- Detection - Measurement >
- Electrical Measurements >
- Other electrical measurement equipment
Other electrical measurement equipment
temperature calibratorTP 3M255E series
Temperature: -35 °C - 165 °C
Voltage: 110 V - 240 V
... Whether for on-site use in the workshop, in the measuring and test room or laboratory, SIKA temperature calibrators can be used everywhere. A wide range of industries and various application areas are covered. • assembly, commissioning • manufacturing, ...
SIKA
... 1.2/50µs lightning impulse generator up to 24 kV with 40Ohm impedance. High voltage outputs on top plate protected by TC-ST test cabinet. MIG2403 is a lightning impulse generator with voltage wave shape 1.2 / 50us. Applications range from insulation ...
... The heating device is heated by two sections of resistance radiation,it can realize 300-1000℃ experimental temperature, and have a good isotropical, temperature volatility and temperature gradient. In vacuum ,it can received GB. Use Level 0.1 AI Intelligent ...
... Extrusion lines for the production of PROFILES The patented MULTIDRIVE technology of the Bausano MD Plus extruder range and a long-standing experience in plastic processing allow Bausano to ensure high performance and great reliability over time. Bausano ...
Measuring transducers MT 4xx are intended for measuring and monitoring single phase or three-phase electrical power network. It has power accuracy class 0,5, according to the standard EN 60 688 and is intended for electricity distribution and energy production ...
Iskra d.d.
Temperature: 40 °C - 400 °C
... KT-H101/KT-H102 are small sized practical calibration equipment for temperature calibration of thermocouples and resistance thermometers. - Excellent temperature distribution is achieved by using a heat pipe. 100mm of long heat equalizing length ...
CHINO CORPORATION
... Digital Wattmeters The M4Y/M4W/M5W/M4M series digital wattmeters can measure the electric power in watts and display the values in numeric form. All models feature a 7-segment LED display for clear indication of measured values. The standard meters ...
... Copper earth bar 8 ways (M10 screws) with one disconnecting link. 8 way earth bar, made with 50 x 5 mm tape, enable connection of various cables or round conductors with tin-plated copper connection terminals (for instance, AT-093K). • Dimensions ...
Fully-automatic measuring dials and precision display testing device for analogue and digital measuring dials, as well as all types of measuring probes with a measuring range of up to 100mm. The measuring results are even more precise with image processing. ...
Steinmeyer Holding GmbH
Primary current: 1 mA - 200 mA
... •Small DC current' s measurements: DC1 mA~200 mA •High accuracy: ±1 %FS±20 mV •Least influence of magnetization: Less than DC1 mA in current level •Convenient Single Supply (+5 V) •Reference voltage (Vref) terminal is equipped. •For the detection of earth ...
... The TQC Low Voltage Pinhole detector enables the user to inspect various coatings on conductive substrates for small defects such as holidays and pinholes using the ‘wet sponge technique’. The grounding clamp is connected to an untreated piece of the ...
... Our kits are a great way to calibrate your Ion Science gas detector to ensure safe operation and functionality to meet your required regulations and code of practice. Our kits can be purchased with demand flow or flow regulators and can be supplied with ...
High-Current Test Probe up to 400 A for use in extreme production environments; compact design; Test of high currents possible; compensation for axial deviations and compensation of contact surfaces unevenness
PTR HARTMANN GmbH
... Handling Tools S&C Handling Tools provide convenient, easy operation of S&C fuses, cutouts, and disconnects, as well as those of other manufacture. Each tool consists of a detachable fitting specifically designed for a particular handling operation, ...
S&C Electric Company
Temperature: 20 °C - 30 °C
Transcom Electronic Calibration Modules (TECM) are ideal for users who want fast and easy calibration of various VNAs. (Refer to 1.2 Vector Network Analyzer Compatibility). This TECMs are powered up via USB or 5.5 DC connector and communicate with VNA ...
Sonel MPI-540-PV is an extremely universal meter, designed in particular for testing photovoltaic installations. The device allows a complete set of tests on the DC and AC side – in accordance with the guidelines of EN 62446 standard. Measuring parameters ...
Sonel SA
The Tester 1006 is made controlling 4 load cells of any weighing system at real time. This unit may be used as either calibrator or peak detector. It is fitted with an upload function for tools like DAT and MC 302. Also, this product is supplied with ...
Primary current: 100 A - 2,000 A
... •Closed loop (compensated) current transducer using an extremely accurate zero flux detector •9-pin D-Sub male secondary connector •Status signal to indicate the transducer state •LED indicator confirms normal operation •Metal housing to improve immunity ...
Primary current: 1, 5, 10 A
... An extensive range of transducers providing measurement, isolation and conversion of electrical parameters into industry standard DC output signals. The range offers protection against high voltage and overload, and resistance to vibration in harsh ...
Crompton Instruments
... This is a handy type calibrator that is highly portable. Leak standard can be generated simply by adjusting the dial. By changing the laminar. · Adjustable inlet pressure · This calibrator is compatible with a maximum of 3 flow-rate ranges · Bulid-in ...
Temperature: -196 °C - 420 °C
Voltage: 9 V
... Ellab Temperature Standard ETS10 The traceable ETS allows for extremely accurate temperature measurements by converting resistance into temperature using its built-in algorithms. When connected to the ValSuite software, the LiquiCal bath and ETS ...
Ellab Validation & Monitoring Solutions
Meet the next generation Hipot Tester. The new Hypot® Series raises the bar for safety and efficiency in production line Hipot Testers. Whether your application requires AC Withstand tests, DC Withstand tests, or Insulation Resistance tests, The Hypot ...
Associated Research
... Portable Audiometer Calibration System Model AudCal for Certification and Testing The new SoundAdvisor Audiometer Calibration System AudCal is a field-ready solution for fast, comprehensive audiometer calibration. The system combines the power and ...
Larson Davis
... - The device can be adapted to the mobile APP, WeChat applet, and web interface - The device is equipped with functions such as automatic time calibration, stopwatch, step counting, etc. - Long-term static detection, it will self-detect after static - ...
... SENSOR IQ EASY: THAT MEASURES THE ELECTROSTATIC CHARGE A sensor that measures the electrostatic charge of a web can be added to the IQ Easy platform. The Sensor IQ Easy is a bar type device that can hold op to 16 sensor heads. Each sensor head can be ...
Simco-Ion
The Uni 500 is the ideal testing tool for process development or when you begin to plan a series test – its maximum configuration masters the pressure decay/pressure rise, relative pressure/differential pressure and mass flow methods equally well, providing ...
Voltage: 30, 100, 300 V
Current: 1, 3 A
Power: 30 W
Wuhan Precise Instrument Co.,Ltd has been creating S series source measure unit for so many years.The source measure unit is similar to keithley smu 2400 2401 2450 which has high-precision,large dynamic range,digital touch screen, four-quadrant operation,collect ...
Wuhan Precise Instrument Co.,Ltd
... The capacitive measuring method enables a non-contact voltage measurement that can be carried out quickly and easily. The LED glow lamp starts pulsating as soon as the measuring tip detects a voltage in the localisation range, accompanied by an acoustic ...
Trotec GmbH
... The test can be carried out either in the field, on the wall or at the bottom of an excavation, or even in a laboratory on a suitably contained specimen. It consists of inserting a vane with four orthogonal blades into the soil, rotating it at the ...
... Our magnetic measuring and testing devices are best described by their key characteristics: compact, practical and cost-effective. These easy-to-operate tools play an important role in measuring the polarity and flux density of magnets during inward ...
ThyssenKrupp Magnettechnik
The FISCHER offers a comprehensive range of around 100 probes, designed to satisfy the requirements of an extremely broad application range. These units are designed to be very robust and highly resistant to wear and offer accurate measuring over an extended ...
... MFI magnetic field indicator – SAMFI Octagonal probe for checking the orientation of magnetic fields, quality of dry and wet magnetic powders and magnetization. Complying with standard ASME-ASTM-MIL-AMS. ...
S.A.M.A. ITALIA SRL
... • Measuring sensor with squared coil arrangement • For the quality control of electrical steel and other soft magnetic material • Construction according to IEC 60404-2 or according to customized requirements • Contra-inductivity to compensate air flux Measuring ...
Brockhaus
... ACS Test System consists of the AC power supply with voltage range of 25 - 100 kV and power range of 20 - 100 kVA together with PD and/or C & tan delta (dissipation factor) options. AC high voltage sources are used for dielectric proof tests on high ...
Haefely AG
... Wire Mapper Pro Model CA7028 The Wire Mapper Pro Model CA7028 is a hand-held structured cable mapping and troubleshooting tester designed for use on UTP, STP, FTP, and SSTP cabling equipped with RJ-45 connectors and wired to either TIA568A/B ISO11801 ...
AEMC Instruments
Voltage: 60 V - 400 V
... 0.02 class energy meter calibration device instrument Facing as many as dozens of single/three phase device in measurement checking center and Production Company, it is a challenge work to check and test to the device according to IEC 60736. While ...
SMS Electric Co.,Ltd.Zhengzhou
Temperature: -10 °C - 60 °C
Pressure: 45 psi
... AFS–Portable Gas Flow Calibrators A portable gas flow standard that is ready for anything When your calibration process requires the utmost accuracy, the AFS flow standard delivers. It features Alicat’s most advanced calibration for optimal performance ...
Alicat Scientific
... This device is designed to isolate 4/20mA signals between the safe and the hazardous areas. Input:Current (4/20mA) Output: Current (4/20mA) Supply: No power supply required Model: 1, 2 or 4 channels Setting: Adjustment potentiometer for the source on ...
GEORGIN S.A.
Temperature: 5 °C - 40 °C
Pressure: 20 psi - 40 psi
Voltage: 85 V - 265 V
... The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and ...
Teledyne API
Primary current: 0 A - 1,000 A
... Hall effect transducers ø 35mm To measure unidirectional direct or pulsating current (average value) Input up to 400A d.c. Standard signal output 0...20mA and 4...20mA or 0...10V Field-selectable output 0...20mA and 4...20mA 4kV input - output ...
IME Spa
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.