General35 kV and below oil-immersed transformers are standard equipment in power distribution and generation interfaces. They convert primary high voltage to secondary usable voltage by electromagnetic induction. Core and windings are immersed in insulating oil, which provides electrical insulation and transfers heat via oil circulation for cooling.
Structural characteristics- Winding structure: HV windings use multi-layer cylindrical continuous designs to optimize mechanical stress distribution; LV windings employ cylindrical or spiral constructions for balanced ampere-turn distribution and high short-circuit strength.
- Core: High-quality cold-rolled grain-oriented silicon steel sheets with butt-lapped (oblique seam) stacking to improve magnetic and mechanical performance. Options include electrical steel strip or amorphous alloy cores with differing loss characteristics.
- Cooling system: Insulating oil is the primary cooling medium. Cooling methods supported include oil-immersed natural cooling (ONAN), oil-immersed forced air cooling (ONAF), oil-immersed water cooling, and forced oil circulation.
- Protection devices: Gas relay, conservator/oil cushion, explosion-proof pipe/valve and other protections; gas relays detect internal faults, conservators regulate oil volume, explosion-proof devices relieve pressure.
Application- Power systems: Widely used in distribution and substation equipment up to 35 kV for voltage step-down to user levels.
- Industrial installations: Supply medium and high power for industrial machinery and process plants.
- Railway systems: Step-down and isolation for traction and auxiliary systems where applicable.
- New energy integration: Used in wind and photovoltaic plants to connect generation to the grid.
- Urban distribution: Substations and distribution rooms in cities for residential and commercial supply.
Product Features- Cost-effective solution for comparable ratings versus dry-type designs.
- Effective thermal performance: oil cooling reduces operating temperature.
- High insulation capability due to oil-impregnated insulation system.
- Wide applicability across typical distribution voltages up to 35 kV.
Technical Parameter- Rated voltage: up to 35 kV.
- Rated capacity: commonly 630–3150 kVA; standard designs and data sheets cover many capacities up to 31,500 kVA.
- Frequency: 50 Hz / 60 Hz.
- Cooling methods: ONAN, ONAF, oil-immersed water cooling, forced oil circulation, etc.
- Insulation: oil-impregnated insulation.
- Winding: HV multi-layer cylindrical continuous; LV cylindrical/spiral; designed for mechanical strength and short-circuit resistance.
- Core material: cold-rolled grain-oriented silicon steel (optionally amorphous alloy).
- Protection: gas relay, conservator, explosion-proof valve; OLTC variants available for on-load tap changing.
Data Sheet of Typical Products — energy efficiency level (selected rows)Rated capacity (kVA) | Level I No-Load Loss (kW) | Level I Load Loss (75°C) (kW) | Level II No-Load Loss (kW) | Level II Load Loss (75°C) (kW) | Level III No-Load Loss (kW) | Level III Load Loss (75°C) (kW) | Short circuit impedance (%)
3150 | 1.7 | 20.7 | 2.0 | 20.7 | 2.4 | 21.9 | 7
4000 | 2.0 | 24.6 | 2.3 | 24.6 | 2.9 | 25.9 | 7
5000 | 2.4 | 28.2 | 2.8 | 28.2 | 3.5 | 29.7 | 7
6300 | 2.9 | 31.5 | 3.4 | 31.5 | 4.2 | 33.3 | 8
8000 | 4.0 | 34.6 | 4.7 | 34.6 | 5.8 | 36.5 | 8
10000 | 4.8 | 40.8 | 5.7 | 40.8 | 7.0 | 43.0 | 8
12500 | 5.5 | 48.4 | 6.5 | 48.4 | 8.0 | 51.1 | 8
16000 | 6.7 | 59.2 | 7.9 | 59.2 | 9.7 | 62.5 | 8
20000 | 7.9 | 71.6 | 9.4 | 71.6 | 11.5 | 75.5 | 8
25000 | 9.4 | 84.6 | 11.1 | 84.6 | 13.6 | 89.3 | 10
31500 | 11.1 | 100.8 | 13.1 | 100.8 | 16.2 | 106.4 | 10
Data Sheet — OLTC variants (selected rows)Rated capacity (kVA) | Level I No-Load Loss (kW) | Level I Load Loss (75°C) (kW) | Level II No-Load Loss (kW) | Level II Load Loss (75°C) (kW) | Level III No-Load Loss (kW) | Level III Load Loss (75°C) (kW) | Short circuit impedance (%)
3150 | 1.8 | 22.2 | 2.1 | 22.2 | 2.6 | 23.5 | 7
4000 | 2.1 | 26.2 | 2.5 | 26.2 | 3.1 | 27.6 | 7
5000 | 2.6 | 30.8 | 3.0 | 30.8 | 3.7 | 32.5 | 7
6300 | 3.1 | 33.0 | 3.7 | 33.0 | 4.5 | 34.9 | 7.5
8000 | 4.3 | 36.5 | 5.1 | 36.5 | 6.3 | 38.6 | 7.5
10000 | 5.1 | 43.2 | 6.0 | 43.2 | 7.4 | 45.6 | 7.5
12500 | 6.0 | 51.1 | 7.1 | 51.1 | 8.7 | 54.0 | 8
16000 | 7.2 | 63.3 | 8.5 | 63.3 | 10.5 | 66.8 | 8
20000 | 8.5 | 74.4 | 10.1 | 74.4 | 12.4 | 78.6 | 8
25000 | 10.1 | 88.0 | 11.9 | 88.0 | 14.6 | 92.9 | 10
31500 | 12.0 | 104.4 | 14.2 | 104.4 | 17.4 | 110.2 | 10
Data Sheet (10 kV example - selected capacities)Rated kVA 30: No-load loss (steel) 65 W, Load loss (steel) 455 W, No-load loss (amorphous) 25 W, Load loss (amorphous) 510 W, Short circuit impedance 4.0%
Rated kVA 50: No-load loss (steel) 80 W, Load loss (steel) 655 W, No-load loss (amorphous) 35 W, Load loss (amorphous) 735 W, Short circuit impedance 4.0%
Rated kVA 100: No-load loss (steel) 120 W, Load loss (steel) 1140 W, No-load loss (amorphous) 60 W, Load loss (amorphous) 1270 W, Short circuit impedance 4.0%
Rated kVA 315: No-load loss (steel) 270 W, Load loss (steel) 2760 W, No-load loss (amorphous) 135 W, Load loss (amorphous) 3100 W, Short circuit impedance 4.0%
Technical specifications- Rated voltage: ≤ 35 kV.
- Rated capacity: typical 630–3150 kVA (ranges and exact loss/impedance values detailed in data sheets up to 31,500 kVA).
- Frequency: 50/60 Hz.
- Cooling: ONAN, ONAF, oil-immersed water cooling, forced oil circulation.
- Insulation: oil-impregnated insulation; option for amorphous core to reduce no-load losses.
- Protection & maintenance: gas relay, conservator, explosion-proof valve, oil sampling/drain facilities.
NoteTables present standardized no-load losses, load losses at 75°C and short-circuit impedance for multiple capacities and three efficiency levels; exact values, dimensions and masses depend on selected capacity, core material and cooling/OLTC configuration and are provided in the full product data sheets.