- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Remote flow meter
Remote flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Process temperature: -50 °C - 180 °C
Process pressure: 0 bar - 100 bar
... 5400 is a Coriolis mass flowmeter for standard process applications with gases and liquids. The twin semi-bent tube sensor provides direct mass flow, density and temperature measurement ...
Process temperature: -40 °C - 140 °C
Process pressure: 0 bar - 5 bar
Precision: 0.5 %
... Overview
The OPTIFLUX 6000 is an electromagnetic
flowmeter (EMF) designed for hygienic applications in the food and beverage industry. Certified to 3A and EHEDG, it provides industry-specific insertion lengths to meet hygienic ...
Volumetric flow rate: 0.2 m³/h - 970 m³/h
Process temperature: -40 °C - 400 °C
Process pressure: 0 bar - 175 bar
... vortex flow meter that saves you time and costs by measuring flow, temperature, pressure, density, energy and mass in a single meter, with no need to recalibrate for ...
Volumetric flow rate: 5.2 m³/h - 8,537 m³/h
Process temperature: -40 °C - 260 °C
Process pressure: 0 bar - 175 bar
... MV82 insertion mass flow meter is a multivariable vortex flow meter for measuring volumetric flow, temperature, pressure, density and mass flow. ...
Process temperature: -20 °C - 60 °C
Precision: 0.4 %
Repeatibility: 0.1 %
... ELECTROMAGNETIC FLOWMETER
HIGH-PRECISION FLOW MEASUREMENT FOR WATER NETWORKS WITHOUT EXTERNAL POWER SUPPLY
The M5000 self-powered electromagnetic
flowmeter is designed for accurate ...
Process temperature: -20 °C - 60 °C
Repeatibility: 0.1 %
... ATEX ELECTROMAGNETIC FLOWMETER M3000/4000
RELIABLE FLOW MEASUREMENT FOR HAZARDOUS AREAS
The Fuji Electric ATEX electromagnetic
flowmeter M3000/4000 is designed ...
Process temperature: -50 °C - 250 °C
Process pressure: 150, 300 psi
Precision: 1, 0.75, 2 %
... The Rosemount 8600 Utility Vortex flow meter is optimized for general purpose flow metering and utility applications including clean fluids and steam flow. The 8600 Utility Vortex meter ...
Volumetric flow rate: 0.5 l/min - 75,000 l/min
Process temperature: -15 °C - 100 °C
Process pressure: 0 bar - 10 bar
... The paddle wheel flowmeter for continuous flow measurement is especially designed for use in neutral, slightly aggressive, solid free liquids. The Bürkert designed fitting system ensures simple installation of the devices ...
Process temperature: -25 °C - 130 °C
Process pressure: 10, 40 bar
... Integral mount design or remote mount design – With or without local LCD display – Universal wide range power supply – 1 analog output, 2 digital outputs Robust construction for rough environmental conditions – Hermetically sealed ...
Process temperature: -15 °C - 80 °C
Precision: 0.25, 2 %
Repeatibility: 0.1 %
... portable area velocity meter that measures flow using a submersible ultrasonic sensor. The unit is designed for flow surveys in open channels, partially-full sewer pipes, and surcharged pipes – making ...
Pulsar Measurement
Process temperature: 0 °C - 80 °C
Process pressure: 0 psi - 500 psi
Precision: 1.5 %
... aluminum Overview The TopTrak® 800 series provides an economical OEM gas mass flow meter in your choice of nylon, aluminum or stainless steel. Direct mass flow rate measurement with the nylon ...
Sierra Instruments
Process temperature: -20 °C - 150 °C
Process pressure: 40, 10, 16, 6 bar
Precision: 0.25, 0.5 %
... lengths. Therefore, the flowmeter provides very accurate measurements - even over a large area. With electromagnetic flowmeters from MJK, you are guaranteed stable, accurate measurements for years. If you want to know ...
Mass flow rate: 0 kg/h - 5 kg/h
Volumetric flow rate: 2 l/min - 1,500 l/min
Process temperature: -10 °C - 55 °C
... category
Mass
flow sensing products: mass
flow
meters
MF3000
The MF3000 series mass
flow
meters are designed for general-purpose gas metering, ...
Volumetric flow rate: 0 l/min - 800 l/min
Process temperature: -10 °C - 55 °C
Process pressure: 1 MPa
... series mass flow meters are designed for general purpose flow metering and control applications and are made with Siargo's proprietary MEMS mass flow sensing technology and smart electronic ...
... Product description
The F175 is a pump/level controller offering
continuous level monitoring and dual open-channel
flow measurement. It displays level/height or volume with a dedicated bargraph and supports ...
... always available for ADCP measurements. The motorised Q-Boat 1250 with remote control function bridges this gap and places the survey team in the position to carry out highly efficient flow measurements at almost any ...
... always available for ADCP measurements. The motorised Q-Boat with remote control function bridges this gap and places the survey team in the position to carry out highly efficient flow measurements at almost any location. High-Performance: Two ...
Process temperature: -20 °C - 70 °C
Precision: 5 %
... NivuFlow 7550 is a hybrid flow measurement system for part‑filled pipes, open channels and surface waters. It combines contactless radar surface velocity measurement with an ultrasonic sideways profile scanner to deliver reliable flow ...
Process temperature: -20 °C - 70 °C
... velocity paths. The NivuFlow 650 operates over the full bi-directional flow range without causing obstruction or head loss where the large array of NIVUS transducer models permits flow measurement across the widest ...
Process pressure: 0.01 bar - 1.6 bar
Precision: 1.5, 0.5 %
Repeatibility: 0.5 %
... vacuum pumps. This inline flow meter measures the actual flow and absolute pressure on the low pressure side of vacuum pumps. Convenient installation, great flexibility, and can be installed anywhere Inline ...
Process temperature: -20 °C - 60 °C
Process pressure: 0.6, 1.6, 4 MPa
Precision: 0.5, 0.2 %
... measuring instantaneous pulsating flow with good linearity.
Shanghai LEEG Instruments Co.,Ltd.
Process temperature: -20 °C - 60 °C
Process pressure: 1.6 MPa
Precision: 2.5 %
... electromagnetic flow meter measures conductive liquid flow using an insertion probe suitable for large-diameter pipelines. The design supports hot tapping and pressurized installation, allowing installation ...
Shanghai LEEG Instruments Co.,Ltd.
Process temperature: -40 °C - 60 °C
Process pressure: 4, 1.6, 1, 0.6 MPa
Precision: 0.2, 0.5 %
... cumulative flow during power-off.
Shanghai LEEG Instruments Co.,Ltd.
Volumetric flow rate: 0 m³/h - 120 m³/h
Process temperature: -30 °C - 180 °C
Process pressure: 16 bar
... external (sanitary) meters and optional analogue and RS485 output for measuring cold water or pre-programming the value for open systems. Description The energy meter and ultrasonic flow rate IFX-M4-04, ...
Process temperature: 10 °C - 45 °C
Process pressure: -1 bar - 20 bar
Precision: 2.5 %
...
The ATEQ MF570 is a differential micro
flow tester combining fast cycle times with high-accuracy leak measurement. It uses differential pressure drop and stable
flow measurement via a laminar
flow ...
Process temperature: -35 °C - 60 °C
Precision: 1 %
Repeatibility: 0.1 %
... and high flow velocities - Non-contact radar measuring technology - No threat from debris or driftwood - Calculation of discharge with known water level and cross section profile - Easy operator controls and handling - ...
Process temperature: -18 °C - 121 °C
Process pressure: 34, 10 bar
Precision: 0.5, 1, 2 %
... compact, low cost solution for accurate, repeatable flow measurement of biogas, digester gas, landfill gas, methane and natural gas as well as air, compressed air or nitrogen. This insertion-style flow meter ...
Volumetric flow rate: 5.13 m³/h - 951.57 m³/h
Process temperature: -18 °C - 121 °C
Process pressure: 16.5, 41 bar
... The ST75 Series thermal flow meters are a compact, low cost solution for accurate, repeatable direct mass flow measurement of air and gases. These in-line (spool-piece) style flow meters ...
Volumetric flow rate: 0 m³/h - 244,290.2 m³/h
Process temperature: -20 °C - 120 °C
Process pressure: 1.6, 1, 0.6 MPa
... electromagnetic flowmeter is used to measure the volume flow of conductive liquids and slurries in closed pipes. The measuring flow rate is not affected by density, viscosity, temperature and pressure ...
... The SeFlow 400 is Sewerin’s single channel portable flowmeter for applications in the municipal water and wastewater sector offering long term stable and precise bidirectional flow measurements in remote ...
Volumetric flow rate: 0.02 m³/h - 565.2 m³/h
Process temperature: 0 °C - 110 °C
Precision: 2 %
... liquid flow meter engineered for small pipe diameters and easy integration into equipment. The sensors mount externally with a size-matched bracket: no pipe cutting, drilling or process contact is required. Configurations ...
Process temperature: -30 °C - 80 °C
Precision: 2, 1 %
... 60GHz radar flow meter is developed based on PCR radar measurement technology. The flowmeter is made of pure aluminum material and wireless transmission (4G and Nb-IoT) function. It can not only be used ...
Holykell
Volumetric flow rate: 0.1 m³/h - 381,703.5 m³/h
Process temperature: -20 °C - 60 °C
Process pressure: 6 bar - 250 bar
... Electromagnetic flow meters do not have any moving parts and are often chosen because they are less obstructed, cost-effective, bi-directional, and provide highly accurate volume flow measurements. They ...
Holykell
Process temperature: 60 °C
Precision: 1, 1.5 %
... accumulated flow display 05Forward and reverse two-way flow measurement 06GSM and GPRS wireless data remote transmission function(optional) DN200-DN6000mm,rectangular pipe: width ≤6m Measurement ...
Holykell
Process temperature: -40 °C - 350 °C
... Overview
The YFVW300D is a vortex
flow
meter based on the Kármán vortex street principle for non‑contact measurement of steam, gases and low‑viscosity liquids. It integrates industrial wireless communication ...
Xi'an Yunyi Instrument Co., Ltd.
Process temperature: -40 °C - 350 °C
... Overview
The YFVW300A wireless vortex
flow
meter delivers non-contact
flow measurement for steam, industrial gases and low‑viscosity liquids using the Karman vortex principle combined with LoRaWAN ...
Xi'an Yunyi Instrument Co., Ltd.
Process temperature: -40 °C - 350 °C
... Overview
The YFVW300C wireless vortex
flow
meter applies the Kármán vortex street principle with industrial wireless communication (NB‑IoT and LoRaWAN) to perform non‑contact
flow measurement ...
Xi'an Yunyi Instrument Co., Ltd.
Process temperature: -40 °C - 130 °C
Precision: 1 %
... battery that provides up to 16 hours of
continuous operation, all stored in a sturdy aluminum carrying case.
Main Technical Specifications
Accuracy: ±1% of the measured value
Flow Range: ...
ASIT ITALIA
Volumetric flow rate: 0.1 m³/h - 61,072 m³/h
Process temperature: -25 °C - 180 °C
Process pressure: 40 bar
... The AI.MF Series electromagnetic flow meter from ASIT Italia is the ultimate professional instrument for the precise measurement of conductive liquids. Thanks to the absence of moving parts, it guarantees ...
ASIT ITALIA
Volumetric flow rate: 5 m³/h - 6,000 m³/h
Process temperature: 250 °C
Precision: 1 %
... AI.VFM Series flow meter is the ultimate instrument for precise measurement of gases, steam, and liquids. Utilizing the Karman vortex physics principle, it offers extremely reliable volumetric and mass ...
ASIT ITALIA
Volumetric flow rate: 0.01 us gal/min - 53,779 us gal/min
Process temperature: 0 °F - 248 °F
Process pressure: 0 psi - 150 psi
... Electromagnetic flow meter is virtually unaffected by density, temperature, pressure and viscosity changes, making it an accurate and reliable long-term metering solution. Innovative Design. Enhanced Performance. The ...
Badger Meter
Mass flow rate: 0 kg/min - 200 kg/min
Process temperature: -196 °C - 400 °C
Process pressure: 0 bar - 882 bar
... The RHM 15 is an all-purpose meter suitable for liquid processing plants. A wide application flow range capability allows for commonality of installation across numerous lines – a real benefit to owners and operators. Materials: ...
Rheonik Messtechnik GmbH
Volumetric flow rate: 0.5 l/min - 1,750 l/min
Process temperature: 0 °C - 1,000 °C
Process pressure: 0 bar - 10 bar
... The Series 1750 range of Variable Area Flowmeters are ideal for providing instantaneous flow rate measurement for most process gases and liquids. The standard models are suitable for flows up to 50 lit/min ...
Volumetric flow rate: 40 l/min
Process temperature: 5 °C - 50 °C
Process pressure: 0 bar - 10 bar
... response for time-critical flow processes. The faster your thermal mass flow controllers and meters respond, the more efficient and productive your processes can be. That’s the key advantage of the ...
Brooks Instrument
... hydroengineering applications, was developed for ultrasonic flow measurements in filled and partially filled pipes and open channels. Whether for penstock monitoring, turbine and pump efficiency measurements or flow measurements ...
Volumetric flow rate: 0.8 m³/h - 1,600 m³/h
Process temperature: -20 °C - 300 °C
Process pressure: 16, 40, 10 bar
... safe or hazardous area (Ex ia IIC T4 or T6 protection, ATEX certified) HART ™ protocol on request Local volume totalizer. Remote volume totalizer by means of pulse output (not available for Ex transmitters) ...
Process temperature: -25 °C - 250 °C
Process pressure: 1 MPa - 4 MPa
Precision: 0.5, 1 %
... also has the accumulative pulse equivalent output. It has the measurement, display , remote data transmission, wireless remote control, alarm, remote wireless meter reading system (computer ...
Process temperature: 0 °C - 50 °C
Process pressure: 0.2 bar - 11 bar
Precision: 1, 2, 3 %
... auto/manual/ remote reset, delay and alarm duration MEMS Sensor The MEMS semiconductor chip is the centerpiece of the thermal mass flow meter. Analog-digital conversion takes place in the sensor Totalizer In ...
Vögtlin Instruments GmbH – Gas Flow Technology
Process temperature: -10 °C - 120 °C
Process pressure: 1.6, 0.6 MPa
Precision: 0.5 %
... proportion to flow speed v: Where: E-Induced electromotive force K- Meter constant B-Magnetic induction density V-Average flow speed in cross-section of measuring tube D-Inner diameter of measuring ...
Supmea Automation
... displacement gear meters work in bi-directional flow applications and are unaffected by changing viscosities. The Gear Meters offer multiple output options including pulse, analog, or Modbus to deliver ...
AW-Lake Company
Process pressure: 2 MPa
... the meter can either be a spool piece or a skid mounted design. Working Principle This compact unit is composed of a Venturi flow meter and dual energy gamma meter. Total Flow ...
Haimo Technologies Group Corp.
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
Precision: 2 %
... VPFlowScope M can be installed under pressure and measures (bi-directional) flow, pressure, temperature, and total flow simultaneously. The flow meter is an all-in-one and versatile flow ...
Volumetric flow rate: 0 l/min - 30,000 l/min
Process temperature: 180 °C
Process pressure: 16 bar
... CONTOIL® flowmeters work according to the volumetric principle of rotary piston meters (volumetric meters). The main features of this measuring principle are large measuring ranges, high accuracy and ...
Riels Instruments
Process temperature: 80, 120 °C
Process pressure: 30, 20 bar
Precision: 5 %
... The variable area flow meter K Smart represents a new generation of flow meters for industrial flow measurement and monitoring of air and other gas flows. ...
Kytola Instruments Oy
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.