... because when stopping a machine, the actuator that is connected to machine guard is detached from head switch. Intended for heavy loaded industrial machines with fast rundown time. The device comes with ...
Telemecanique Sensors

Coded magnetic switches are available in a variety of types. They offer amazing protection against tampering. Made of sturdy plastic, the switches are available with 9m, 6m and 3m cable or connector versions. Switching ...

... dirt and are more accommodating to misalignment than mechanical switches Compact size makes it possible to conceal the switch Three housing styles are available for flat or 30 mm barrel-style mounting All ...

Primary current: 100 mA
Voltage: 30 V
... established non-contact door monitoring RE1 magnetic safety switches are equipped with either complementary NC/NO contacts or equivalent N/O contacts which are addressed directly with coded magnetic ...
SICK

Voltage: 250 V
Operating temperature: 0 °C - 55 °C
... with more than one connected read head Notice: At low approach speeds in the z direction, the time offset when switching the reed contacts must not be more than 0.6 ms.
EUCHNER GmbH + Co. KG

Primary current: 8 mA - 500 mA
Voltage: 26, 2, 24 V
Read heads CMS, design A - with NO contact combinations, PVC • In combination with evaluation unit CMS-E-AR • Cube-shaped version, 88 x 25 mm • NO contacts wired in parallel • Connecting cable • Cable type: PVC
EUCHNER GmbH + Co. KG

Primary current: 0 A - 0.04 A
Voltage: 20 V - 35 V
Read heads CMS with Hall sensors - design A • In combination with evaluation units CMS-E-ER/CMS-E-FR • Cube-shaped version, 87.5 x 25 mm • 1 LED • Hard-wired encapsulated cable made of PVC, 3 m
EUCHNER GmbH + Co. KG

A safety gate monitoring module, which is manufactured by Dold, is a safety device which regulates the position of mobile safety devices via interrogation of safety switches that are operated via opening and closing of a safety device.

Magnetic Safety Sensors with coded magnets They can be connected with: the programmable safety controller Mosaic, with which they are certified to reach safety level PLe / SIL3 (up to 4 sensors with M1) the dedicated ...

Primary current: 2 A
Voltage: 24 V - 48 V
Operating temperature: -25 °C - 60 °C
Safety switch with magnetic hold 4 Kgs Position control for doors / casings on dangerous machinery with magnetic holding devices 40N integrated stainless steel magnetic ...
COMITRONIC - BTI

Operating temperature: -40 °C - 125 °C
Safety switch with magnetic hold Position control for doors / casings on dangerous machinery with magnetic holding devices 20 N integrated handle magnetic door holding High ...
COMITRONIC - BTI

Primary current: 250 mA
Voltage: 24 V
Operating temperature: -25 °C - 70 °C
Safety switch with magnetic hold 4 Kgs Position control for doors / casings on dangerous machinery with magnetic holding devices • 40N integrated stainless steel magnetic ...
COMITRONIC - BTI

Primary current: 0.3 A - 21.5 A
Voltage: 400 V
... switches can be supplied in 10 setting ranges from 0.3 to 16 amps. In addition to thermal triggering, the switch can also be supplied with quick KA magnetic triggering or UA low-voltage triggering. Operation ...

Primary current: 0.3 A
Voltage: 24 V
Operating temperature: -10 °C - 55 °C
... : PRE-WIRED CABLE LENGTH : 3, 6 OR 10 METRE CODING : TAMPER RESISTANT INDICATION : 1 X VOLT FREE CONTACT DIMENSIONS OF SWITCH (MM) : 52 X 28 X 14MM DIMENSIONS OF ACTUATOR (MM) : 52 X 28 X 14MM CONSTRUCTION : RED ...
Mechan Controls

Primary current: 8, 5 A
Voltage: 28 V
Operating temperature: -40 °C - 85 °C
This precision trigger switch offers two levels of operation with positive detent between levels. The switch has an actuating force of 3.0 lbs. to make the first pole, and an additional 5.0 lbs. to actuate ...

Voltage: 24, 12 V
... shutdown or shutdown only. For distributor ignition engines, the magnetic switch opens the distributor coil circuit to cause shutdown. For magneto or CD ignitions the magnetic switch ...

Primary current: 0.4 A
Voltage: 60 V
... range of ATEX sensors. celduc® relais has EC-type examination certificate Nr. INERIS 04ATEX0105. Groupe II : Open-air industry (other than mines) with possible inflammable dust. Type of devices : 1 for zone 0 ...

Primary current: 0 A - 0.5 A
Voltage: 0 V - 200 V
... meter: activating magnet mounts to propeller blade. Valve-position indicator: activating magnet, mounted on valve, triggers switch. Mechanical-movement monitoring; activating magnet mounts on moving machinery.

Primary current: 0 A - 0.5 A
Voltage: 0 V - 100 V
MCS-100 is an alarm and security switch characterized as either normally open or closed switch. It allows various switching distance with a 10VA maximum switching capacity. This switch ...
The Comus Group

... safety switches. Unlike most systems that require 6 or 7 connections to each switch to achieve CAT 3 and above, the ISIS requires only a simple 2-wire connection. Each switch is monitored individually ...

Primary current: 0.2 A
Voltage: 24 V - 250 V
Wide 10mm sensing LED indication Up to PLe/Cat.4 with ZANDER safety relay High tolerance to misalignment 2 NC/1NO transistor circuits Protection category IP67
Zander GmbH & Co. KG, Hermann

Voltage: 4 V
Window contact for status monitoring of windows and doors. Energy generation by solar power. Battery-free transfer of the opening state of doors and windows.

Primary current: 1 A
LPR magnetic non contact Euromag power series switches are suitable for all industrial safety relay applications. They conform to all Europeans standards. Packaged in slim and durable polyester material, ...
Idem Safety Switches

Primary current: 25 A - 450 A
Voltage: 690 V
... Finger-proof) for contact prevention of magnetic contact. It is very convenient to remove by using a modularized auxiliary contact. - Removable with DIN-Rail installation structure. - It is possible to remove the ...

... Proximity Sensors Capacitive Sensors Magnetic Sensors Industrial Switches Limit Switches Foot Switches Cable Pull Switches Safety Technology Products Safety Interlocks Cable Pull Switches Coded ...

• For replacing and changing low-voltage high performance fuses (low-voltage fuses) • With contact knives according to DIN 43620 part 1 of sizes 00-3 for nominal voltage up to 600V ac

Voltage: 3 V - 30 V
Magnetic switches are accessories that allow to identify the position of the piston inside the cylinder. They have different shapes, oval, round or “T”, and they are available in two versions, REED or HALL.

Voltage: 24, 220 V
... Flap-11 Magnetic Level Indicator for remote alarm as well. The magnetic float in the chamber rises or falls with the up and down of the liquid level in the vessel. When the magnetic ...

... diagnostics functions Optional magnetic catch (18N) prevents unintentional opening Can be adjusted quickly through a larger switching displacement than mechanical switches and boundary detection by LED indication on ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining