DescriptionThe CellaTemp® PA 41 is a digital two-colour pyrometer with a fibre optic cable for measuring temperatures between 700 and 3,000 °C. The two-colour pyrometer is equipped with a separate optical measuring head and a fibre optic cable. The fibre optic cable and measuring head are insensitive to interference from electromagnetic radiation and can be used in ambient temperatures up to 250 °C without cooling. The variant with separate optical measuring head offers advantages in confined spaces.
Special features- Measuring ranges 700 to 3,000 °C
- Focusable interchangeable lenses for exact adjustment of the measuring distance
- Broadband anti-reflective precision lenses
- Short measuring wavelengths
- LED display can be read from a great distance
- Test current output for the diagnostic function
- Standard feature: analogue output and USB/RS 485 interface
- Measuring head and fibre optic cable heat resistant up to 250 °C
Optical variants / Versions (selection)Measuring ranges available: 700 - 1800 °C; 800 - 2400 °C; 900 - 3000 °C; 1100 - 3000 °C
Measuring heads and focusing ranges:
PA 41.01 (M30): focusing 0.2 m - ∞ (used for ranges 800-2400 °C, 900-3000 °C and 700-1800 °C)
PA 41.05 (M16): focusing 0.12 m - ∞
PZ 41.18 (M16): focusing 0.033 - 0.045 m
PZ 41.05 (M30): focusing 0.3 m - ∞ (additionally for 800 - 2400 °C)
PA 41.02 (M16): focusing 0.5 m - ∞ (measuring range 1100 - 1300 °C)
Distance ratios (examples by version): AF 111 = 190 : 1; AF 121 = 100 : 1; AF 221 = 50 : 1; AF 190 = 175 : 1; AF 211 = 110 : 1; AF 222 = 36 : 1; AF 901 = 340 : 1
Electrical parametersAnalog output: 0(4) - 20 mA linear, switchable, scalable
Resistance: ≤ 500 Ω
Analog input: 0 - 10 V
Switching output: 2 x Open Collector 24 V DC, ≤ 30 mA
Switching input: 2 x to 24 V
Interfaces: USB; RS 485
Power supply: 24 V DC +10% / -20%
Current consumption: ≤ 175 mA for 24 V DC
FeaturesSighting option: Laser pilot light
Display: 4-digit red LED display, digit-height 8 mm
Status display: 2 x LED
Control elements: 3 buttons
General parametersConnection: M12 thread 8-pin connection
Ambient temperature: Electronic: 0 - 65 °C; Measuring head: up to 250 °C
Storage temperature: -20 - +80 °C
Permissible humidity: 95 % r.H. max. (non-condensing)
Dimensions: Electronic: Ø 65 mm x 187 mm; Measuring head: depending on the type
Housing: Stainless steel V2A (1.4305)
Protection class: IP 65 (acc. to DIN 40050)
Weight: approx. 0.9 kg
Measurement parameters (selection)Measuring range: 700 - 3000 °C in several segments
Sensor: Double photo diode
Spectral range: 0.95 / 1.05 µm
Response time t98: ≤ 20 ms (depending on selected measuring range and temperature thresholds)
Measurement uncertainty: 1.5 % of temperature reading [°C]
Repeatability: 3 K
Temperature coefficient: 0.05 %/K
Resolution current output: 0.2 K + 0.03 % of selected range
Resolution interface: 0.1 K
Resolution display: 1 K
Adjustable parameters- Measuring range selection
- Measured variable and scale of analogue input and output signals
- Smoothing filter
- Memory operation mode and hold time
- Emissivity and transmittance
- Compensation of reflected ambient radiation
- Limits and operating mode of alarm contacts
- Parameters of the ATD function (optional)
- Linearization function
- LED status display settings
- Simulation of current and temperature
- Temperature unit °C/°F
- Measurement channel: two-colour, single-colour 1 and single-colour 2
- Threshold level of the contamination monitoring
FunctionsOvertemperature signal: if the internal temperature exceeds 80 °C the analogue output shows a value > 20.5 mA
Service function: simulation of a measured value or a current signal
Scope of deliveryPyrometer CellaTemp PA
Connection cable VK 02/A (5 m)
Measuring head
USB cable VK 11/D (1.8 m)
Software CellaView
Manual (short)
* Note: The fibre optic cable must be ordered separately.
SoftwareCellaView
Caractéristiques / spécifications techniques- Model: CellaTemp® PA 41
- Measuring principle: two-colour
- Measuring ranges (examples): 700 - 1800 °C; 800 - 2400 °C; 900 - 3000 °C; 1100 - 3000 °C
- Spectral range: 0.95 / 1.05 µm
- Response time (t98): ≤ 20 ms (depending on range & temperature)
- Accuracy: 1.5 % of reading
- Repeatability: 3 K
- Outputs / Interfaces: 0(4)-20 mA, USB, RS 485
- Power supply: 24 V DC (+10% / -20%)
- Ambient conditions: Electronic 0 - 65 °C; Measuring head up to 250 °C
- Housing: Stainless steel V2A (1.4305), Protection class IP65
- Weight: approx. 0.9 kg