A range from 0.05 to 250 m water
These sensors are used to measure liquid levels for applications such as:
- filling tanks
- check of water table levels
Our sensors can be equipped with configurable recording systems. Their very low power consumption design enables several years autonomy.
Their internal memory allowe to record 500 000 values. |
|
Extremely short microwave impulses with low emitted power in the C-band and K-band frequency range are emitted by the antenna system to the measured product, reflected by the product surface and received again by the antenna system. They spread with light velocity and the time from the emission to receipt of the signals is proportional to the level in the vessel. A special time spreading procedure enables a reliable and precise measurement of extremely short time periods.
By simply entering the vessel dimensions, a level-proportional signal can be displayed. An adjustment with emptied and filled vessel is no longer necessary!
The spreading of microwaves is virtually not affected by the ambient temperature and ambient pressure. Radar sensors are ideal for use under arduous process conditions. Pressures from vacuum to 160 bar and temperatures between -40 and 400°C are no problem for a radar level measurement.
Fluctuating product compositions or complete changes of the product do not influence the measurement result. A new adjustment is not necessary. |
|
For measuring ranges up to 70 m, VEGA now has an optimised radar technology in its program. Due to its increased receiver sensitivity (factor 40), VEGAPULS 68 delivers reliable measured values in spite of higher signal damping in solids.
Non-contacting radar measurement delivers reliable levels in dusty environments, like in storage facilities for building materials. Also in the food processing industry, in steel production as well as for level measurement of powders and granulates in the chemical industry, the extended measuring range has proven to be extremely effective. Adjustable fl anges allow the eduction of false refl ections and the optimisation of the useful echo.
All advantages in an overview
- non-contact measurement
- unaffected by dust generation
- not infl uenced by fi lling noise
- high dynamic range of the sensor
- measuring range up to 70 m
- antenna cleaning by cooling air
- dust-Ex approval |
|
| The Barksdale Tank Level Indicating Systems are sensors for remote indication level of liquid media. They operate according to the float principle with magnetic trans-mission (Permanent magnet, Reed switch and resistor chain). The liquid level is indicated on indicating instruments connected to the sensor. |
|
Sensortechnics is a leading manufacturer and distributor of a wide range of sensors and fluid control devices. The product portfolio includes basic pressure sensors, rugged transmitters, submersible level sensors and customised pressure sensing systems from 1 mbar up to 1000 bar as well as liquid level switches, oxygen, flow and force sensors. Additionally, Sensortechnics offers ultrasonic air bubble, air-in-line, liquid level and fluid monitoring sensors and detectors. Fluid control devices include miniature solenoid valves and diaphragm pumps, electronic pressure controllers and custom specific fluidic control systems.
Sensortechnics has more than two decades of experience in providing highly customised sensing products and in the development of complex integrated fluid control systems for OEM customers worldwide. |
|
Ultrasound level sensor SIMATIC PXS
Recording of fill levels from a distance of 3 cm to 10 m
Our sonar proximity switches sense objects of varying materials, shapes, colors or consistencies with absolute precision, flexibility and reliability.
The ultrasound level sensor is proper for level applications in containers due to its design and its technical constructions. The devices feature two switching outputs to which different distances can be assigned. This allows, for example, the minimum and maximum fill level in a tank to be evaluated. Regardless whether the objects are liquid, solid, powdery or even transparent. |
|
Short ultrasonic pulses between 10 kHz and 70 kHz are emitted by the transducer. These pulses are reflected by the product surface and received again by the transducer. They spread with sound velocity and the time from emission to receipt of the signals is proportional to the level in the vessel.
Latest microprocessor technology and proven ECHOFOX® software select the level echo from a number of false reflections and measure it exactly.
Just by entering the vessel dimensions, a level-proportional signal can be displayed. An adjustment with emptied and filled vessel is no longer necessary!
Thanks to different emitting frequencies, levels can be detected in a measuring range between 4 m and 70 m. Optional swivelling holders enable an ideal positioning of the sensors in the solid area.
Fluctuations of the product compositions or complete product changes do not influence the measurement results. A new adjustment is not necessary.
Advantages
- Non-contact
- Independent of product characteristics
Applications
- Level measurement of solids and liquids
- Good chemical resistance |
|
OptiLevel is the leading edge system for liquid level measurement in smaller storage tanks. The OptiLevel tank gauging system is the best choice for your above and underground storage facilities.
The OptiLevel tank gauging system can be used for all applications in petroleum and petrochemical installations.
The state of the art HLS 3010HF level sensor and designed system architecture enable open interfacing to the Entis Inventory systems and other protocols. |
|
Limit switch made of plastic for liquids and bulk goods
CPS 01
Features:
Quick and easy setting via programming by keystroke
Electrical connection: Cable or plug M8
PNP transistor output Housing made of PP or PVDF
Make contact or break contact
Outstanding price-performance ratio
Functional LED display Small and compact
Thread BSP G½"
Description:
Immersing the CPS 01 into the medium will cause a change in capacitance in the electrical capacitor. The change in capacitance is detected by the electronics and the switching operation is initiated.
Adjustment to the corresponding medium is carried out with the help of a programming key (programming via keystroke).
Application:
Designed for level limit detection of liquids and powdery or fine-grained bulk goods. |
|
Fully insulated, capacitive rod electrode for level measurement
For use in conductive liquids
All advantages in an overview:
- robust and maintenance-free
- easy installation and mounting
- measurement along the complete probe length
- insulation thickness 2 mm
- instrument from the plics® family
Version rod: - fully insulated
Insulation: PE, PTFE
Length: 0.1 ... 6 m
Process fitting: thread from G¾A
Process temperature: -50 ... +200 °C
Process pressure: -1 ... +64 bar (-100 ... +6400 kPa) |
|
Mounting [flush / nonflush] [ B / NB ] NB
Operating distance Sn [mm] 1... 8
Hysteresis H [%SR] 15
Frequency of operating cycles f [Hz] 100
Repeat accuracy R [%SR] 2
Operating temperature range Ta [C°] -30... 60
Temperature drift [range] [%SR] 15 [ -5... 55]
Protection class IP 65
Rated insulation voltage Ui [V] 75 d. c.
Material of housing A. PVC; B: PVC; C: PVC
Utilisation category DC13
Connection 2m / 3x 0,14mm2 PUR |
|
Level measurement instrument in stainless steel 1.4571
with integrated temperature sensor
TN 210
Characteristics:
Analog level signal 4-20 mA, two-wire transmitter
Max. 4 level switches (bistable) pnp-output. Control elements: reed contacts or magnet sensors
Analog temperature signal 4-20 mA, two-wire transmitter
Temperature switches: pnp-output or thermostat for switch action
Advantages:
Reductions of costs: max. 4 different measurements in one measuring instrument
Economy of time, of storage costs, of assembly costs etc.
Areas of application:
IMB combined measuring instruments are suitable even for rough environments and are applicable in the following industries:
plant engineering, off-shore, machine construction, power plants, chemical industrie, ship-building, biochemical industrie, food industrie, petrochemical industrie, pharmaceutics etc. |
|
Level sensor acc. to the measuring principle of the guided microwave (TDR)
For universal use in heavy solids and liquids
All advantages in an overview
- setup without adjustment
- independent of product features
- insensitive to dust, vapour and buildup
- probe can be shortened
- signal processing ECHOFOX for echo analysis with Fuzzy-Logic
Version: with exchangeable cable (ø 6 mm) or rod (ø 16 mm)
Measuring range cable: up to 60 m; rod: up to 6 m
Process fitting: from G1½A
Process temperature: -40 ... +150 °C
Process pressure: -1 ... +40 bar (-100 ... +4000 kPa)
Accuracy: ±5 mm |
|
External display and adjustment unit
Suitable for external display of measured values and adjustment of the sensors
All advantages in an overview:
- digital and quasi-analogue display of measured values
- can be mounted up to 25 m away from the sensor
- inclusive PLICSCOM
- instrument from the plics® family |
|
With our new Laser-Distance Sensors DLS-B you measure absolute distances up to 500 meters. Thanks to state of the art laser technology the DLS-B device measures with a precision of 1.5 millimeters. It represents a cost efficient solution even at extreme environment temperatures as low as -40° C.
The DLS-B is an optical measuring device. You can measure, maintenance-free, distances on natural and reflective surfaces. You determine positions on objects difficult to access or with very high surface temperatures. Just as well you can measure distances in an aggressive environment in an easy and accurate way.
Serial, analog and digital interfaces are standard features for the complete DLS-B product line. This enables you to easily connect the DLS-B to a control system (SPS, IPC or PC)
The DLS-B device runs in a “Stand-alone-mode” and independently executes all programmed functions. Thanks to the flexible range of functions an external display can be connected directly to the DLS-B device via interface RS232 or RS422. Via a digital input, measurements can also be activated from an external button or switch.
For easy configuration of the DLS-B devices, the necessary software is at your disposal |
|
Continuous level sensors designed with potentiometric output signal, 3 adjustable alarms or 4/20mA converter. Brass stem and NBR float or stainless steel AISI 316 executions. Contact distance 10 or 15 mm. G1 1/4" - G2" thread connection of Ø52 - Ø92 flange in aluminium or stanless steel.
Executions approved for hazardous areas (EX zones) are also available. |
|
LIDEC level switches: a dependable solution for liquids detection
Developed in cooperation with “Paris VI” University, the Lidec series liquid level sensors series are especially designed for marine applications.
They provide a reliable solution to liquid level detection.
Their operating principle, a patent granted to Enraf Marine Systems, is based on the propagation of a surface wave inside a stainless steel probe.
This principle is fully static, without vibration or moving parts. A "self-monitoring" function ensures the reliability of this equipment. This allows these sensors to be used in safety systems such as overfill protection, bilge well alarm and water ingress detection... |
|
Special features:
Reliability
Robust construction with magnetic transmission of measured values.
Wide and clear scale.
Can be used in hazardous areas (Zone 0).
Technical data:
Range: up to 6 m
Connection: up to DN100 / ANSI 4"
Nominal pressure: up to PN 320
Process temperature: -50°C ... +260°C
|
|
Continued investment in research and development allows the introduction of new products which are future-orientated and can be readily integrated into the new automation systems of today.
Since 1953, Endress+Hauser has manufactured level measurement instruments for industry and has developed and optimised a wide range of measuring techniques. Today, a wide range of designs and process connections are available accompanied by application-specific interfaces. All instruments have been extensively tested and certified. |
|
Level sensor acc. to the measuring principle of the guided microwave (TDR)
For universal use in light solids and liquids
All advantages in an overview
- setup without adjustment
- independent of product features
- insensitive to dust, vapour and buildup
- probes can be shortened
- signal processing ECHOFOX for echo analysis with Fuzzy-Logic
- instrument from the plics® family
Version with exchangeable cable (ø 4 mm) or rod (ø 6 mm)
Measuring range cable: up to 32 m
rod: up to 4 m
Process fitting from G¾A
Process temperature -40 ... +150 °C
Process pressure -1 ... 40 bar (-100 ... 4000 kPa)
Accuracy ±5 mm |
|
Measurement Principle:
A low energy pulse, generated by the Jupiter electronics, travels the length of the magnetostrictive wire. A return signal is generated from the precise location where the magnetic field of a float intersects the wire. A timer precisely measures the elapsed time between the generation of the pulse, and the return of the acoustic signal.
Features:
Precision level measurement ±0.015" (.381 mm)
Lengths to 400 inches (1016 cm)
Maximum process temperature:
Direct Insertion +500° F (260° C)
External Mount +850° F (+455° C)
Supports FDT/DTM standard, PACTware PC software
Applications:
Boilers (with magnetic level indicators)
Surge Tanks
Gas Chillers
Biotherapuetics
Pharmaceuticals
Process Vessels
Options:
Foundation fieldbus digital ouput
Hastelloy® or Monel® materials of construction
Threaded, flanged process connections or externally mounted
Interface measurement
SIL 2 compliant models |
|
Pulsarpoint 600 - non-invasive point level measurement :
The Pulsarpoint 600 is ideal for situations where it is undesirable or impossible to make an entry into a liquid storage vessel, yet for example a high level alarm is required. Simply fixing onto the outside of the vessel, the Pulsarpoint 600 operates as an acoustic monitor, ultrasonic soundwaves being transmitted through the wall of the tank to detect the presence or absence of liquid. |
|
Optoelectronic level sensor
The optoelectronic Senlux Besta level sensors are used for the level monitoring of liquids. Depending on the medium they can be installed as a position-insensitive system. |
|
The micro level in smart level
FSA-Technology have been adjusted in the factory for most applications.
With this setting, the smart level sensors are suitable for detecting water based media without any further adjustment. |
|
| WEKA tank level indicators are suitable not only for general liquid level measuring applications, but are also a cost-effective means of detecting interface levels between dissimilar liquids. These sensors are unaffected by temperature and pressure, and provide a stable and linear signal output, even with the existence of liquid agitation or the presence of a foam layer. Their ruggedness meets the requirements of the toughest operating conditions, including military applications. They are available in different configurations to so that an optimum solution can be offered for any level measuring range. With only one moving part, these sensors are simple, reliable, virtually maintenance-free, and easy to service, if such a need arises. WEKA has unique capabilities in precision fabrication of stainless steel and other specialized corrosion-resistant metals. This, together with our large selection of float designs, allows us to offer level measuring solutions precisely tailored to your needs. |
|
| Pulsar's innovative dB range of transducers has taken ultrasonic level measurement into a new era. Unlike the high voltage, frequency dependent transducers of other manufacturers, which require special, protected interconnect cables, or low powered transducers built with intrinsic safety rather than performance in mind, the dB series combines low electrical power that meets intrinsic safety requirements with extraordinary high sonic power to give range and performance. |
|
Ultrasonic sensor for continuous level measurement
Especially suitable for measurement of solids with optional swivelling holder for optimum adaptation to the vessel geometry and material cone
All advantages in an overview:
- transducer of PA with stainless steel diaphragm (316L) and integrated temperature sensor for correction of the running time
- sensor in compact version or with separate transducer
- accuracy ±10 mm
- ECHOFOX signal processing with Fuzzy-Logic
- adjustment with PLICSCOM, HART handheld or PC
- instrument from the plics® family
Measuring range: liquids 1 ... 25 m; solids: 1 ... 15 m
Process fitting: flange with optional swivelling holder
Process temperature: -40 ... +80 °C
Process pressure: -0,2 ... +0,5 bar (-20 ... +50 kPa) |
|
KONTINUIELICHE LEVEL MEASUREMENT
- capacitive level probes for liquids and bulks in
High-grade steel or plastic one, exit 4-20mA, for vertical installation, for
aggressive media, remarks with removable head and
exchangeable or shortenable probe staff
- Niveausonden with float principle, for liquids, exit 4-20mA
or resistance signal, Kundensprezifi remarks, in high-grade steel
or plastic ones
Level border conditions: Capacitive contactors,
optical contactors,
Float switch |
|
|