- Electricity - Electronics >
- Electronic Component >
- Electronic filter >
- SCHAFFNER
SCHAFFNER electronic filters
Frequency: 5 Hz - 150 Hz
Voltage: 0 V - 500 V
Primary current: 110 A
... Optimized drive efficiency Major reduction of leakage currents Elimination of bearing currents Applications Sine filter for the suppression of differential mode interference and common mode interference.
Block Transformatoren-Elektronik
Frequency: 100 MHz
Voltage: 50, 60 V
Primary current: 90 mA - 2,000 mA
Current compensated data line filter High common mode noise suppression at high frequencies Small influence on high speed signals through winding symmetry Climatic category 40/105/21 (Size 0603) Climatic category ...
Würth Elektronik eiSos
Frequency: 50 Hz - 60 Hz
Voltage: 380 V - 480 V
Primary current: 190, 250, 310, 400 A
The flexible filter for central/decentral harmonic mitigation The VLT® Advanced Active Filter AAF 006 improves system efficiency and increases grid robustness to avoid downtime. It can compensate for ...
Danfoss VLT Drives
Frequency: 4 kHz
Voltage: 200 V - 690 V
Primary current: 12 A - 1,500 A
DU/dt filters are used for filtering voltage increase rate and voltage peak value in motor input. With Trafox DU/dt filters, lengths up to 100–300 m can be reached, facilitating even ...
Frequency: 1.5 kHz - 4 kHz
Voltage: 380 V - 500 V
Primary current: 10 A - 460 A
The Sine filters are used for filtering high frequency interference in the input voltage of a motor in order to achieve cleaner sinusoidal voltage. High frequency interference is a great risk for motor ...
Frequency: 500 kHz
Voltage: 70, 40 V
Primary current: 10, 20 A
SynQor provides EMI filters for the Hi-Rel series DC-DC converters. All EMI filters provide >50dB or >80dB differential mode attenuation (model dependent) and >60dB common mode attenuation and include ...
SYNQOR
Frequency: 500 Hz
Voltage: 400, 500 V
Primary current: 3, 2, 1 A
SynQor provides EMI filters for the Hi-Rel series DC-DC converters. All EMI filters provide >50dB or >80dB differential mode attenuation (model dependent) and >60dB common mode attenuation and include ...
SYNQOR
Frequency: 250, 500 kHz
Voltage: 40 V - 210 V
Primary current: 70, 10, 40, 30 A
SynQor provides and DC-DC EMI filters for the Mil-COTS series converters. All EMI filters provide differential mode attenuation and common mode attenuation (model dependent) and include stabilizing bulk ...
SYNQOR
... Technologies FBAR (Film Bulk Acoustic Resonator) filters are a form of bulk acoustic wave (BAW) filter that have superior performance with steeper rejection curves compared to surface acoustic wave (SAW) ...
Frequency: 320 MHz - 2,500 MHz
... example in cordless telephones and mobile transceivers there is a need of high selectivity RF filter circuits. We have developed a series of helix filters providing an improved performance in such applications. At ...
Frequency: 915 MHz
Voltage: 5 V
SAW Filter SAW Filter, usually called SAW, makes use of the piezoeletricity effect, to convert the input signal into mechanical energy with input and output transducer. After a procedure of processing, ...
Frequency: 144 MHz - 470 MHz
... transmitter. Pass/reject filters are irreplaceable when the spacing between RX frequency and the interfering signal so small, that the slop of normal pass filters or reject filters are ...
CSTEL
Frequency: 144 MHz - 470 MHz
... narrow pass band. Filters allow to handle up to 200 watts power. There are one, two, or three cavities filters available. More cavities provide greater selectivity and, when required, a wider pass-band. ...
CSTEL
Frequency: 144 MHz - 470 MHz
... narrow pass or reject spacing. Filters allow to handle up to 200 watts power. There are single or dual cavity filters available. More cavities provide greater rejecting, when required, a wider notch. ...
CSTEL
The series of Harmonic filter reactors, which is manufactured by Entes, is device that is suitable for use in serial connection with capacitor banks in power factor correction components. By utilizing these kinds of reactors, ...
Frequency: 50, 60 Hz
Voltage: 120, 250 V
Primary current: 3, 6, 10 A
Features Single stage Chassis mounting High reliable High performance Fast on 6.3 x 0.8 mm terminals for input & output
Elcom
Frequency: 60, 50 Hz
Voltage: 208 V - 480 V
Primary current: 20, 320, 40 A
... Energy? • More than 20 years experience in active filtering solutions • Compliance to grid standards and norms • Integration of load balancing, power factor compensation and harmonics filtering ...
Frequency: 10.7 Hz
Murata’s ceramic filter series (CERAFIL®) offers small and lightweight filters and traps that use the piezoelectric properties of ceramics to treat intermediate frequencies used in AV and communication equipment.
Murata Electronics
Frequency: 60, 50 Hz
Voltage: 300, 520 V
Primary current: 3 A - 20 A
• Line filter as standard, industrial and medical version • 1 stage • Filter with standard or high attenuation (HP) Unique Selling Proposition • Compact single-stage filter • Various ...
SCHURTER
EMI filters are low-pass, band-pass, or high-pass filters combined with ESD protection diodes. They also integrate pull-up and/or pull-down resistors, depending on the application. ST EMI filters ...
... switched-capacitor filters (SCFs) operate from a single +5V (MAX7418–MAX7421) or +3V (MAX7422–MAX7425) supply. These devices draw only 3mA of supply current and allow corner frequencies from 1Hz to 45kHz, making them ...
ON Semiconductor offers LC, RC, and common mode filters for a wide variety of audio and data interfaces.
Frequency: 60, 50 Hz
Voltage: 380 V
Primary current: 15 A - 300 A
Active power filter (APF:Active power filter) with parallel connected to the grid, through real-time detecting the load harmonic and reactive component and the PWM converter technology, and harmonic and ...
Frequency: 50, 60 Hz
Voltage: 208 V - 690 V
Primary current: 50 A - 450 A
Overview Active Power Filter (APF) is a new type electronic device which is used to prevent dynamic harmonic and compensate reactive power. It can compensate the size-changing and frequency-changing ...
Frequency: 100 MHz - 156 MHz
HK-VSOF01 VHF single cavity band-pass filter applies to building civil aviation communication system. It can improve the selectivity of receivers. When multiple transmitters share one antenna, it can help improve the ...
Zhengzhou Huahang Technology Co.,Ltd.
... electromagnetic wave signal, filtering useless signals, reducing mutual disturbance between communication systems. Features: The prevision of product is high and the surface quality is good. When the low pass filter ...
Frequency: 2.4, 1.6, 5 GHz
LTCC filters are multi-layer ceramic devices that integrate several inductors and capacitors for signal processing. Obtainable in compact sizes, the filters offer superior performance over discrete ...
Yageo
The ZFM32H/300 is a high quality installation filter specifically created for eliminating adamant noises particularly LF and HF. It also gives a spike-proof functionality to avoid harsh elements to deeply penetrate and ...
Frequency: 50, 60 Hz
Voltage: 400, 690 V
Primary current: 200 A
Active Power Filter (APF): Model Number: APF 3P3W 50A – 200A, APF 3P4W 50A – 200A Nominal Capacity: 50 A – 200A Nominal Voltage: 220VAC, 400VAC, 690VAC Nominal Frequency: 50HZ/60HZ Installation method: Stand, Wall Mount ...
Shenzhen Consnant Technology Co., Ltd.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining