- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Maintenance-free level switch
Maintenance-free level switches
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Process temperature: -52 °C - 240 °C
Process pressure: -1 bar - 37 bar
... description
The JUMO NESOS R04 LS float
switch in curved version is designed to
switch alarms, pumps, signal lamps, valves and horns via a contact-protection relay. The device is suitable for
liquid ...
Process temperature: -196 °C - 350 °C
Process pressure: 0 bar - 40 bar
... available, when the filling level continues to rise above or drop below the switch point. The float switch is simple to mount and maintenance- free, so the costs of ...
Process temperature: -40 °C - 150 °C
Process pressure: -1 bar - 64 bar
... mounting position, level changes can be detected very accurately. The respective switch point can be changed via a pipe extension. The TLS-C vibrating level switch is specially designed ...
Process temperature: -40 °C - 120 °C
Process pressure: 0 bar - 5 bar
... Level monitoring and level indication of liquids Level detection for almost all liquid media Pump and level control Alarm signals ...
Process temperature: -50 °C - 130 °C
Process pressure: 0 bar - 63 bar
... controller is required for operation. The multiple rod electrode EL 3 is a universal level switch for conductive liquids. The instrument is ideal as overfill and dry run protection or pump control in ...
Process temperature: -40 °C - 80 °C
Process pressure: 0 bar - 4 bar
... is the receiving unit of the microwave barrier for level detection of bulk solids and liquids. Typical applications are the detection of bulk solids in silos, bunkers and crushers as well as of liquids in tubes and vessels. ...
Process temperature: -40 °C - 80 °C
Process pressure: 0 bar - 4 bar
... guarantees continuous, wear and maintenance free operation. Detached version for use in poorly accessible or dangerous mounting locations. The VEGAMIP R62 is the receiving unit of the microwave barrier in separate version ...
Process temperature: -40 °C - 150 °C
Process pressure: -1 bar - 40 bar
... VIBRATION LEVEL SWITCH - LIQUID FORK The compact and robust solution for safe level monitoring for all types of liquids. Versatile, extensive configuration options, corrosion-resistant ...
UWT GmbH
Process temperature: -40 °C - 1,100 °C
Process pressure: 0.9 bar - 10 bar
... ROTONIVO® - PROVEN ALLROUNDER FOR POINT LEVEL MEASUREMENT The Rotonivo® rotary paddle level switch from UWT operates reliably and maintenance- free and offers a compatible ...
UWT GmbH
Process temperature: -40 °C - 80 °C
Process pressure: 0 bar - 0.8 bar
... ROTONIVO® - PROVEN ALLROUNDER FOR POINT LEVEL MEASUREMENT The Rotonivo® rotary paddle level switch from UWT operates reliably and maintenance- free and offers a compatible ...
UWT GmbH
Process temperature: -50 °C - 250 °C
Process pressure: -1 bar - 16 bar
... changes of product properties ( maintenance- free) * Optional version to detect solids in water * Remote housing up to 25 m / 82 ft * Silos with light bulk goods * Limit and overfill detection * ...
Process temperature: -20 °C - 200 °C
Process pressure: -1 bar - 16 bar
... Capacitance level switch OPTISWITCH 6500 C|6600 C Capacitance level switch for advanced hygienic applications* Point level detection of liquids, liquid-liquid interface ...
Process temperature: -20 °C - 50 °C
... reactor systems. Sludge blanket level measurement works by measuring the distance between the sludge blanket surface and the water level. Once the sludge has reached the required density, the accompanying ...
Process temperature: -40 °C - 150 °C
Process pressure: 0 bar - 25 bar
... Conductive limit switch for liquids for front-flush mounting Compact level switch with partial PTFE insulation Application area For front-flush installation. The instrument is ...
VEGA TECHNIQUE
Process temperature: -50 °C - 130 °C
Process pressure: 0 bar - 63 bar
... controller is required for operation. The multiple rod electrode EL 3 is a universal level switch for conductive liquids. The instrument is ideal as overfill and dry run protection or pump control ...
VEGA TECHNIQUE
Process temperature: -40 °C - 80 °C
Process pressure: 0 bar - 4 bar
... Microwave emitter for level detection of bulk solids and liquids Microwave transmitter Application area Transmitting unit of the microwave barrier. To be used with a receiving unit of type VEGAMIP R61 or 62. The ...
VEGA TECHNIQUE
... capacitance level switches can’t be used) ; when material moisture content changes easily; low viscosity liquids; there is a combination of differing materials in the container/tank. The Vibrating probe provides a reliable & maintenance- free ...
Process temperature: -40 °C - 85 °C
Process pressure: 1,000 psi
... IntelliPoint the most versatile RF level switch on the market. Key Features • AutoVerify and Certify test features for critical point level and overfill protection applications • Cote-Shield circuitry ...
AMETEK Drexelbrook
Process temperature: -40 °C - 85 °C
Process pressure: 1,000 psi
... ultimate in level switch integrity and level sensing elements for a wide variety of temperatures, pressures, and materials. The Safety IntelliPoint is our BEST and most versatile ...
AMETEK Drexelbrook
... The SIL IntelliPoint capacitance probe level switch is specifically designed for Floating Roof Tanks (internal and external roofs) with a flexible brass level sensing probe. The level ...
AMETEK Drexelbrook
Process temperature: -25 °C - 70 °C
Process pressure: 16 bar
... Optical filling level monitor with resistant glass tip for the reliable monitoring of the maximum or minimum filling level of fluids Detects fluids with a very low DK values, such as oil Resistant to detergents, ...
Process temperature: -20 °C - 50 °C
... flush probe represents a low profile RF capacitance plug switch level monitor. The unit is specifically designed for used in tight fitting applications to detect levels of liquids, powders and free ...
Process temperature: 0 °C - 250 °C
Process pressure: 0 bar - 250 bar
... mechanism. Bellow material Perbunan Safety Integrity Level (SIL) SIL 1 (Type AA 01 051: SIL 2) Approvals ABS, BV, ClassNK, DNV-GL, LR, RINA, RMRS Bellow material Silicon Safety Integrity ...
Trimod'Besta
Process temperature: 0 °C - 330 °C
Process pressure: 40 bar
... Microswitch SPDT with silver contacts Switch rating 250 VAC, 5 A / 30 VDC, 5 A Enclosure IP65 Weight 5.4 kg Overall length (tank) 226 mm Safety Integrity Level (SIL) SIL 1 (Type AA 22C 04: ...
Trimod'Besta
Process temperature: 0 °C - 400 °C
Process pressure: 100 bar
... résistant die cast aluminium smooth raised face, form B2 Switch element - Microswitch SPDT with silver contacts Switch rating - 250 VAC, 5 A/30 VDC, 5 A Weight - approx. 9.6 kg Safety Integrity ...
Trimod'Besta
Process temperature: -40 °C - 85 °C
... diaphragm switch is a pressure switch for high or low- level alerts in bins containing non-hazardous, free-flowing dry materials. It is mounted internally. Point level ...
BinMaster
Process temperature: -40 °C - 150 °C
... design WHG approval Maintenance- free High resistance to chemicals Versatile process connections Commissioning without calibration Application Suitable for detecting limit levels ...
Process temperature: -40 °C - 230 °C
Process pressure: -1 bar - 64 bar
... Systems with SIL2/SIL3 functional safety requirements. 2. It can be used in aseptic applications in the life science industry. 3. No need to adjust: quick and economical start-up. 4. No mechanical moving parts: maintenance- free, ...
Process temperature: -30 °C - 60 °C
Process pressure: -0.5 bar - 10 bar
... the switching time - are grouped in freely selectable parameter combinations. The patented series of devices is maintenance- free, wear- free and is not sensitive to vibrations. BENEFITS • UNIVERSAL ...
MBA Instruments GmbH
Process temperature: -52 °C - 240 °C
... The float switch is typically used to switch alarms, pumps, signal lamps, valves, and horns via a contact protection relay. When connected to intrinsically safe electrical circuits, the intrinsically ...
Process temperature: -40 °C - 135 °C
Process pressure: -1 bar - 100 bar
... fluctuating level, for example when filling the tank. Compensation for foam, bubbles and condensation as well as for sticky fluids can be set in the Flex Programmer software. The CONTACT-RLBFI level switch ...
Riels Instruments
Process temperature: -40 °C - 250 °C
... Admittance Level Switch can detect capacitance as well as impedance between probe and vessel. It is flexible for various applications while consistently demonstrating immunity to buildup, especially for dust, coal ash ...
China Shenzhen Jiwei Automations Ltd.
Process temperature: 800 °C
Process pressure: 3 MPa
... frequency admittance level meter is a level control technology developed from capacitive level measurement technology, which is anti-hanging, more reliable, more accurate, and more applicable. Feizhuo's ...
... consumption, ultra-compact capacitive limit switches that are perfect for basic liquid level monitoring Application Area The VEGAPOINT Series of ultra-compact capacitive limit switches ...
Process temperature: 40 °C - 150 °C
Process pressure: 5 bar - 20 bar
... Micro Switches are located inside Housing. Principle of Side Mounted Level Switch Simple theory as liquid buoyancy is utilized for the main principle of this “FF” series. A change of ...
Process temperature: -40 °C - 260 °C
Process pressure: -0.1 MPa - 6 MPa
... DHE-FT Vibrating Level Switch is a control switch for level measurement developed and produced by DHE. This instrument combines the unique “ELL Signal Analysis Technology” and the ...
Process temperature: -20 °C - 150 °C
... its detection is not affected by the electrical parameters of the measured medium, regardless of liquid types Maintenance- free No maintenance is required after ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group