- Metrology - Laboratory >
- Metrology and Test Equipment >
- Stability test chamber
Stability test chambers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Capacity: 108 l
Temperature: 0 °C - 70 °C
Length: 480 mm
Constant climate chamber HPP110eco Maximum energy efficiency in continuous operation - tailor-made for stability studies according to ICH guidelines, stability tests ...
Memmert GmbH + Co. KG
Capacity: 256 l
Temperature: 0 °C - 70 °C
Length: 800 mm
Constant climate chamber HPP260eco Maximum energy efficiency in continuous operation - tailor-made for stability studies according to ICH guidelines, stability tests ...
Memmert GmbH + Co. KG
Capacity: 384 l
Temperature: 0 °C - 70 °C
Length: 1,200 mm
Constant climate chamber HPP410eco Maximum energy efficiency in continuous operation - tailor-made for stability studies according to ICH guidelines, stability tests ...
Memmert GmbH + Co. KG
Capacity: 25 l - 2,300 l
Temperature: -25 °C - 70 °C
Length: 950 mm - 2,100 mm
... reproduction of more "extreme" tests, we mostly refer to an environmental chamber. FDM have been a leading company in temperature and humidity test chambers ...
Capacity: 8 m³ - 150 m³
... environmental rooms allow you to perform stability tests accurately and reliably, meaning you can test products in various environmental conditions whilst adhering to the numerous testing ...
Capacity: 250, 500 l
Temperature: 10 °C - 50 °C
Photostability test chambers in accordance with the ICH Q 1 B Guideline, Pharma-L The Pharma 250-L and Pharma 500-L photostability test cabinets of the weisstechnik® and vötschtechnik® ...
Temperature: 2 °C - 70 °C
Stability Test Chambers, Type Pharma The Pharma cabinets from weisstechnik® were specifically developed to meet the requirements of a test laboratory in pharmaceutics. ...
Temperature: -60 °C - 150 °C
Length: 850 mm
Width: 600 mm
... High temperature test method. IEC 68-2-3 Test CA: Constant damp heat test method. IEC 68-2-30 Test CB: Alternating damp heat test method. IEC 68-2-14 ...
Guangdong Bell Experiment Equipment Co., Ltd
Capacity: 80, 1,000, 800, 408, 150 l
Temperature: -70 °C - 150 °C
Length: 1,900, 1,650, 1,700 mm
environmental test chambers The environmental test chamber can also be called a constant humidity climate test chamber or stability ...
Guangdong Bell Experiment Equipment Co., Ltd
Temperature: -40 °C - 150 °C
Length: 1,950, 1,800 mm
Width: 1,300, 1,500 mm
High low environmental test chamber High and low temperature test chamber is suitable for high temperature and low temperature reliability tests of ...
Guangdong Bell Experiment Equipment Co., Ltd
Capacity: 600, 1,200 l
Temperature: -5 °C - 45 °C
Length: 2,090 mm
Designed for low humidity levels and temperature stability these chambers provide a perfect environment for testing under constant climatic conditions. Ideally suited for biological material storage, ...
Aralab
Capacity: 600, 1,200 l
Temperature: -5 °C - 60 °C
Length: 1,980 mm
600 and 1200 liters environmental chambers for Stability testing and controlled storage applications. Flexible interior allowing for different shelving configurations. Very precise and uniform stability ...
Aralab
Capacity: 29, 19, 32, 10 m³
Temperature: 15 °C - 45 °C
Length: 2,610 mm
... storing or testing under controlled climatic conditions. Aralab Stability ‘walk-in’ chambers for stability testing and controlled environment storage, offer an unsurpassed stability ...
Aralab
Temperature: 80 °C
Length: 114 cm
Width: 94, 700 cm
It is suitable for accelerated yellowing aging test of leather, textiles, plastics, rubber and paper materials. It can be used as a reference to determine the yellowing grade of materials, and can also be used to visually ...
Temperature: 121, 132, 143 °C
Length: 900 mm
Width: 900 mm
... generation product. 4. The cold air is exhausted before the test; the cold air exhaust design (the air in the test barrel is exhausted) during the test improves the pressure stability ...
Capacity: 416, 749, 240, 109 l
Temperature: 0 °C - 100 °C
Length: 1,600, 1,340, 1,850, 2,010 mm
CLIMATIC CHAMBERS WITH A STEAM HUMIDIFIER The KKS climatic chambers with steam humidifier do not emit ultrasounds and therefore allow insects breeding (e.g. Drosophila melanogaster). Compared to the ...
POL-EKO sp.k.
Capacity: 109 l - 1,485 l
Temperature: 0 °C - 60 °C
Length: 1,340 mm - 2,000 mm
... placed 25 cm below the lighting panel) CLIMATIC CHAMBERS WITH PHYTOTRON WITH OVERSHELF LIGHTING PANELS Phytotron chambers with in-door lighting are available in 3 sizes:115, 240 and 750. Climatic ...
POL-EKO sp.k.
Capacity: 749, 240, 109 l
Temperature: 0 °C - 60 °C
Length: 1,340, 1,600, 2,000 mm
... cm below the lighting panel) CLIMATIC CHAMBERS WITH PHYTOTRON WITH LIGHTING IN DOOR The most uniform illumination of the entire chamber, is possible when using lighting from three sides. Phytotron ...
POL-EKO sp.k.
Capacity: 1,200, 600, 250 l
Temperature: 10 °C - 50 °C
Length: 1,370 mm
... possible to adapt the chamber the chamber for the photostability test according with the directive: ICH Q1B Photostability Testing of New Drug Substances and Products, option 2. • ...
Capacity: 0 m³
... cabinet sunlight exposure is used to photo stability studies according to “ICH Q1B – Photo stability Testing of New Drug Substances and Products, option 2”. •Display of the inside temperature of the ...
Capacity: 500, 800, 1,000, 1,500 l
Temperature: 0 °C - 65 °C
Product features: ● Newly fluoride-free design, high efficiency, energy saving. ● Special sterilization stainless steel liner, semicircle design(Four corners), easy cleaning. ● Micro-computer controller, data digital display.(For SD/GSD ...
Sanwood Technology
Capacity: 2 m³ - 250 m³
Temperature: 0 °C - 65 °C
... Anti-lock system, can walk in and out freely. Execution and satisfying criteria: Supported by the 2015 Pharmacopoeia drug stability test guidelines and GB/T10586-2006 relevant terms. EU safety ...
Sanwood Technology
Capacity: 250, 400, 80, 150 l
Temperature: 0 °C - 65 °C
... sterilization system disinfect virus and prevent the chamber from being pollution. ◆Illumination automatically detect and control(Optional) ● Breakthrough the defect of domestic drug stability test ...
Sanwood Technology
Capacity: 350 l
Temperature: 4 °C - 60 °C
Width: 925 mm
Stability Chambers without humidity control - Horizontal Airflow FIELDS OF APPLICATION Laboratory testing Quality test Chemical industry Environmental test Food industry
FALC Instruments S.r.l.
Capacity: 500 l
Temperature: 4 °C - 60 °C
Width: 850 mm
Stability Chambers without humidity control - Horizontal Airflow FIELDS OF APPLICATION Laboratory testing Quality test Chemical industry Environmental test Food industry
FALC Instruments S.r.l.
Capacity: 700 l
Temperature: 4 °C - 60 °C
Width: 850 mm
Stability Chambers without humidity control - Horizontal Airflow FIELDS OF APPLICATION Laboratory testing Quality test Chemical industry Environmental test Food industry
FALC Instruments S.r.l.
Temperature: -55 °C - 180 °C
Climatic walk-in chambers are used to simulate specific climate and temperature environments required for stability testing, accelerated stress testing, and conditioning of inorganic materials, biomass, ...
Temperature: -70 °C - 180 °C
... humidity, vibration stress screening test, in order to assess product adaptability or experiment on behavior evaluation. Temperature Humidity Vibration Combined Chamber Features: 1. A combined structure ...
AI SI LI (China) Test Equipment Co., Ltd
Capacity: 8,000 l
Temperature: -80 °C - 180 °C
Length: 2,000 mm
... temperature humidity test Room Features: 1. Graceful appearance, circularly shaped body, surface treated with mist strips . Easy to operate, safe and reliable. 2. Rectangular double-paned viewing window for viewing ...
AI SI LI (China) Test Equipment Co., Ltd
Capacity: 6,000 l
Temperature: -60 °C - 150 °C
... temperature humidity test Room Features: 1. Graceful appearance, circularly shaped body, surface treated with mist strips . Easy to operate, safe and reliable. 2. Rectangular double-paned viewing window for viewing ...
AI SI LI (China) Test Equipment Co., Ltd
Capacity: 50 l - 500 l
Temperature: -65 °C - 180 °C
Length: 1,100 mm - 1,750 mm
Application Area 1. SONACME Two Zone Thermal Shock Test Chamber is ideal for testing IC Chips and small electronic products. 2. The design consists of two independently controlled chambers. ...
SONACME Technology
Capacity: 50 l - 500 l
Temperature: -55 °C - 150 °C
Length: 1,400 mm - 2,050 mm
Application Area 1. SONACME Thermal Shock Test Chamber Is Designed To Provide A Rapid Transition Between Hot And Cold Temperature Zones. Provide Vertical, Horizontal And Liquid Models. 2. Thermal Shock ...
SONACME Technology
... Acceelerated Aging Test Chamber is widely used in the sealing performance test of multilayer circuit boards, IC packages, LCD screens, LEDs, semiconductors, magnetic materials, NdFeB, ...
SONACME Technology
Capacity: 830, 1,300 l
Temperature: 25, 30, 40 °C
Length: 1,950, 1,993 mm
• Perfect tool for stability testingin pharmaceutical Industry • Following ICH guidelines • Calibrated at all ICH points • GMP Qualification package available • Two different volumes available Fully stainless-steel ...
Kambic d.o.o.
Capacity: 57, 125 l
Temperature: 8 °C - 55 °C
Length: 400, 500 mm
... Access for Cables & Probes Stable, silent, vibration free climatic conditions Keeping superior temperature & Rh stability Small product stability testing Cascade PID control
Kambic d.o.o.
Temperature: -60 °C - 150 °C
Walk in test chambers are used in electrical, electronics, aerospace, battery, and automotive fields. It can be used to test significant components and as a temperature or humidity chamber. ...
Temperature: 100 °C
... control system software at the same time Walk-in aging test room description: Walk-in aging test room is known as burn-in room or aging room, which provides a batch aging test to ...
Capacity: 216 l - 2,880 l
Temperature: 15 °C - 65 °C
Length: 1,200 mm - 2,300 mm
... Pharmaceutical Stability Chamber is used for intensive research in the pharmaceutical, medical, biotechnology industries, and related life sciences industries. The test chamber ...
Temperature: 35 °C - 103 °C
Width: 99, 78 cm
Depth: 79, 65 cm
... horizontally on its flat specimen tray. The Q-SUN Xe-1 tester is the simplest, most reliable, and easiest to use xenon arc test chamber available. A More Realistic Xenon The Q-SUN Xe-1 tester’s ...
Q-LAB
The Rapid Conditioning Cabinet has been specially designed and manufactured to pre-condition paper samples in an approximate 30 minute period, to the standard laboratory environment conditions by using the Laboratory air as the final ...
Capacity: 100 l
Temperature: -40 °C - 85 °C
... freedom to use the station mounted with the provided temperature chamber or not. This complete measurement station is a precise, economical manual solution which ensure high accuracy and stability. Applications • ...
Temperature: 2 °C - 45 °C
... and 6cm thick. • Full cooling system, 1/2 H / F -230V. • Air recirculation system distribution for even conditions in chamber. • Heating system. • One or Two Stainless Doors with Magnetic Seals. • Shut-off system ...
Capacity: 310 l
Length: 181 cm
Width: 99 cm
... kinds of rubber test pieces, such as flat foils, tubes, cables, bushings and seals. The test system is intrinsically safe. The front door is electrically interlocked and can only be opened when the chamber ...
Temperature: -40 °C - 100 °C
... Temperature Cycling Chamber is designed to apply temperature cycling on optical fiber cables in order to determine the stability behavior of the attenuation of cables submitted to temperature changes. ...
Capacity: 50 l - 2,000 l
Temperature: -70 °C - 150 °C
The Climatic Chambers for tests of photostability and photoperiods of Ineltec are designed to perform tests of aging to the light. They are able to perform any cool- heat- UV radiation ...
ineltec france
Length: 374 mm
Width: 520 mm
Depth: 320 mm
... range of sample holders make the process of assessing and grading the samples very clear. Pre-loaded images To grade other test methods including Martindale and Snag Pod. Standards driven For mace snag testing ...
Capacity: 120 l - 1,000 l
Temperature: 5 °C - 60 °C
The Osworld Photostability Chamber is designed specifically to meet ICH and FDA requirements for Photo Stability Testing. Calibrated photon detectors measure lamp intensity on the product shelf. Lamp ...
Osworld Scientific Equipments Pvt. Ltd.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining