Temperature: -200 °C - 2,300 °C
New challenges require new tools. TEGAM has rethought thermocouple calibration to offer you the performance you need today without complicating your work. The new 940 Series handheld thermocouple temperature calibrators provide laboratory-grade temperature ...
TEGAM
Temperature: 0 °C - 1,200 °C
Weldotherm® recommends this robust precision measurement and calibration device for use on construction sites. Through the use of a toggle, temperatures can be simulated or measured precisely. The measurement device has a built-in reference junction to ...
Hertzinno overhead line fault indicator is a transmission line fault locating system support interval fault location with features such as self-organizing network capability, strong adaptability to various conditions, zero false alarms and long lifespan. ...
... * Professional, 125 Hz/94 dB sound source. * Die casting aluminum alloy housing case. * DC 9V batteries x 2 PCs. * Size : round 50 mm Dia. x 145 mm ( length ). ...
Lutron
... Product Details
- Underground bushing probe for Radio Voltstik.
Characteristics / Technical Specifications
- Model Number: 7-124
- Subtitle: Underground Bushing Probe
- Compatible with: Radio Linked Voltstik
SENSORLINK
... Next generation SRV Testing Machine designed to test lubricant, grease, additives, and materials in high-frequency linear oscillation motion. Main Features: 10 µm – 2.8 mm stroke / 0.1 mm to 5 mm stroke Up to 300/500 Hz oscillating frequency High-resolution ...
RTEC Instruments
... Decade resistance box 4 decades resistance box - Accuracy : 1 % (0,5 % resistors) - 1 Ohm to 11,110 K Ohms - Output of each decade on safety socket - Robust switches. - 19" standard rack size front panel. 0.1 - 11.11111 MΩ ...
ELC construction électronique
Temperature: -100 °C - 10 °C
... The world’s first self-contained transportable dew-frost point calibrator Primary saturator humidity generator – fundamental precision Transportable – suitable for use in the laboratory or on-site Self-contained – no need for external services -100… ...
... DIFFERENTIAL PROBE P9000 Easily Connect to Hioki Memory HiCorders and HiLoggers for High Voltage Testing Overview • - Compact probe for CAT III 1000V environments • - Wave mode: Observe instantaneous waveforms • - RMS mode: Observe RMS value ...
HIOKI EUROPE GmbH
Pressure: 2,000 bar
AEP transducers
... 2P and 3P earth measurements 3 resistance measurement ranges Delivered in a carry case with earth testing kit: - 3 cables with crocodile clips - - 1 double cable for the 2P method - - 2 earth testing rods Safety: Cat. III 30V (IEC 61010-1) ...
MULTIMETRIX
... 500VA AC Test Capacity 240x64 Ice Blue Dot matrix LCD Sweep Function for DUT characteristic analysis Insulation resistance measurement up to 50GΩ(GPT-9903/9904) Manual/Auto Mode Function Key for quick selection High intensity ...
Instek
Temperature: -20 °C - 60 °C
Voltage: -100 V - 100 V
... •Calibrate Milliamp Instruments Source 0.00 to 24.00 mA & -25.0 to 125.0% of 4-20 mA Read 0.00 to 52.00 mA Read -99.99 to 99.99 V Simulate 2-Wire Transmitters; Power & Read 2-Wire Transmitters •Calibrate with Confidence Accurate to ±0.025% of ...
PIE - Pratical Instrument Electronics, Inc
... 3-way CURRENT ISOLATOR, 1.5 kV galvanic isolation, suitable for isolating a 0-4…20mA signal, ready to be mounted on DIN rail. Analogue output in active and passive current. INPUT: 0…20 mA, input impedance 20 ohm, max resolution 2uA; OUTPUT: 0…20 ...
qeed
Primary current: 10 A - 15,000 A
... C104.CT Primary: from 10A up to 15000A Output: 5V or 7.5V Power supply (external) : from 36Vdc to 150 Vdc Cable diameter 104mm Starting at: 2239 euros ...
UNIVERSAL TECHNIC
... COMECO’s signal isolator TRI is a compact 2-wire current-to-current transmitter providing optical isolation between the input and output current loops. The isolation level is normally 2500 VAC, but can be increased optionally to 4000 VAC. The TRI current ...
Temperature: 40 °C - 375 °C
The LHC 75 dry block temperature calibrator is a compact and lightweight device, suitable for all conditions and applications, covering different types of industries. The LHC 75 calibrator is the most advanced device in its class. Designed to work in ...
Leyro Instruments
Voltage: 0 V - 6 V
Current: 0 A - 5 A
... N9000 BMS Testing Modular Battery Simulator(12CH/24CH/36CH) N9000 series is a high real-time, high-synchronous, high-power measurement and control platform, consisting of N9000 measurement and control chassis and a variety of modules. N9000 is a standard ...
NGI Tech
... The G.R.A.S. 42AB Sound Calibrator is a small battery-operated precision microphone calibrator. The calibrator can be used directly on 1" microphones and ½" microphones. Adapters for calibrating ¼” microphones and ⅛" microphones are included. Typical ...
G.R.A.S. Sound & Vibration
... 4310-d4-IEC Serie Designation : 4310-d4-IEC Serie Electic protection : 1000 V CAT II, reinforced insulation, pollution degree 2, up to 36 A. Cable type : PVC 0.75 mm² (AWG18) (12 A), PVC 1.00 mm² (AWG17) (20 A), PVC 1.50 mm² (AWG15) (25 A), PVC 2.50 mm² ...
ELECTRO PJP
DISTRIMESURE - iMesure
Temperature: 10 °C - 50 °C
Voltage: 0 V - 5 V
... Based on Edgetech Instruments field proven chilled mirror sensor technology A completely self-sufficient and portable humidity calibration system Temperature and relative humidity controlled independently for custom humidity generation High accuracy ...
... -Multicolour display -5 digits 11mm high & bargraph -Current, voltage and RTD input -Noryl or rugged 316 stainless steel enclosure both provide IP66 front of panel protection. -Max and min display -Tare function -dc and mains powered models -Easy ...
Temperature: -24 °C - 140 °C
Voltage: 12 V
... Portable calibrators have a quick response time and good accuracy and stability, which means that they can calibrate temperature sensors both in a lab and on the field in a short time. Liquid calibrators consist of a cylindrical container of about ...
GIUSSANI SRL
Temperature: 14 °F - 122 °F
Pressure: 50 psi - 10,000 psi
... Speed through Calibration Tests With single button logging of both Device Under Test (DUT) and Reference readings, techs get completely digital logging of test points. Instant tolerance feedback at each point lets you know sooner than later whether ...
Ralston
... A gas preparation device for calibration of a flow ratio mixing system for the purpose of using calibration of an atmospheric sulfur dioxide analyzer, a nitrogen oxide analyzer, and a carbon monoxide analyzer. A zero gas generator is built in, and purifies ...
Temperature: 40 °C - 375 °C
Voltage: 234 V
... Universally applicable and portable Blockcalibrator for immersion-and insertion probes (e.g. Pt 100, Thermocouples) between +40...375°C • Large measuring range +40 ... 375 ° C • 230 VAC power supply • 120mm immersion depth Various interchangeable ...
... URYXXON® Relax – automated urine analysis at the point of care The URYXXON® Relax provides dependable urine status results to detect early stages of many diseases such as diabetes, kidney disease and urinary tract infections. Instrument-read results ...
The non-contact voltage tester Testboy 105 detects voltage-carrying conductors from 12 V AC. Due to optical, acoustic and vibrating indication, it is especially easy and reliable to use. Due to the capacitive measurement procedure, invisible interruptions ...
Testboy
Frequency: 1,176 MHz - 1,606 MHz
Gain: 0.9 dB - 1.3 dB
... With a footprint of 25x25x12 mm only, The 2JM3201C3F is the most compact, high precision, low profile internal ceramic active stacked patch antenna with L1 and L5 bands on the market. 2JM3201C3F offers reliability, greater bandwidth, and high gain by ...
Primary current: 20, 50, 100, 200 A
DENT Mini and Midi Hinged current transformers are high-performance hinged current sensors designed for use in energy metering, load survey, demand metering, energy audits, and submetering applications.They are ideal where space is limited, such as when ...
DENT INSTRUMENTS
Temperature: -20 °C - 60 °C
Pressure: 1,000 bar
Voltage: 0 V - 10 V
... Accurate, high resolution, compact, rigid Pressure ranges from 0...250 mbar to 0...6000 bar, as well as vacuum, compound and absolute ranges Changeable reference pressure sensors LR-Cal LPC-S All standard pressure units (plus one self-definable) Conversion ...
DRUCK & TEMPERATUR Leitenberger GmbH
Pressure: 800 mbar - 1,150,000 mbar
... CO2 Zero Calibration Kit for the Guardian NG The Zero Calibration Kit acts as a convenient alternative to bottled gas for checking zero offsets and if necessary, zero calibration. It works by removing the CO2 from the air being drawn into the instrument, ...
... TSC200 is a 1-Wire current sensor with 0.3 to 15A working range and IP30 protection. TSC200-15 is a galvanic isolated 1-Wire current sensor. The sensor provides a low-cost option for AC or DC current monitoring. The 1-Wire sensor is based on fully integrated ...
Teracom
... P18 and P18D transducer are devices destined for the continuous measurement and conversion of relative humidity and ambient temperature into a digital or analog standard signal. Additionally P18D transducer is equipped in LCD display. The transducers ...
... P18 transducer is a device destined for the continuous measurement and conversion of relative humidity and ambient temperature into a digital or analog standard signal. The transducer programming is possible through the RS-485 interface and free eCon ...
DITEL
... Highly efficient pocket-size visual fault locatorthe ideal complementary tool for any fiber-testing technician. The FLS-140 is the easiest way to identify optical fibers from end to end and locate polished connector endfaces. Its red laser shines through ...
EXFO
... - Visually identifies and locates faults in fibre optic cabling - 2.5mm universal adaptor for all ST, SC and FC connectors - Useful over a distance of 5km (3 miles) - Up to 80 hours of operation - Ruggedised aluminium body The Visual ...
... Product Overview
The IT-5 Insulator Tester provides line crews a quick, concise method to assess porcelain and glass insulators for contamination, conductivity and internal defects on energized or de‑energized lines. It delivers clear visual ...