Digital pyrometer CellaTemp® PA 10
°C50:1RS485

Digital pyrometer - CellaTemp® PA 10 - Keller Pyrometer Systems - °C / 50:1 / RS485
Digital pyrometer - CellaTemp® PA 10 - Keller Pyrometer Systems - °C / 50:1 / RS485
Digital pyrometer - CellaTemp® PA 10 - Keller Pyrometer Systems - °C / 50:1 / RS485 - image - 2
Digital pyrometer - CellaTemp® PA 10 - Keller Pyrometer Systems - °C / 50:1 / RS485 - image - 3
Add to favorites
Compare this product

Characteristics

Display
digital
Units of measurement
°C
Optical resolution
50:1
Communication
USB, RS485, analog output
Protection level
IP65
Configuration
fixed
Applications
industrial, for harsh environments
Other characteristics
stainless steel, non-contact, optical
Temperature

Min.: 0 °C
(32 °F)

Max.: 1,000 °C
(1,832 °F)

Spectral range

Min.: 8 µm

Max.: 14 µm

Response time

30 ms

Description

Overview
The CellaTemp® PA 10 is a digital pyrometer for non-contact temperature measurement from 0 to 1,000 °C. Its wide measuring span and interchangeable optics allow use in varied industrial applications on primarily non-metallic measuring objects. Options for through-the-lens sighting, laser pilot light or an integrated video camera simplify accurate target alignment. A rear 4‑digit red LED display is readable from a distance and shows measured temperature or modified parameter values when settings are changed via rear buttons.

Key features
  • Measuring range: 0 – 1,000 °C
  • Thermopile sensor, spectral range 8 – 14 µm
  • Focusable interchangeable precision lenses (PZ series)
  • High distance ratio variants: AF 1 ≈ 50:1, AF 2 ≈ 48:1
  • 2 × analogue outputs (0(4)–20 mA), digital I/O, USB and RS‑485 interfaces
  • Stainless steel housing, protection class IP65


Versions & optics
  • Versions: CellaTemp PA 10 AF 1 (focus 0.3 m – ∞) and AF 2 (focus 0.15 – 0.3 m)
  • Standard lens: PZ 10.01 (0.3 m – ∞)
  • Close-up lens: PZ 10.05 (0.15 m – 0.3 m)
  • Sighting: through-the-lens sighting, laser pilot light, video camera (optional)


Measurement parameters (selected)
  • Response time t98: ≤ 30 ms
  • Measurement uncertainty: 1 % of reading [°C], min. 2 K
  • Repeatability: 1 K
  • Resolution display: 0.1 K (< 200 °C) / 1 K (≥ 200 °C)
  • Resolution interface: 0.1 K
  • Resolution current output: 0.2 K + 0.03 % of selected range


Optical / measuring field
  • Measuring field shape: round
  • Examples (distance → spot diameter): 0.00 mm → 24.00 mm; 12.00 mm → 23.28 mm; 24.00 mm → 22.56 mm; ... ; 300.00 mm → 6.00 mm
  • Distance ratios: AF 1 = 50 : 1, AF 2 = 48 : 1


Electrical & interfaces
  • Analogue outputs: 2 × 0(4)–20 mA (linear, switchable, scalable), load ≤ 500 Ω
  • Analogue input: 0 – 10 V
  • Switching outputs: 2 × Open Collector 24 V DC, ≤ 30 mA
  • Switching inputs: 2 × up to 24 V
  • Interfaces: USB, RS‑485
  • Power supply: 24 V DC (+10 % / −20 %), current consumption ≤ 175 mA


Camera (optional)
  • Video output (camera model): Composite PAL, 1 Vpp, 75 Ω
  • Camera aids visual alignment of the measuring spot


Display, controls & functions
  • Rear 4‑digit red LED display (digit height 8 mm), 2 status LEDs
  • Control: 3 rear buttons; display shows current value or changed parameters
  • Overtemperature signal: if internal temperature > 80 °C analogue output > 20.5 mA
  • Service function: simulation of measured value or current signal
  • ATD (Automatic Temperature Detection) for discontinuous processes (optional)


General parameters
  • Connection: M12 thread 8‑pin connector
  • Ambient temperature (operation): 0 – 65 °C; storage: −20 – +80 °C
  • Permissible humidity: ≤ 95 % r.H. (non‑condensing)
  • Dimensions: Ø 65 mm × 220 mm (max. 277 mm)
  • Housing: stainless steel V2A (1.4305)
  • Protection class: IP65 (DIN 40050)
  • Weight: approx. 0.9 kg


Adjustable parameters
  • Measuring range and scaling of analogue I/O
  • Smoothing filter; memory mode and hold time
  • Emissivity and transmittance; compensation of reflected ambient radiation
  • Alarm limits and operating mode; linearization
  • Simulation of current/temperature; temperature unit °C/°F
  • Camera models: TBC function, white balance


Scope of delivery
  • Pyrometer CellaTemp PA 10
  • Connection cable VK 02/A (5 m)
  • USB cable VK 11/D (1.8 m)
  • Video cable VK 02/F (5 m) for camera models
  • Software CellaView; short manual


Technical summary
  • Model: CellaTemp® PA 10
  • Measuring range: 0 – 1,000 °C
  • Sensor: Thermopile; spectral range 8 – 14 µm
  • Response time: ≤ 30 ms (t98)
  • Accuracy: 1 % of reading, min. 2 K; repeatability 1 K
  • Analogue outputs: 2 × 0(4)–20 mA; interfaces USB, RS‑485
  • Protection: IP65; housing stainless steel; weight ~0.9 kg

Catalogs

No catalogs are available for this product.

See all of Keller Pyrometer Systems‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

HärtereiPraxis 2026
HärtereiPraxis 2026

22-24 Jun 2026 Kamp-Lintfort im Wellings Parkhotel (Germany)

Shenzhen International Semiconductor &amp; IC Exhibition
Shenzhen International Semiconductor &amp; IC Exhibition

9-11 Sep 2026 Shenzhen (China)

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.