- Detection - Measurement >
- Electrical Measurements >
- Other electrical measurement equipment
Other electrical measurement equipment
... Measuring force - 240 N Max. perm. errors - ± (1,5 + L/100) µm, L in mm Repeatability - 1 µm Resolution - 0,001 mm Power supply - 100 ÷ 240 AC, 1,5 A, 50 ÷ 60 Hz Included in delivery - Declaration of conformity Data output(s) - RS232 The maximum ...
... For comparative and direct measurements • Direct measurement of gauge blocks with a variation in nominal length of up to 25 mm or 1 in. – Enables the number of reference gauge blocks required to be reduced by nearly 80 %. • Comparative measurement ...
... For comparative measurements • Measures gauge blocks of same nominal length by comparison. • Comes with the new template system for positioning the gauge blocks. • Single or dual template system for optimum ease of gauge handling. • Features TESA ...
Temperature: 50 °C - 1,000 °C
At a retort volume of 36 liters (diameter 300 mm, depth 510 mm) the waste gas-free and environmentally friendly system THERMOCAL TH 500-12 offers approximately seven times the capacity of the TH 050 and is therefore suitable for the calibration of larger ...
All Genuine GurleyTM bending resistance/stiffness testers are based on the same physical principle. each instrument consists of a balanced pendulum or pointer which is center-pivoted and can be weighted at three points below its center. The pointer moves ...
... ►For monitoring piston position on pneumatic cylinders ►Non-contacting and wear-free for long service life ...
... With the TABER® Shear / Scratch Tester, you can evaluate resistance to shearing, scratching, gouging, marring, scraping and engraving on a variety of flat, rigid specimens. It may also be used to test the relative homogeneity of materials, the adhesive ...
The TABER® Multi-Finger Scratch / Mar Tester - Model 710 is used to measure the relative resistance or susceptibility of a material surface to scratching, marring, gouging, scraping, engraving and other similar physical damage not classified as ordinary ...
... ELECTRIC AND MAGNETIC FIELD DETECTION Isotropic sensors with RMS response WEIGHTED RESPONSE TO INTERNATIONAL STANDARDS ICNIRP, European Directive 2013/35/EU, FCC and Safety Code 6 (2015) HIGH INTENSITY AUDIBLE, VISIBLE AND VIBRATION ALARM With user ...
WAVECONTROL
... ELECTRIC FIELD DETECTION Isotropic sensors with RMS response WEIGHTED RESPONSE TO INTERNATIONAL STANDARDS ICNIRP, European Directive 2013/35/EU, FCC, Safety Code 6 (2015) and NATO INSTANT AND AVERAGE VALUES Alarms on instant and average values. Configurable EXPOSIMETER ...
WAVECONTROL
... STATIC FIELD DETECTION 0 Hz - Isotropic hall effect sensor LOW FREQUENCY DETECTION 10 Hz to 400 kHz - Isotropic coil-based sensor ACCORDING TO ICNIRP GUIDELINES For general public and occupational exposure EXPOSIMETER WITH DATALOGGER Data collecting ...
WAVECONTROL
... II2(1)G Ex eb mb ib [ia Ga] IIC T4 Gb II2(1)D Ex tb ib [ia Da] IIIC T130°C Db Universal transducer for mounting in zones 1 / 2 / 21 / 22 Ambient temperature -40…+70°C IP66; Temperature class T4 for all gases and dusts Parameters can be set on site; ...
... SPDT Changeover surface mount (SMD) MK01 Series Reed Sensor used in On/Off control switch, proximity, motion, position detection with high power switch option. Supplied in tape and reel according to IEC 286/part 3. UL Approval Specification Contact ...
StandexMeder Electronics GmbH
M5/M8 adjustable thread mount MK11 Stainless Steel Series Reed Sensor are supplied in a cylindrically shaped housing with cable terminals. Used in position, level, and end limit detection w/convenient sensing adjustment. Optional internal switch, cable, ...
StandexMeder Electronics GmbH
M8 adjustable thread mount MK11 Plastic Series Reed Sensor are supplied in a cylindrically shaped housing with cable terminals with optional high voltage switch. Used in position, level, and end limit detection w/convenient sensing adjustment. Optional ...
StandexMeder Electronics GmbH
... SENSOR IQ EASY: THAT MEASURES THE ELECTROSTATIC CHARGE A sensor that measures the electrostatic charge of a web can be added to the IQ Easy platform. The Sensor IQ Easy is a bar type device that can hold op to 16 sensor heads. Each sensor head can be ...
Simco-Ion
The Perfomaster provides the hardware and software to generate a controlled spark over, detect this and evaluate the spark over to produce a pulse signal. The pulse signal is available on the output connector and can be used for counting the detected ...
Simco-Ion
In order to detect perforations in a moving material web, this special electrode is equipped with a resistance per emitter. When a perforation passes the electrode, there will occur a controlled spark over. This is detected by the associated CM5 high ...
Simco-Ion
... Variable flow rates Easy to use Clear display Shut-off valve The FCO210 is ideally suited to the calibration of production line leak detectors, fault finding and system checking. Easy to use, adjustable, accurate, and portable, the FCO210 sets the ...
... Differential pressure measurement down to 0.01 Pa. Automatic differential pressure generator Measure: Differential pressure, flow, temperature & pressure Data-logging facility with USB and RS232C output Detailed and easily-readable graphical display Used ...
Pressure: 0 Pa - 44,000 Pa
... - A unique primary standard for low-pressure scenarios - Pressure calibration range from 0.001 Pa to 44k Pa - Typical uncertainty of ± 0.005 % reading + 0.02 Pa - Used worldwide in national & accredited laboratories - New 2017 version ...
Capacitec’s HPC cylindrical probes are the most popular of its non-contact line of capacitive sensors due to the ease of installation to measure an earth grounded target. The sensor and guard elements are provided in a protective outer case to prevent ...
... Capacitive Displacement Calibration Stands Capacitec customers have the option of performing calibrations in house or sending the system back to Capacitec for factory recalibration. Recalibration every 12-24 months is typical, depending on the application ...
... Overview
Impedance voltage exceeds national standard and system impedance does not exceed 5%. Compact dimensions and low weight. Automatic control improves automation level and anti-interference capability.
Product parameters
Oil-immersed ...
Wuhan UHV Power Technology Co.,Ltd.
... Overview
The UHVIW Series non-partial-discharge fault simulation test device is designed for on-line installation and testing on energized high-voltage equipment (including GIS). The instrument digitizes signals via high-speed AD conversion ...
Wuhan UHV Power Technology Co.,Ltd.
... The DBF multi-frequency induction withstand voltage tester is designed for induction dielectric withstand tests on transformers and mutual inductors. It is portable, easy to operate and available in multiple power ratings for on-site electrical testing.
Key ...
Wuhan UHV Power Technology Co.,Ltd.
RAEM1-6 is a multi-channel intelligent IoT acoustic emission monitoring system that integrates automatic control signal acquisition, processing and analysis, data storage, clock synchronization and wireless communication. RAEM1-6 is a stand-alone AE instrument, ...
QAWRUMS Ltd.
RAEM1 system is a complete full function single channel AE system not only for remote wireless long term non-destructive monitoring applications but also for standalone local detection purposes. RAEM1 is a single channel AE system integrated with AE sensor, ...
QAWRUMS Ltd.
SAEU3H is a multi-channel acoustic wave (acoustic emission) acquisition and processing benchtop type AE system. A complete SAEU3H system is composed of a certain number of AE acquisition boards in a chassis, AE sensors, preamplifier, coaxial cables and ...
QAWRUMS Ltd.
... Product overview
Self-powered signal converter with galvanic isolation for current-loop monitoring. Provides a self-powered galvanic isolator and a separate 4-20 mA 2-wire output driven from an external supply.
Features
- Format:
... Overview
DIN-rail signal converter CV/1 with integrated power supply. Configurable device for converting temperature sensor signals, standard voltage/current loops and AC current measurements. Compact housing designed for industrial control ...
... Product features
- Selectable input/output ranges with front panel switches:
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V input
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V output
- 3 way isolation
- 20 VDC transmitter
Datcon Industrial Electronics Ltd.
... Product features
- 4-20 mA passive current output
- Selectable input ranges with front panel switches:
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V
- 3 way isolation (input/output/power supply)
- 20 VDC transmitter
Datcon Industrial Electronics Ltd.
... Product features
- freely configurable inputs/outputs via USB port
- -125 – +125 V / -2.5 – +2,5 V / -25 – +25 mA input ranges
- 0-22 mA / 0-10.5 V output ranges
- 3 way isolation (input/output/power
Datcon Industrial Electronics Ltd.
... Product Overview
KLC Corporation provides high-voltage electrostatic control technology and related system integration solutions, developed with more than 20 years of expertise in electronic design and manufacturing. This page is intended for ...
... The seam probe electrode is used to test seams and lap joints in single ply membranes. The tool fits directly into the handle or the extension rod of the Dry Roof Pro2, enabling the user to test lap joints/ seams from a standing position, whilst applying ...
Buckleys (UVRAL) Limited
Voltage: 0 V - 40,000 V
... The Buckleys Calibration Meter Pro’ offers a quick, accurate and cost-effective method of checking the calibration state of high-voltage DC equipment. It has been primarily designed for use with the Buckleys’ PHD Pro’, PD and PHD range of Pinhole/Holiday ...
Buckleys (UVRAL) Limited
... The Calibration Kit has been created to provide all the necessary components to enable customers to verify the accuracy of the readings on the Buckleys or Roxby BathyCorrometers so that ‘in-house’ calibration certificates can be issued. The process ...
Buckleys (UVRAL) Limited
Primary current: 2 mA - 15 mA
MD0630STA-P earth leakage sensor detect both AC and DC ground faults in a very small, PCB-style form factor. The RCD module is designed for integration directly into inverters. Outputs way is open collector output. With the characteristics of high sensitivity, ...
IVY METERING
Primary current: 3 mA - 100 mA
AC/DC sensitive residual current detection device model MD0630T01A is a specialized leakage current sensor designed for electric vehicle (EV) charging stations. This sensor is engineered to ensure the safety and reliability of the EV charging process. ...
IVY METERING
Primary current: 5 A - 60 A
... Product overview
- Current range: 5(60) A — secondary reference: 2 mA
- Accuracy class: 0.1
- Coil turns: 2500 turns
- Rated burden: 20 Ω
- Dielectric strength: 4 kV
- Rated frequency: 50–60 Hz
- High-precision
IVY METERING
... PW636i-F (6×32A, 4×300V, 8 fiber optic ports) is the new generation of PW series relay test set which can be used both as an conventional relay test kit and IEC61850 testing tools. It is equipped with 6 current output, each channel 32A/450VA output, ...
PONOVO POWER CO., LTD
PCT200AX Portable CT/PT Testing System (CT PT analyzer)-Battery Supply Type is a test equipment specially designed for current transformer and voltage transformer characteristic test. Compared with PCT200X, the accuracy of PCT200AX is higher. The test ...
PONOVO POWER CO., LTD
PCT200AX Portable CT/PT Testing System (CT PT analyzer)-External Power Supply Type is a test equipment specially designed for current transformer and voltage transformer characteristic test. Compared with PCT200X, the accuracy of PCT200AX is higher. The ...
PONOVO POWER CO., LTD
The laboratory decade RLC-D1000 is equipped with three independent sections for resistance, inductance and capacitance, adjustable in a wide range of values. Individual quantities are galvanically separated from each other and have separate outputs. Values ...
Diametral a.s.
The Uno Volta panel set is designed for teaching and experimenting in wiring and measuring electrical circuits in many fields of electrical engineering and electronics. Individual areas of electrical engineering are processed on separate panels that can ...
Diametral a.s.
The Uno Volta panel set is designed for teaching and experimenting in wiring and measuring electrical circuits in many fields of electrical engineering and electronics. Individual areas of electrical engineering are processed on separate panels that can ...
Diametral a.s.
... Product
SBS080 is a DIN-rail mounted signal converter with isolated power, designed to convert potentiometer or sensor signals into standardized voltage or current outputs for control and monitoring systems.
Characteristics
- Isolated
SENTOP by Shanghai Sibo M&E Co., Ltd.
... R12S 1-turn Contactless Magnetic POT. Magnetic rotary sensor (Hall effect) High protection degree Pocket size (Housing dia.Φ12mm) With one couple of precision ball bearings Servomount Mechanical angle 360º(Endless) Protection degree IP65 Operating ...
SENTOP by Shanghai Sibo M&E Co., Ltd.
... WDH15B 1-turn Contactless Magnetic POT. - Magnetic rotary sensor - Economy version - Small size (Housing dia.Φ15mm) - With one couple of precision ball bearings - With solder terminals Gerneral Mechanical Specifications - Mechanical angle: ...
SENTOP by Shanghai Sibo M&E Co., Ltd.
Temperature: 15 °C - 35 °C
Pressure: 0 bar - 0.6 bar
Humidity range: 0 % - 80 %
... Overview
The YUNYI XY-4002 sphygmomanometer calibrator is a bench instrument designed for metrological verification of blood pressure devices in accordance with JJG270-2008 and JJG692-2010. It integrates microprocessor control, dedicated pneumatic ...
Xi'an Yunyi Instrument Co., Ltd.
Pressure: 0 MPa - 250 MPa
The Automatic Pressure Controller, is a high-precision, fully automatic pressure calibrator designed to meet the demands of modern industry. This device offers a variety of pressure range options, suitable for pressure calibration and control in both ...
Xi'an Yunyi Instrument Co., Ltd.
Pressure: -10,000 Pa - 10,000 Pa
... This Microdifferential pressure gauge calibrator is composed of the micro generation pump,standard gauge and the differential gauge bracket.It use high-quality stainless steel and aluminum alloy materials and the seals and connectors imported from ...
Xi'an Yunyi Instrument Co., Ltd.
... Non-contact ground resistance measurement: 0.025Ω ~ 1500Ω No auxiliary electrode needed Leakage current measurement: 0.3mA ~ 35A, True RMS Jaw diameter: 35mm Programmable High and Low alarm Programmable data logging Data logging capacity: 116 records Data ...
TES Electrical Electronic Corp.
Temperature: -10 °C - 50 °C
Pressure: 1,013 mbar
Noise level: 114, 94 dB
... Accurate and Simple to use Fits 1”, 1/2” or 1/4” diameter microphone Output Frequency 1000Hz ±2% Reference Conditions TEMPERATURE →20°C(68°F) ATMOSPHERIC PRESSURE →1013 mbar (760mm of Hg) RELATIVE HUMIDITY →65% Accuracy of Sound Pressure ...
TES Electrical Electronic Corp.
... Use rechargeable lithium-ion battery pack Frequency range 10MHz to 8GHz. 3 axis isotropic measurements of EMF. Non-directional (isotropic) measurement with three-channel measurement probe. High dynamic range. Configurable alarm threshold and memory ...
TES Electrical Electronic Corp.
The MAP4-DC12 module allows the measurement of 12 direct current circuits. It is powered by the MAP4-DC9 central unit and features a 4V DC current input for Hall effect current sensors. This module is designed for DIN rail mounting, with a 4-module width ...
Lettel
Primary current: 0 A - 5 A
... Description
The summators allow adding the currents measured by several current transformers. The MTCS sums the currents measured by 2, 3 or 4 current transformers installed on different circuits of the same phase.
Characteristics
- Inputs
Lettel
Primary current: 50 A - 600 A
... Presentation
Open-loop Hall-effect current sensors with Ø21 mm opening for primary currents from 50 to 600 A (depending on model).
Description
The MTCCO series of Hall-effect current sensors combines measurement accuracy with ...
Lettel
... Product description
Evaluate measurement data from various sensors with standard industrial signals. Requires a computer with a free USB or RS-232 port. The connected computer communicates with the converter via Modbus RTU. The S2C-2 provides ...
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group