Pressure: 300 psi
Temperature: 32 °F - 230 °F
The Clippard Pilot-Operated Check Valve works as a standard check valve, but can also be opened with an air pilot ...
Pressure: 0.5 bar - 10 bar
Temperature: -10 °C - 60 °C
Flow rate: 200 l/min - 1,400 l/min
Stop valve with manual override option. • Valve function: piloted non-return function • Screw-in with external thread • Pneumatically piloted • Pilot air ...
DN: 6 mm
Pressure: 315 bar
Temperature: -20 °C - 80 °C
Industrial hydraulic valve in a high performance range. Reliable throttling of the flow to setting value. Fine adjustment Direct actuated Setscrew with lock nut Connection diagram ...
Bosch Rexroth - Industrial Hydraulics
DN: 4 mm
Pressure: 0 bar - 320 bar
Temperature: -30 °C - 120 °C
Size 04 (D02) ● Qmax 20 l/min (5 GPM) ● pmax 320 bar (4600 PSI) Pilot to open check valve, poppet-type with subplate mounting interface acc. to ISO 4401, DIN 24340 (CETOP 02) ...
DN: 6 mm - 12 mm
Pressure: 10 bar
Temperature: -5 °C - 60 °C
Piloted non-return valves are designed to protect installations. When the compressed air supply is removed, the non-return valves will lock the air supply to the cylinder. ...
Pressure: 100,000 Pa - 700,000 Pa
Temperature: -5 °C - 60 °C
Flow rate: 3 l/min
Pilot Check Valve with State Detection • According to ISO 13849. • Solid state auto switch PNP: D-M9. • Lead wire connection : 500 mm and M8 connector. • Operating pressure range: ...
SMC
DN: 0.187 in - 1 in
Pressure: 3,000 psi - 8,000 psi
Temperature: 400 °F
... types of miniature check valves are available: Axial Flow Check Valves Side Exit Check Valves Zero Leak Check ...
DN: 0.25 in - 0.5 in
Pressure: 0 psi - 5,000 psi
Lee Pilot-Operated Cheks are pressure piloted to open check valves available in diameters from 0.250 to 0.500 of an inch. When pressure is applied to the pilot ...
DN: 0.375 in
Pressure: 5,000 psi
Flow rate: 0 us gal/min - 2 us gal/min
This high pressure, pilot operated check valve is only .375” in diameter and 2” in length. This valve acts like a normal check valve ...
DN: 0.25 in - 0.5 in
Pressure: 500 bar
Flow rate: 15, 55 l/min
C2.9511 Pilot-operated check valves C2.9511 Pilot-operated check valves without/with pre-release pipe-thread ...
DN: 5 mm - 9 mm
Pressure: 500 bar
Flow rate: 20, 50 l/min
C2.9512 Pilot-operated check valves C2.9512 Pilot-operated check valves without/with pre-release manifold-mounting ...
Pressure: 700 bar
Check valve, hydraulically pilot operated max. operating pressure 700 bar. Design: Housing made of steel, surface galvanized. Spring-loaded ball acting as a valve ...
Pressure: 0 bar - 1,706.4 bar
Temperature: 50 °C
Flow rate: 50 l/min
Temperature: 50 °C
Flow rate: 50 l/min
Temperature: 50 °C
Flow rate: 50 l/min
DN: 8 mm - 10 mm
Pressure: 350 bar - 500 bar
Temperature: -20 °C - 80 °C
... DERV pilot-operated check valves lock a cylinder in any rest position. They are intended for direct mounting in the cylinder. Advantages - Pilot-operated ...
BUCHER Hydraulics
DN: 3 mm - 6 mm
Pressure: 700 bar
Temperature: -40 °C - 80 °C
Our pilot-operated check valves are leak-proof check valves with which the flow direction from B to A is open and the flow direction ...
Pressure: 3 bar - 230 bar
Temperature: -30 °C - 80 °C
Flow rate: 14, 250 l/min
... from 3-230 bar – Completely sealed – For hydraulic and pneumatic and other fluides useable These pilot operated check valves are available ...
DN: 0.375 in
Pressure: 200 bar
Flow rate: 0 l/min - 20 l/min
The PKV-06 valve, made of stainless steel W.St.1.4301, allows unrestricted flow from V to C ports and blocks flows in the opposite direction until pressure is applied on the pilot port. PKV-06 is used ...
DN: 0.5 in
Pressure: 200 bar
... static load holder. Specifications The PKV-30 valve, made of stainless steel W.St.1.4301, allows unrestricted flow from V to C ports and blocks flows in the opposite direction until pressure is applied on the pilot ...
Pressure: 0 bar - 350 bar
This is a check valve (spring closing and cone on edge seals) with a built-in flow control feature. The mounting surface is according to the ISO 4401 standards. Its use allows: -prevention of flow one-way; -flow ...
Duplomatic Oleodinamica
... control valves These valves are designed to regulate the cylinder piston speed Check valves Full flow in one direction flow blocked in the opposite direction Pilot-operated ...
Pressure: 320 bar
Flow rate: 60 l/min
... description - Cetop 03 Non-return valve SMC SATURN - Specifications - Check valve with spring - Benefits - Locking function - Technical information - Minimum purity of the ...
Pressure: 2, 4 bar
Temperature: -15 °C - 70 °C
Flow rate: 35 l/min
Cetop 3 (NG6) Pilot Operated Check Valve – Pilot Operated Check Valves. Designed for use in applications requiring ...
YUKEN Europe Ltd.
Pressure: 3,000 psi
... long life. FREE FLOW IN ONE DIRECTION and checked flow in the other (Not a zero leak check). BUILT IN DAMPENING CHAMBER provides smooth action when pilot pressure is applied. HOLES DRILLED ...
Pressure: 10,000 psi
... use with open or tandem center valves. Permits free flow of fluid in one direction. Operation: Flow is blocked in opposite direction until pilot oil pressure is applied. This prevents the loss of pressure ...
... uncontrolled inflow of air into the exhaust gas system is avoided outside the operation of the secondary air system. The vacuum controlled check valve (ARV) is a pneumatically ...
DN: 0.25, 0.375, 0.5, 0.75 in
Pressure: 0 bar - 350 bar
Flow rate: 12, 30, 45, 85 l/min
This device from Dicsa has a steel body and a cracking pressure of 0,5 bar.
Dicsa
DN: 0.5 in - 40 in
Pressure: 0.4 bar - 20.7 bar
106 / 206-PR-C is used for pressure reducing and check valve which has 10 models. It has an excellent constant flow with drip-tight closing on the return flow and an isolation valve which ...
Pressure: 2 bar - 10 bar
Temperature: -20 °C - 150 °C
Flow rate: 170 l/min - 1,050 l/min
Pilot operated check valves allow, if mounted in pairs on the supply ports of a cylinder, to quickly block the movement of the rod in case of a sudden pressure drop. These one-way blocking ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining