The JUMO dTRANS T06 Junior multifunction four-wire transmitter is the solution for a wide range of applications in plant engineering due to its galvanic isolation and customer-specific linearization. This entry-level ...
... thermocouple (TC), resistance thermometer (Ω), voltage transmitters (mV) HART ® protocol for converting various input signals to a scalable 4 to 20 mA analog output signal. Operating the transmitter ...
... include: Selectable HART 5 / 7 Digital Protocol Output (-J version) 17 Input Types Head Mount or DIN Rail Mount Variety of Sensor Inputs The type of sensor input is user-selectable: RTD, Thermocouple ...
This intelligent threshold detector/transmitter with an extra large display is specifically designed to monitor limit values or an ON/OFF or continuous control loop. Two versions are available: the 8400 Compact and 8400 ...
OPTITEMP TT 53 R The OPTITEMP TT 53 R is a universal, programmable, 2-wire rail-mounted temperature transmitter. The galvanically isolated transmitter works with RTD elements, thermocouple ...
... categories : Hockey-puck transmitter, In-head temperature transmitter Technical data Transmitter mounting : Head-mounted Galvanic isolation : No Transmitter ...
RTD, TC, mV signal transmitter, DIN/B or DIN rail head mounting -With 3 customizable linearizations (up to 96 segments) -Reversible output (e.g. 20 to 4 mA) -Programmable retransmission ...
DIN rail Transmitter for PT100 -Input from PT100, 2 wires output -SMART, programmable -Burnout, scale ranges and units of measure (°C-°F) programmable -Programmability with dedicated ...
Din rail Transmitter for Thermocouples -Thermocouple input, two-wire output -SMART, programmable -Burnout, scale ranges and units of measure (°C -°F) programmable -Programmability ...
The SERIES 5750 temperature transmitter yields remarkably accurate temperature measurements and improves reliability, which reduces downtime and costs. It offers new measurements with ...
transmitter, display, meter and controller in one package integrated radial temperature or temperature and humidity probe, Ø18 mm, L=40 mm, stainless steel 316L, PTFE filter ...
... voltage to current in the 4-20 mA standard transmitter, and has possibility of data reading via RS-485 interface. It has one input (Pt 100/500/1000, thermocouples K/S/J/T/N/R/B/E, 0-60 / 0-75 / 0-100 ...
... according to PN-EN60751+A2:1999 standard. Module allows conversion from temperature (RTD) to the current value in 4-20 mA standard. Measurement value is transmitted to the current loop ...
... high-accuracy loop-powered head mounted temperature transmitter, it accepts several types of temperature sensors – thermocouples, Pt100, Pt1000, NTC and 0-50 mV signal – all-in-one model, ...
Novus Automation Inc.
... Pt1000 - Temperature effect <± 0,16% @ 25º C - Configurable output to 4-20 mA loop powered or 0-10 V - Output Linearized according with measured temperature - Output ...
Novus Automation Inc.
The BTS Series (Built in Transmitter Sensors) sensors are mounted with the NOVUS TxMini temperature transmitter, which converts the output to 4-20 mA (2-wire loop powered), ...
Novus Automation Inc.
... industries, where a large range of temperatures are possible. This product has been successful in the Oil and Gas, Petrochemical, Power and Water industries. Key Features High accuracy ±0.075% 4-20mA ...
... configuration the transmitter can work alone without connecting to a power source. Technical Data Microprocessor Based DIN Rail Mount Configurable without external Loop Power Connected ...
... thermocouple type K, J, R, Sf T, N, E, B and RTD PT100Q from a PC Working Span Range: Programmable from a PC LCD Display: 5 digital (-9999-69999) Sensor Failure Protection: Programmable burnout upscale or downscale Connection ...
... For transmitters including humidity and temperature measurements, the models HMT120 and HMT130 are recommended. The measurement probe of the instrument can be easily removed and replaced with a new ...
... (DIN 43760) and retransmits it into a normalized current signal via a 4..20 mA loop-powered (2-wire technology) with 16-bit resolution. The transmitter is characterized by a high operating temperature ...
... potentiometer, mV, and retransmits it into a normalized current signal through a 4..20 mA loop-powered (2-wire technology) with 16-bit resolution. The transmitter is characterized by a high operating ...
... Loop Power 18~32 Vdc 。DCV Input: 0~500 mV/ 0~1V/ 0~5V/ 0~10V/ 0~20V 。DCA Input: 0~20 mA/ 4~20 mA 。Thermocouple Input: K / J / T / E / R / S / B / N 。RTD/ Resistance Input: PT100/0~400W 。Analog Output: ...
... Operating temperature -40…85°C High accuracy and resolution High reliability Programming via the USB interface Areas of application: The NPT3 is designed for universal use in industrial applications. ...
... use in industrial applications. These temperature transmitters can be applied to all automation systems in which different types of temperature sensors are used and output ...
Customised matching of the temperature measuring range Standardized output signal for simple implementation Fast customization thanks to modular product design Compact and reliable design
... element Pt100 class A DIN EN 60751 • Double-wall sensor tube as weather protection • Analogue output 0...10 V or 4...20 mA The Transmitter MTA90 for temperature ...
... via DIP-switches • Sensor tube 9 mm stainless steel 1.4571 • Analogue output 4...20 mA • Plastic housing with protection class IP 65 The MINI90-P series is designed for temperature ...
• Transmitter for connection to a Pt100 element , mV transmitter or potentiometer • Measurement and span from the front by trimmer • Operating temperature 0…50 ° C • Supply voltage ...
... suitable for bad surge voltage occasions. LG200 integrated temperature transmitter provides a flexible and reliable solution for any temperature measurement applications. Advantage • ...
... programmable temperature transmitter with microprocessor - 2-wire temperature transmitter suitable for head or field mounting. - It accepts signal from 13 types of ...
The temperature transmitter GV4730 MiniTherm is designed for the installation in a separate thermowell. Due to the design the transmitter is suitable for highest requirements. The 4 operation ...
Features:Cost effective. ZERO / SPAN adjustment. Sensor type:RTD Pt100(3-wire) Measuring range:-50 ... 400°C Output:DC 4 ... 20 mA(2-wire) Accuracy:±0.1% F.S. IP rating:IP30(Housing) / IP10(Terminal)
Features:Compact size. Easy to install. Cost effective. Sensor type:RTD Pt100(3-wire) Measuring range:-50 ... 200°C Output:DC 4 ... 20 mA(2-wire) Accuracy:±0.1% F.S. IP rating:IP30(Housing) / IP10(Terminal)
Features:Suitable for industrial application. Integrated design combines PT100Ω and transmitter. Easy installation. Sensor type:RTD Pt100 Measuring range:-50 ... 200°C Output:DC 4 ... 20 mA(2-wire) Accuracy:±0.5% ...
The APT-2000ALW is a temperature transmitter that is capable of generating an output signal that ranges from 4 to 20 mA. Integrated with a range that can be easily programmed, zero shift ...
APLISENS S.A.
... by Aplisens, is a temperature economical transmitter that has a programmable measuring range and an output of 4 - 20 mA. In addition, this product has an input signal of Pt100 and Ni100, ...
APLISENS S.A.
The ATX-2 Model is a programmable temperature transmitter developed by Aplisens. Its programmable sensor type is Pt100 and Ni100. This product is equipped with a relay output of 4..20mA, ...
APLISENS S.A.
Temperature transmitter with PT100 sensor and high response speed due to the mechanical dimensioning of the probe. The resistive value determined by the temperature variation is electronically ...
Head mounting transmitter. Programming via PC interface. 4-20 mA output 2 wires (optional HART protocol). Input resistance thermometers (PT100, PT1000, Ni100, etc.) or thermocouples (J, K, T, R, S, T). ...
... excitation supply for the transmitter used, the switching power supply willprovide installation convenience. The top and designed power supply, input and output indicators ...
TT Temperature Signal Transmitter (Head Mounting) FEATURES: ● Output: 4~20mA (2 wire) ● Accuracy: T/C: 0.3% Pt100Ω: 0.15% ● Wide selection of input with difference sensor type ...
TS 2 Wire Temperature sensor & Transmitter ● Accuracy: RTD: 0.5%, T/C: 0.75% ● Wide selection of input ● Low output ripple ● High stability & low cost
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining