- Robotics - Automation - Industrial IT >
- Automation >
- IP67 I/O module
IP67 I/O modules
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
In addition to the ICE1 masters for PLC-based applications, two other modules are available for use in cloud-based and hybrid systems: the ICE2 (EtherNet/IP) and ICE3 (PROFINET) IO-Link master series. These support the industry’s leading protocols, including ...
The R95C is an IO-Link device hub that consolidates and sends discrete or analog signals to an IO-Link Master over a standard M12 cable. The R95C features eight input ports. For discrete hubs, each input port has two discrete channels (either PNP or NPN). ...
Featuring industry-standard top-exit M12 connectivity and 16 discrete PNP inputs, the R130C cost-efficiently integrates up to 16 non-IO-Link devices into an IO-Link system. Its compact size, along with IP65, IP66 and IP67 ratings, allow it to be mounted ...
... Overview
Banner's RSio Remote Safe I/O block delivers In‑Series Diagnostics (ISD) and six independently configurable hybrid I/O ports for integration into CIP Safety™ systems. Two configurable outputs provide control signals for final switching ...
... Very safe mounting and high protection rating Digital inputs and outputs Fast detection and processing of analogue inputs Toolless mounting Three freely selectable directions of the flat cable ...
... High vibration resistance due to full potting Sensor and actuator supply also possible with external voltage Reliable detection and display of peripheral and communication faults Addressing via infrared interface With digital inputs ...
... For the simple connection of binary sensors to any IO-Link master Data and energy transmission also possible with unscreened connection cable Clearly visible LEDs for displaying operation, switching status and error Robust design with full ...
With the PDP67 modules, Pilz offers solutions for decentralised applications directly in the field. Protection type IP67 means that the modules are resistant to dirt and water. The decentralised modules optimise installation and wiring work. They save ...
... • Safety fieldbox for EtherNet/IP with CIP-Safety • For connection of up to 8 safety switching devices • Integrated dual-port switch • Protection class IP66, IP67 ...
... PROFINET device, EtherNet/IP device or Modbus TCP slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2 × M12, 4-pin, D-coded, Ethernet fieldbus connection PROFINET S2 system redundancy Glass ...
TURCK
... Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics Protection classes IP65, IP67, IP69K M12, 5-pin, L-coded male connector for power supply Galvanically isolated ...
TURCK
... PROFINET device, EtherNet/IP device or Modbus TCP slave Integrated Ethernet switch Supports 10 Mbps / 100 Mbps 2x M8, 4-pin, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration ...
TURCK
... The flexible and safe series connection with diagnostic function The Flexi Loop safe series connection allows you to connect up to 32 safety sensors up to PL e: With the Flexi Loop components, connecting safety locking devices, pushbuttons and lights ...
... Our Bulletin 1732 ArmorBlock® Guard I/O™ modules provide all the advantages of traditional distributed I/O for safety systems. These modules are available in an IP67-rated packaged for EtherNet/IP™ and are ready to mount directly on your machine. • ...
... Two programmable and supervised outputs ideal for alarm devices One special output for fire-door closing controlled by: Control expression Mains failure Loop communication error Tested and approved according to EN54-18 CPR: 0786-CPR-21201 Specifications Voltage: ...
Mount, connect and you're ready to go. This is the new dimension for remote I/O mounted directly on the machine. Its credit card size design allows for mounting in the smallest areas. No space whatsoever is required in the control cabinet. IP67 protection ...
B&R Industrie-Elektronik
... SENSOR/ACTUATOR BOXES Sensor/actuator boxes, which are installed directly on machines or systems, are passive distribution systems for signal transmission that is rapid, cost-effective and, above all, cabinet-free. Thanks to the fully encapsulated ...
The I/O modules in the MX-System offer a wide choice for all signal types and directions. The MO1008-0000-1111, with eight digital inputs, acquires binary control signals from the process level and transfers them, with electrical isolation, to the controller. ...
Compact IO-Link master modules with eight multifunctional master ports are the most intelligent way to connect IO-Link devices. IP67 rated fieldbus modules are an important component in decentralized installations. They replace complexly wired and expensive ...
... The family of LioN-Power multiprotocol modules offer highly customizable features to deliver fieldbus-independent automation for the leading industrial Ethernet protocols. Replace modules faster by using the universal channels as digital input or digital ...
HIRSCHMANN
... Product information
The FBB-2DI1DO.R.xxx modules provide two digital inputs and one relay output. They are designed for decentralized switching tasks and are suitable for driving motorized fire dampers with end-switch feedback (OPEN/CLOSED) ...
Romutec Steuer- u. Regelsysteme GmbH
remote I/O boxes transmit various input and output signals between master devices such as PCs or PLCs and secondary devices including sensors and actuators. The IO-Link master type ADIO-ILM can exchange signals from secondary devices (IO-Link, standard ...
Autonics
The SPC-SDIO-S0808SPK is an intelligent distributed IO module designed by SonnePower for industrial and vehicle control applications. With 8 flexible I/O channels, a CAN bus interface supporting CANopen, and built-in voice alarm functionality, this smart ...
Hunan SonnePower International Co., Ltd.
TigoMaster 2TH is an industrial-grade IP67 IO-Link Wireless Master platform. It has two IO-Link Wireless tracks, supporting up to 16 IO-Link Wireless devices simultaneously. The TigoMaster 2TH includes interfaces to a variety of Industrial Ethernet protocols, ...
... GF 30 % Polyamid 8(12)~32 VDC -40°C … +80°C 35 Pin Tyco Seal USB2CAN Interface for Configuring Device Up to 26 Digital Inputs Up to 8 Frequency Inputs Up to 26 Analog Inputs Up to 10 Current Inputs Up to 6 Resistive/Temperature Sensor Inputs Up ...
Makersan
The TRS67 modules are EtherCAT slave devices, available in plastic or metal, waterproof and dustproof, compliant with the international standard IEC 60529. Depending on the model, each connector contains digital inputs or outputs and/or a connection to ...
... As a communication interface independent of the field bus, the sensors, actuators and I/O supporting the IO-Link protocol are IO-Link slave devices, which greatly improves the reliability of the devices. M12 series classification: - 16-channel digital ...
Sentinel Electronics
The 12 Inputs, 8 Analog and 1 Relay Outputs CAN I/O Module can extend machine control networks by adding I/O to the CAN bus. The controller features 1 Isolated CAN port for user-defined communications over the bus. It accepts up to 10 analog (0-5 V, 0-10 ...
The xtremeBLOCK CANopen module combines many different I/O signal configurations. It offers a total of 12 inputs, eight of which can be parameterized as analog. The remaining four digital inputs can also be configured as frequency inputs or counters. ...
Data Panel GmbH
... M12 interface、multi-protocol bus module、16DI/DO configurable、PNP、007E31 > Integrated four Ethernet interfaces: PROFINET, Ethernet/IP, CC-Link IEF Basic、Modbus TCP > 8 ports 16 signals > Input/output configurable > Protection level: IP67 (when installed ...
Fuyansheng Electronic (Fujian) Co., Ltd.
... Self-configuring Detailed channel-specific diagnostics Individually readable state of the outputs Inexpensive digital outputs ASi-5 self-configuring I/O module, in IP67, with 8 x M12 sockets, up to 16 digital inputs, up to 16 digital outputs, Y/mixed ...
Bihl+Wiedemann GmbH
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group