22-24 Jun 2026 Kamp-Lintfort im Wellings Parkhotel (Germany)

Shenzhen International Semiconductor & IC Exhibition
Shenzhen International Semiconductor & IC Exhibition

9-11 Sep 2026 Shenzhen (China)

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.