- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Low-pressure flow meter
Low-pressure flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Volumetric flow rate: 0 l/min - 800 l/min
Process temperature: -20 °C - 60 °C
Process pressure: 1.5 MPa
... made with Siargo's proprietary MEMS mass flow sensing technology and smart electronic circuitry. The meters directly measure mass flow with a very low pressure loss. ...
Volumetric flow rate: 0.1 m³/h - 160 m³/h
Process temperature: -20 °C - 65 °C
Process pressure: 0.2 MPa
... The meter is fully operated with battery. It is the 3rd generation of commercial gas meters for city gas applications. The meter is ATEX certified. It has also be used in the industrial burner fuel efficiency ...
Volumetric flow rate: 0 l/min - 4 l/min
Process temperature: -40 °C - 150 °C
Process pressure: 0 bar - 700 bar
... chemical resistance Rugged construction Individual calibration High viscosity capability Low pressure drop No flow conditioning required Compact meter assembly Hall, reed switch ...
Volumetric flow rate: 0.3 l/min - 50 l/min
Process temperature: -40 °C - 150 °C
Process pressure: 0 bar - 700 bar
... Excellent chemical resistance Rugged construction Individual calibration High viscosity options Low pressure drop No flow conditioning required Compact meter assembly Hall, reed ...
Volumetric flow rate: 0 l/min - 100 l/min
Process temperature: 60 °C
Process pressure: 10 bar
... Critical oil flow High viscosity liquids OEM equipment Hazardous areas Batching Features: Rugged construction High visibility Individual calibration High viscosity capability Low pressure ...
Volumetric flow rate: 0.1 l/min - 150 l/min
Process temperature: 0 °C - 80 °C
Process pressure: 0 bar - 200 bar
... the measuring unit wheels driven by the volumetric flow. The pulse evaluation is carried out using VSE evaluation electronics or any other evaluation device. The flow meters are ideal for low ...
Process temperature: -45 °C - 454 °C
Process pressure: 10, 6.9, 34, 70 bar
Precision: 0.5, 1.75 %
... thermal flow meters are your solution for large diameter pipe and air ducts applications. Applications Combustion air Stack gas flow Primary, secondary and overfire air flow Preheater ...
Volumetric flow rate: 0.2 l/min - 166,666.6667 l/min
Process temperature: -10 °C - 70 °C
Process pressure: 10 bar
... little differential pressure, Bronkhorst developed the LOW-ΔP- FLOW series mass flow meters and controllers. In these instruments, the flow ...
Process temperature: -40 °F - 900 °F
Process pressure: -6 psi - 6 psi
... flanged section of duct that contains an array of VAP Pitots along with straightening vanes that help channel air flow through the flow measurement section of the DSV. Below, you will find an overview of the DSV specifically ...
Volumetric flow rate: 0 l/min - 1,000 l/min
Process temperature: -10 °C - 60 °C
Process pressure: 45 psi
... MW– Low Pressure Drop Gas Mass Flow Meters High-accuracy, multivariate flow measurement with minimal system impact “Whisper” series mass flow meters ...
Volumetric flow rate: 0 l/min - 1,000 l/min
Process temperature: -10 °C - 60 °C
Process pressure: 45 psi
... MWB– Low Pressure Drop Portable Gas Mass Flow Meters Measure flow with minimal system impact, anywhere you need it “Whisper” series portable flow meters ...
Volumetric flow rate: 0.1 m³/h - 381,703.5 m³/h
Process temperature: -20 °C - 60 °C
Process pressure: 6 bar - 250 bar
... dirty liquid that is conductive or water-based, or for applications that require low- pressure drops and low maintenance. It applies to measure the volume flow of conductive medium including ...
Mass flow rate: 360 kg/h - 2,000,000 kg/h
Process temperature: -70 °C - 300 °C
Process pressure: 86,000 Pa - 106,000 Pa
... Coriolis mass flow meter (also known as Coriolis mass flow meter) is a kind of mass flow meter with high measurement accuracy. The principle is based ...
Process temperature: -20 °C - 50 °C
... MultiCon = Meter + Controller + Recorder + HMI + SCADA in one package stable firmware based on Linux 13 available input/output blocks colour LCD display 3,5" TFT, with touchscreen recording data with maximum speed 10Hz (ten samples ...
Mass flow rate: 0 kg/h - 0.16 kg/h
Volumetric flow rate: 0 m³/s - 0 m³/s
Process temperature: 0 °C - 50 °C
... parallax error Virtually independent of temperature and pressure variations Low pressure drop Wide flow ranges Fast response Electronic output: Configurable password protection Alarm ...
Mass Flow ONLINE BV
Process temperature: -20 °C - 80 °C
Process pressure: 100 bar
... sensor flow, Water, Calorimetric, Ø40mm 73long, G1/4 inch, 24V DC, PNP NO (NO), Plug-in connection M12 4pin, V4A, Pressure resistance 100bar, Manual adjustment including 1x Screwdriver Flow sensors ...
Volumetric flow rate: 30 l/h - 7,500 l/h
Process temperature: 0 °C - 100 °C
Process pressure: 0 bar - 12 bar
... of handling flow rates as low as 50cc/min air, while the complete range of 12 models provide high accuracy for most low- flow applications. These models all feature flow ...
... the inlet contour matches that of the ISA 1932 flow nozzle. The major advantage of the Venturi over orifice plates and flow nozzles is in the area of pressure recovery. Typically, unrecovered pressure ...
Process temperature: 20, 60 °C
... The MPB Series FA20 Flow Alarm will give a switched output at a predetermined flow i.e. 1 L/min. The FA20 is a low- pressure drop device and can be positioned either in-line or on a ...
MPB INDUSTRIES
Volumetric flow rate: 0 m³/h - 200,000 m³/h
Process temperature: -20 °C - 50 °C
Process pressure: 2,000 Pa
... measurement probe. Usage The DPT- Flow-Batt is an on-site display designed for air handling units to measure the air flow on centrifugal fans. The DPT- Flow-Batt can also be used in the duct system as ...
Process temperature: -20 °C - 40 °C
Process pressure: 10 bar - 400 bar
... The Flow metering device is designed to volumetrically monitor small flow rates on low pressure lubrication systems. Its operation is based on the progressive system operating concept. The ...
Volumetric flow rate: 200 l/min
Process temperature: -20 °C - 80 °C
Process pressure: 1.3 bar
... SFM3000 is a digital flow meter especially suitable for high-volume applications. The design of the flow channel results in very low pressure drop through the sensor ...
Sensirion
Volumetric flow rate: 0.8 m³/h - 1,600 m³/h
Process temperature: -20 °C - 300 °C
Process pressure: 16, 40, 10 bar
... treatment & distribution, Pharmaceutical, chemical and paper industry, heating and cooling circuits, swimming pools, fire protection systems, automotive industry (cutting oil, paint lines and refrigeration systems), power ...
TECFLUID
... rapid, accurate and repeatable quality control.
Main features
- Very high-resolution differential pressure sensors for stable measurement and reduced thermal and pneumatic disturbance effects.
- Extremely
Process pressure: 2 MPa
... the meter can either be a spool piece or a skid mounted design. Working Principle This compact unit is composed of a Venturi flow meter and dual energy gamma meter. Total Flow ...
Haimo Technologies Group Corp.
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
Precision: 2 %
... . The VPFlowScope M can be installed under pressure and measures (bi-directional) flow, pressure, temperature, and total flow simultaneously. The flow meter ...
VPInstruments
Volumetric flow rate: 1,000 m³/h
Process temperature: -40 °C - 70 °C
Process pressure: 21 bar
... aluminum case is designed for operating pressures up to 20 bar, with a safety factor of 4. The geometry of the pistons and the position of bearings and shafts make the meter less sensitive to overloads and pressure ...
Volumetric flow rate: 0.1 l/min - 70 l/min
Process temperature: 80 °C
Process pressure: 10, 20 bar
... oval gear flow meter 2950 serves most industrial applications where oil is used as media. It is a dependable flow meter especially designed for lubrication oil flow measurement ...
Kytola Instruments Oy
Process temperature: -20 °C - 85 °C
Precision: 2 %
... Features of Clamp-on, Ultrasonic Flow Meter Easy to install Maintenance-free Suitable for a variety of pipe diameter requirements Quick Installation Steps of Clamp-on, Ultrasonic Flow ...
Volumetric flow rate: 0.1 m³/h - 800 m³/h
Process temperature: -20 °C - 120 °C
Precision: 1, 0.5 %
... flowmeter, as fluid flows through turbine rotor and drives it to rotate, the rotating rotor periodically cuts magnetic field line to generate electric pulse signal, which can be transmitted to output and transferred to the meter ...
ALIA GROUP INC
Volumetric flow rate: 0.4 l/min - 100 l/min
Process temperature: 150 °C
Process pressure: 100 bar
... particles in the flow. Typical applications The flowmeters type DK04 are applied to monitor and supervise water or liquids similar to water up to a viscosity of 20 cSt. All applications where a high reproducibility ...
Process temperature: -40 °C - 350 °C
Process pressure: 1.6 MPa - 4 MPa
Precision: 1, 1.5 %
... series Vortex Flow Meter can be used to detect and measure the flow of all kinds of gas, fluid and steam. 1% accuracy stainless steel steam gas liquid fluid vortex flow meter,China ...
Process pressure: 3,000, 4,000 psi
... flowgauges and regulators contain the following: • Machined brass body • Mechanical stem type seat and porous metal inlet filter (except CO2 models) • Fine mesh filter screen between inlet and body (except for CO2 models) • Pressure ...
Volumetric flow rate: 9 us gal/min - 180 us gal/min
Process temperature: -4 °F - 140 °F
Process pressure: 145 psi
... Switches, and Integral Totalizers or Batch Controllers Highlights: No Moving Parts in the Flow Body Low Pressure Loss Universal Mounting High Quality at a Low Price ...
Process temperature: 50 °C - 500 °C
Process pressure: 1.6, 2.5, 4, 6.4 MPa
Precision: 1, 0.5, 2.5 %
... and integrated temperature and pressure compensation. The basic type measures the flow signal of a single working condition. The integrated temperature and pressure compensation can measure temperature, ...
... series gas turbine flow meter is equipped with mechanical counter it’s a kind of meter don’t run slowly with high flow measurement accuracystrong anti-magnetic attack ...
Volumetric flow rate: 2 l/min - 2,250 l/min
Process temperature: -40 °C - 230 °C
Process pressure: 10 bar - 16 bar
... has been thought of in the manufacture of the Metri Hygienic Turbine Flow Meter; especially cleaning and maintenance. The bearings of the meter can be easily cleaned by using low pressure ...
Volumetric flow rate: 25 l/min - 3,000 l/min
Process pressure: 10 bar
Repeatibility: 0.05 %
... adjustment of the meter High accuracy and repeatability over the widest range of flow; Superior accuracy at constant flow Low maintenance, no metal-to-metal contact in measuring chamber, ...
Process pressure: 2.5, 1.6, 4, 1 MPa
Precision: 1.5 %
Repeatibility: 0.2 %
... with low pressure loss, low initiating flow and wider measurement range. The display of gas turbine flow meter support to rotate 350°, easy to read data ...
Process temperature: -40 °C - 350 °C
Process pressure: 0 bar - 63 bar
Precision: 1, 0.75 %
... situations, but the vortex flow meter has a wide range and a minimal pressure drop, making it a popular choice among flow professionals. Vortex Flow Meter ...
Process temperature: -40 °C - 150 °C
Process pressure: 10 bar
... additional temperature or pressure compensation in thermal mass flow meter. This meter is also used for compressed air flow measurement. Benefits: Good level of accuracy ...
Process Control Devices
Volumetric flow rate: 6 m³/h - 6,500 m³/h
... has stable and excellent low- pressure and high- pressure metering performance, explosion-proof design, and the rear meter head cover is hinged for easy maintenance. It is especially suitable ...
... • Flow rate measurement is independent of the flow profile • Pulsed coil excitation to obtain a minimum zero drift • Readings are independent of density, temperature, viscosity and pressure • Absence ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.