Sabre Tubular Structures offers a light duty line of standard class poles designed per RUS standard pole requirements. These poles satisfy the needs of both the cooperatives, governed by these requirements, and other utilities specifying a %u201Cwood pole equivalent%u201D type structure. Concerns regarding severe weather, woodpecker damage, accessibility issues in remote areas and simple environmental issues have increased the need to replace wood poles with steel pole structures. Sabre Tubular Structures' standard class poles are the perfect answer to those concerns. Call us today for your next standard class pole project.
Sabre Tubular Structures also provides customers with an interactive MS Excel based worksheet that allows the user to input basic design criteria, such as required height and embedment depth, and then creates the design calculation output for each pole class ranging from Class 3 to Class H9. In addition, input fields for fixity point below ground and "near pole top" allow users the ability to review the diameter and moment capacity at each location to determine the pole class best suited to their needs.
|
|
Conventional AC test transformers are especially designed for testing objects of medium capacitance. These systems are particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (inductive voltage transformers).
The possibility of stacking several of these transformer modules allows reaching very high voltage levels by keeping reasonable floor space.
|
|
Cast Resin Transformer
Catalog
For the demand of safety for the power distribution equipment, dry type transformers with fire resistant, non-polluting and humidity resistant features are often the right choice. AEC cast resin transformer will provide the best and safest service to all kinds of power distribution system application.
|
|
Transformers
Available in a variety of voltages. In-house production to meet custom requirements. Transformers for many voltage requirements are available directly from stock. A number of them are also available for hire.
Covering the medium and low voltage range
Any output and cooling system
Wide range of custom equipment
Hire equipment
Interim solutions to bridge downtimes
Equipment for experimental setups
|
|
160kVA to 15 MVA dry type cast resin transformers, up to 36kV
Description
IEC 60076-1 to 5 and 60076-11 Standards
Main characteristics:
. Phase to phase secondary voltage (V):400 to 433
. Phase to neutral secondary voltage (V):231 to 250
. Short circuit and lightning impulse withstand up to 250kV
|
|
Cast resin distribution transformers: Power ratings from 100 kVAto 10,000 kVA/36 kV
An alternative option to liquid-filled distribution transformers with the emphasis on reduced environmental impact and increased fire safety.
Cast resin distribution transformers are manufactured in Mechelen (Pauwels Trafo Belgium N.V)
|
|
Fire resistant Cast resin transformers are well suited for installation in high-rise buildings, hospitals, underground tunnels, school, steel factories, chemical plants and places where fire safety is a great concern. Hazard free to the environment, cast resin transformers have over the years proven to be highly reliable.
Our Transformer Range :
- Distribution range from 50kVA to 3000kVA
- Power range from 3000kVA to 16MVA
- Primary voltages up to 36KV
Basic Features :
- Free standing cast resin transformer complete with bi-directional rollers
- Set of PT100 Ohm
- Naturally ventilated steel enclosure (IP21)
- Bottom entry gland plates for HV & LV terminations
- Naturally cooled (AN)
- Tap changer (Manual links)
- Rating plate
- Lifting points
- Earthing point
- Compliant to IEC 726
|
|
|
The LS Industrial Systems' CAST RESIN Transformer has succeeded in combining the advantage of oil-filled and conventional dry type transformers, which are fabricated with an epoxy resin. The windings are completely embeded under vacuum conditions.
|
|
Salisbury offers a complete line of SALVAR® Composite Insulators. For decades, thousands of Salisbury SALVAR insulators have been installed by utilities worldwide in a variety of environments.
Unibody or Modular design
SALCOR EPDM and Silicone weathersheds
Unibody style Dead End/Suspension insulators, 15kV to 46kV
Modular style insulators, 35kV to 138kV
Tongue & Clevis, Ball & Socket, Ball & Eye,
Eye & Eye, End Fittings
Also available:
- Line Spacers - 15kV to 46 kV
- Line Post Insulators - 15kV to 69kV
- Horizontal and Vertical Mounting; stud base and gain base styles
|
|
|
Trading under the names Raychem, Axicom, Morlynn, Dulmison and Zibo, Tyco Electronics Energy Division offers a comprehensive range of porcelain, polymeric and hybrid solutions for the electricity supply industry. Experience in the design and manufacture of insulators exceeds 80 for porcelain, 30 years for polymeric and 20 years for hybrid products. The manufacturing processes employ some of the most advanced technologies in the field of insulator production. A commitment to quality is evidenced by independent certification of quality systems complying with international standards.
|
|
Sabre Tubular Structures manufacturers a full line of transmission and distribution structures, including single poles, h-frames and 3-pole structures. With in-service projects ranging from a single pole location to 300 pole lines in heights of 60' through 220', Sabre has the staff and manufacturing capabilities to provide your next project.
Sabre can accommodate most types of foundation requirements including anchor based, direct embedment, and caissons. Although anchor bolt cages are typically designed to an optimum length based on pole design, Sabre can provide full length cages based on your foundation depth when needed. In addition, below grade protection coatings are applied in-house by Sabre personnel and certified by Madison Chemical, Inc.
|
|
|
|
|
|
DHSG-1 switchgear cabinet for twin drives with total load currents of up to 300A
The DHSG-1 flameproof switchgear unit was developed for coal-industry applications, but can also be used in other explosive mining atmospheres.
The DHSG-1’s extremely compact dimensions make it highly suitable for performing switching and control tasks on mobile mining machinery, such as loaders and drill jumbos, as well as for the protection of three-phase a.c. motors, transformers and lighting circuits.
The DHSG-1 switchgear unit offers the following advantages:
power-loss monitoring for overcurrent, short circuits and earth faults, including cold conductors
lighting output in the supply voltage with separate earth-fault monitoring
unit-running indicator in 42 V and 42 V output mode with earth-fault monitoring
intrinsically-safe controls with integral start-up warning and siren function
compact space-saving design.
The unit is designed for operating voltages of 500 V to 1000 V. Voltage switching is achieved by means of a simple plug changeover.
|
|
|
The stop switch is used to shut down the wind generator if it is not to be operated or to prevent starting of the rotor when working on it. Wiring the stop switch is not obligatory if a charge regulator has been installed.
|
|
This Outdoor high performance disconnectors are manufactured for high currents und difficult environmental conditions. That means high pollution degree up to PD4 and high operating cyles.
Tecnical data up to 38.5 kV, 4000 A, 31.5 kA.
Special field of applications are electic power transformation substations, steel- or mine mills.
All switches can be equipt with manual- or motor actuator, automatical earthing device and auxiliary contacts.
|
|
|
Using its knowledge and experience in the field of material design, Raychem has pioneered some of the most important technical advances in cable accessory technology. Heat-shrinkable accessories are well accepted for medium-voltage distribution by utilities, equipment manufacturers and industrial users throughout the world. For fifteen years, accessories have also been available for 69kV, 72kV, 84kV transmission-voltages. For higher voltage classes we offer 145kV to 170kV prefabricated joints and terminations for indoor and outdoor switchgear and transformers
|
|
|
High-voltage power capacitors are designed for reactive power compensation of electrical networks and industrial plants.
|
|
Power capacitors for cos phi (?) correction and for High Voltage Harmonic filtering, are produced in accordance to international standard IEC 871, with container/box of stainless steel and porcelain bushings.
Basically it exists two kinds, depending on the connection that we are going to carry out.
Single phase (1 or 2 bushings) with internal fuses.
3 phases (3 bushings) with internal fuses for direct connexion to the network.
|
|
Lifasa HV capacitor banks either fixed or automatic have the necessary elements for its assembling and adjustment for an optimal service and work of the capacitors in the network.
The election of the equipment, as well as its configuration and setting up, will depend on the network voltage, as well as the consumption of the loads in the installation.
|
|
Nominal voltage Un: from 10kV to 50kV 50/60 Hz
Capacitance: from 20nF to 200nF
Test voltage: up to 100kV 50Hz / 200kV DC
|
|
|
These power factor correction equipments are open-rack type and are for outdoor installations, where large blocks of three phase kVAR are required. Racks are shipped ready for field installation with base and inter-rack insulators, 8 foot substructure, interconnecting bus wire and other accessories for a three-phase equipment.
|
|
Features :MKP1840M: Miniaturized Metallized Polypropylene Film Capacitor
- Miniaturized with extensive voltage, pitch and capacitance ranges
- Voltage range: from 250 to 2000 VDC
- Pitch range: from 5 to 37.5 mm
- Capacitance range: from 0.001 to 6.8 µF
- RoHS-compliant
- AC and Pulse applications include: high frequency and pulse operations.
|
|
Capacitor banks Energy
Description
Medium voltage capacitor banks Energy are designed for power factor correction in electrical networks from 15 to 36kV. Global compensation offer from 600 kvar to 5 Mvar is composed of:
CP227 fixed capacitor banks
CP254 automatic capacitor banks
Technical data:
indoor installation
altitude less than 1000m
protection degree of the enclosure IP23
insulation voltage (kV):17.5, 24, 36
rated voltage (V):15000, 22000, 33000
|
|
|
|
|
|
With the CT contactor series Schaltbau is introducing a new and innovative contactor concept to the market: power contactors in a completely new style and design, specially developed for the sophisticated requirements of the railway industry. The outstanding technical feature of this new product is the innovative combination of electromagnetic and permanent-magnetic blowout technology for electric arc control. The successful combination of these two principles greatly improves both switching functionality and reliability and forms a practical and economically impressive device concept.
The innovative core of the new CT series is the electric arc control technology: in contrast to contactor concepts purely based on electromagnetic blowout, the arcs created at the moment of switching off are ignited in powerful permanent-magnetic blowout fields. Thus the dwell periods in the contact zones are limited to an absolute minimum. This leads to a significant reduction in arc-related burn-up when switching off. The lower degree of wear on the contacts makes it possible to greatly increase maintenance intervals.
The arcs blown out of the contact zones act as wear-free switches in the next phase: the skipping to adjacent arc modulators activates the blowout coils, making switching-off procedures independent of the direction of the current from that moment onwards. In the final phase the arcs pass through an arc chute, are stretched across the divergently arranged modulators and then effectively extinguished in a ceramic chamber. The special design of the extinguishing process reduces the discharge of ionised gases from the arc chute.
|
|
|
|
|
|
Over the past century, GE has designed and manufactured literally tens of thousands of medium and high voltage circuit breakers. Although many of the older designs are no longer manufactured, many units remain in service. GE can deliver solutions for these breakers without the cost and downtime associated with complete equipment replacement. If you have any of the following breakers in service, we can provide parts or engineered solutions to support your maintenance needs:
Features and Benefits
* Parts designed and manufactured to the original or improved specifications.
* Parts in stock for fast delivery when you need them.
* Engineering support to provide support for your specific requirements.
* Extend the service life of your equipment with Genuine GE Parts, designed by the original manufacturer assuring reliable fit and performance.
* Increase rating capacity with packaged engineered solutions.
* Save time with easy to install original parts
* On-site service installation or supervision optionally available.
|
|
|
|
|
|
Gerapid high speed DC circuit breakers are single-pole circuit breakers designed for use in high energy, high reliability DC power distribution systems. They are suitable for protection of mains and semiconductors (converters/rectifiers) in railway and industrial applications. Feeder circuit breakers and rectifier circuit breakers are available with operating currents up to 8,000ADC and operating voltages up to 3600VDC. They have a very high interruption capacity combined with a current limiting characteristic.
Innovative materials, superior circuit breaking capacity and outstanding dielectric performance ensure service continuity and protection during adverse system events. The technology and quality of these circuit breakers produce high reliability, extended maintenance intervals and uncomplicated serviceability for all fixed installations
Features and Benefits
- Ratings up to 8000A and 4000 Vdc (3,600 Vdc, ANSI)
- IEC 947-2, EN50123-2, and ANSI C37.14 Certifications
- Solenoid drive (integral control unit, mechanically latched, no auxiliary power required to keep contacts closed)
- Available electrodynamic release for very high speed switching
- Two Stage contact system extends life of main contacts
- Compact, enclosed construction
- Full range of accessories, including up to 10 auxiliary contacts
Applications
- Traction power (light rail transit, tram, subway, maglev, etc.)
- Industrial plant protection (electrolysis plants, iron and steel mills, etc.)
- Mining
- Chemical, petrochemical
- Power generation
- Research/experimental (e.g., physics, particle accelerator protection)
|
|
Features and Benefits :
- Parts designed and manufactured to the original or improved specifications.
- Parts in stock for fast delivery when you need them.
- Engineering support to provide support for your specific requirements.
- Extend the service life of your equipment with Genuine GE Parts, designed by the original manufacturer assuring reliable fit and performance.
- Increase rating capacity with packaged engineered solutions.
- Save time with easy to install original parts
- On-site service installation or supervision optionally available.
Product Scope:
- MagneBlast Medium Voltage vertical lift circuit breakers.
- FK, FKD, FKA and VIB medium and high voltage outdoor distribution breakers.
- ARA generator breakers.
- ATB high Voltage transmission breakers.
- Type MC and AG dc breakers.
|
|
Siemens high-voltage circuit-breakers offer the optimum technical and economical solution for every requirement. Depending on the application and the voltage level, they are equipped with the following combinations of arc quenching principle and operating mechanism:
* Self-compression principle with stored energy spring mechanism
* Puffertype with hydraulic mechanism
All the live- and dead-tank circuit-breakers, as well as the gas-insulated switchgear (GIS), are equipped with the same components. Longevity, reliability and highest availability in all climate zones in the world distinguish Siemens high-voltage circuit-breakers from all others.
|
|
|
|
|
|
TAG200 - Electronic voltage absence detector HTA
The TAG200 is an electronic voltage detector designed to check the voltage presence or absence on HTA installations. It is in compliance with the NF C 18-311 standard.
This simple, sturdy appliance is used throughout the world on HTA networks and installations, particular on those of EDF.
TAG2000 - High Voltage Detector HTA
The TAG2000 is an electronic voltage detector which is in compliance with the standards which are applicable and compulsory for all operations used to check for voltage presence or absence.
This appliance is highly stable when operating, whatever the network configurations and the operating temperatures.
Exclusively, this appliance can be set with 3 distinct and self-commutating voltage ranges. This appliance is used on the HTA EDF network.
TAG330 - High Voltage Detector HTB
The TAG330 is an electronic detector used to detect HTB voltage absence up to 735kV. It is fitted with electronics integrating miniature gas-filled spark gaps. Its performance is very high, particularly in the case of very high induction and/or parasite high frequency electrical fields.
|
|
275HVD Non-Contact Voltage Detectors
The Model 275HVD is designed to detect the presence of high voltage without physical contact.
An eight position rotary switch selects the detection range. As the sensor is moved closer to the voltage carrying conductor, its sensor head picks up the radiated electric field. Once the threshold is reached, the buzzer sounds and a bright red warning light warns the operator of live conductors.
The Model 275HVD is powered by three standard Alkaline C cell batteries and can be used both in- and out-of-doors. A universal spline on the back-end facilitates attachment to any standard hot stick. A self-test position ensures that all circuitry and annunciators are working properly before use.
|
|
PHE III Voltage Detector
* Also for use in wet weather
* For indoor and outdoor installations
* With self-testing element
* Visual and acoustic indicator
* Wide nominal voltage ranges
* Easy transport due to detachable insulating rod and test prod
* Fast battery replacement without tools
* Test set with interchangeable test prods for switchgear installations and overhead lines
Nominal voltages up to 30 kV / 50 Hz
|
|
|
|