Power distribution substation YBTD
compactmodularfor photovoltaic applications

Power distribution substation - YBTD - Ningbo Tianan (Group) CO.,Ltd. - compact / modular / for photovoltaic applications
Power distribution substation - YBTD - Ningbo Tianan (Group) CO.,Ltd. - compact / modular / for photovoltaic applications
Power distribution substation - YBTD - Ningbo Tianan (Group) CO.,Ltd. - compact / modular / for photovoltaic applications - image - 2
Power distribution substation - YBTD - Ningbo Tianan (Group) CO.,Ltd. - compact / modular / for photovoltaic applications - image - 3
Power distribution substation - YBTD - Ningbo Tianan (Group) CO.,Ltd. - compact / modular / for photovoltaic applications - image - 4
Power distribution substation - YBTD - Ningbo Tianan (Group) CO.,Ltd. - compact / modular / for photovoltaic applications - image - 5
Power distribution substation - YBTD - Ningbo Tianan (Group) CO.,Ltd. - compact / modular / for photovoltaic applications - image - 6
Power distribution substation - YBTD - Ningbo Tianan (Group) CO.,Ltd. - compact / modular / for photovoltaic applications - image - 7
Power distribution substation - YBTD - Ningbo Tianan (Group) CO.,Ltd. - compact / modular / for photovoltaic applications - image - 8
Add to favorites
Compare this product

Characteristics

Fonction
power distribution
Options and accessories
compact, modular, for photovoltaic applications
Rated voltage

270 kV, 690 kV, 40,500 kV

Current

630 A, 1,250 A

Description

General
The YBTD series substation is designed for integration with wind power and photovoltaic generation. It provides a modular housing, configurable HV/LV compartments and transformer options to suit on-site requirements.

Service conditions
  • Altitude: ≤ 1000 m
  • Ambient temperature: max +40°C, min -25°C
  • Max daily average temperature: ≤ 35°C
  • Max annual average temperature: ≤ 25°C
  • Max daily temperature difference: ≤ 25°C
  • Solar radiation: ≤ 1000 W/m²
  • Wind speed: ≤ 34 m/s
  • Icing thickness: ≤ 20 mm
  • Pollution level: Class II
  • Installation tilt: ≤ 3°
  • Seismic: horizontal ground acceleration 0.2 g; vertical 0.1 g
  • Installation site: free from fire, explosion risk, severe chemical corrosion or strong vibration


Structure features
  • Housing structure: Substation skeleton manufactured from channel and angle steel. Shell options: cold-rolled steel plate, stainless steel, composite color plate, aluminium-alloy plate or glass-fibre reinforced cement. Steel-plate partitions between compartments and integrated lighting. Double-layer cover for thermal control. Transformer room configurable as open (radiator outdoors) or closed (independent chamber with automatic exhaust). Low-temperature seals on doors and high-temperature surface coating for UV resistance.
  • HV unit: High-voltage switchgear options (e.g. XGTD9, HXGN11, XGTD6, (H)XGTD10). Designs prioritise compact layout, safe interlocks and ease of installation and maintenance.
  • Transformer unit: Use of S9-M / S11-M oil-immersed transformers or SCB dry-type transformers. Transformer room supports natural or forced ventilation. Flexible connections on LV terminals protect bushings and prevent oil leakage.
  • LV unit: LV switchgear choices include GGD, GCS and GCK series. Metering, protection and automatic power‑factor compensation can be configured per project requirements.
  • Distribution network automation unit: Terminal automation equipment optimised for harsh environments: wide temperature tolerance, dual-fibre ring communication, high immunity to interference, vibration, humidity and lightning, low power consumption. Provides automatic monitoring interfaces for wind and PV transformers.


Technical data
Rated HV voltage: 40.5 kV
Rated frequency: 50 / 60 Hz
Rated HV current options: 630 A / 1250 A
1 min power-frequency withstand voltage (ground/phase): 95 / 118 kV
Lightning impulse withstand voltage (ground/phase): 185 / 215 kV
Rated short-time withstand current: 20 kA/2 s ; 25 kA/4 s
Rated peak withstand current: 50 kA ; 63 kA
Rated short-circuit current examples: 31.5 kA ; 63 kA
Rated short-circuit breaking current examples: 31.5 kA ; 25 kA

LV rated voltage: 690 / 270 V
Main circuit rated current: 1600 ~ 3300 A
Rated ultimate short-circuit breaking capacity: 50 kA
Rated short-circuit breaking capacity: 40 kA
Rated short-time withstand current (LV): 40 kA/1 s

Transformer rated capacity: 1000 ~ 5500 kVA
Impedance voltage: 6.5 %
Tap range: ±2×2.5 % ; ±5 %
Connection group: D, yn11 or Y, d11/d11

Enclosure protection: HV room IP33; LV room IP33; Transformer room IP23
Sound level: ≤ 55 dB

Note
Parameters shown are for reference. Site-specific customization and engineering options are available on request.

Characteristics / technical specifications
  • Series: YBTD substation for wind and photovoltaic integration
  • Rated HV voltage: 40.5 kV
  • Rated frequency: 50 / 60 Hz
  • HV rated current options: 630 A, 1250 A
  • LV rated voltage: 690 / 270 V
  • LV main circuit rated current range: 1600–3300 A
  • Transformer capacity range: 1000–5500 kVA
  • Transformer impedance: 6.5 %
  • Tap range: ±2×2.5 % ; ±5 %
  • Protection degrees: HV/LV IP33, Transformer IP23
  • Noise level: ≤ 55 dB