- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Open-channel flow meter
Open-channel flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... Permanent A/C powered flow meter (controller only) Highly accurate flow measurement using ultrasonic sensor technology Simple menu-driven system. Provides reliable and cost effective flow ...
Hach
Volumetric flow rate: 500 m³/h
... immersible electromagnetic flowmeter that applies Faraday's law of electromagnetic induction to measure flow. It is ideal for use with liquids and slurries having a conductivity above a certain value. There is absolutely ...
Process temperature: -20 °C - 80 °C
Process pressure: 0 psi - 10 psi
Precision: 0.25 %
... AVFM 6.1 Area-Velocity Flow Meter is 150 mm (5.9 in). Configuration is simple for the AVFM 6.1 Area Velocity Flow Meter. Just enter the pipe diameter or channel dimensions ...
Pulsar Measurement
... mimic an analog instrument. In this configuration the flow output is available as an analog signal and flow controllers will respond to analog commands. AUTO-ZERO. The Digital 300 Sériés of flow controllers ...
Process temperature: -20 °C - 70 °C
... Hybrid Flow Measurement with Surface Radar and Ultrasonic Profile Scanner Flow measurement for open channels as well as part filled pipes. Optimum results through ...
NIVUS GmbH
Process temperature: -20 °C - 70 °C
... ambient conditions. The large graphic display permits quick and easy commissioning of the flow meter system. Due to the modular construction of our radar flow meter system we can provide ...
NIVUS GmbH
Process temperature: -20 °C - 70 °C
... Allows high accurate flow measurements using the transit time method according to IEC 60041 for part filled and full pipes, open channels and water bodies. Up to 8 measurement paths. -Proven robust ...
NIVUS GmbH
Precision: 3, 5 %
... Parshall flumes, rectangular, and trapezoidal channels), the meter automatically calculates and outputs instantaneous flow rate and cumulative flow. This provides a maintenance-free, ...
Process temperature: -30 °C - 70 °C
... represents excellence in non-contact flow measurement for rivers, irrigation canals, and open waterways. Thanks to advanced radar technology, the instrument simultaneously detects level and velocity, calculating flow ...
ASIT ITALIA
Process temperature: 0 °C - 60 °C
... The AI.FFdoppler.CA-W system is the ultimate professional solution for flow measurement in open channels, rivers, and partially filled pipes. Thanks to advanced ultrasonic technology ...
ASIT ITALIA
Volumetric flow rate: 0.3 m³/h - 7,200 m³/h
Process temperature: -20 °C - 90 °C
Precision: 0.3 %
... Series system is the de facto standard solution for flow measurement in rectangular open channels. Designed to offer impeccable accuracy and superior structural strength, these channels ...
ASIT ITALIA
Process temperature: -40 °C - 120 °C
Precision: 2 %
... area‑velocity flow meter designed for open- channel flow measurement. It combines an advanced Digital Signal Processing (DSP) computer with up to eight ultrasonic speed ...
Process temperature: -20 °C - 50 °C
Process pressure: 4 bar
Precision: 0.25 %
... instrument for measuring flow in open channels. The system combines electronics, one or two ultrasonic or radar transducers mounted above the liquid, and a velocity meter. Flow ...
Process temperature: -30 °C - 80 °C
Precision: 2, 1 %
... solution for monitoring the flow or velocity of open channels, agricultural irrigation or groundwater. the best solution. Application : ● Open channel flow ...
Volumetric flow rate: 0.1 m³/h - 381,703.5 m³/h
Process temperature: -20 °C - 60 °C
Process pressure: 6 bar - 250 bar
... Electromagnetic flow meters do not have any moving parts and are often chosen because they are less obstructed, cost-effective, bi-directional, and provide highly accurate volume flow measurements. They ...
Volumetric flow rate: 0.1 l/s - 27,777.75 l/s
Process temperature: -20 °C - 80 °C
Precision: 0.25, 0.5 %
... measuring flow through an open channel flow meter is to measure the height or HEAD of the liquid as it passes over an obstruction (a flume or weir) in the channel. ...
Process temperature: -40 °C - 85 °C
Precision: 1 %
Repeatibility: 0.1 %
... The RQ-30 is a sensor for continuous discharge measurement of rivers, open channels and canals with known cross-section profile. The sensor uses innovative radar technology to measure velocity, water ...
SOMMER Messtechnik GmbH
Process temperature: -40 °C - 85 °C
Precision: 1 %
... TRANSMISSION IN COMPACT Housing The RQ-30 ADMS is an all-in-one discharge measurement System. It contains the non-contact flow velocity and water level sensors of the RQ- 30 and applies the same algorithms and model to calculate the ...
SOMMER Messtechnik GmbH
Process temperature: -40 °C - 85 °C
Precision: 1 %
Repeatibility: 0.1 %
... proven RQ-radar technique: non-contact measurement, maintenance free system, flood-proof - No structural work is necessary in the water - Recognition of flow direction and hysteresis effects - Measurement ...
SOMMER Messtechnik GmbH
... Ultraflux UF 831 CO/RV enable to measure the flow of free-surface, open channels, sewers, rivers and partially filled pipes. To measure this flow a combination of velocity and level measurements ...
Process temperature: 50 °C
... High performance fixed installation Area Velocity flowmeter with extended features for open channel, part-filled pipe and river application. Dimensions: 166x161 x103 mm; Wall mounting ABS enclosure; Protection ...
Volumetric flow rate: 0.9 m³/h - 6,627 m³/h
... transmitter can be used for all flume types - Displaying of flow measurement and average or total flow - Certification of measurement Applications - For open channels, ...
Process temperature: 0 °C - 49 °C
... provides the most accurate measurement. Teledyne Isco 730 Bubbler Flow Modules use an internal air compressor to force a metered amount of air through a bubble line submerged in the flow channel. By ...
Teledyne Isco
... hydroengineering applications, was developed for ultrasonic flow measurements in filled and partially filled pipes and open channels. Whether for penstock monitoring, turbine and pump efficiency measurements ...
... Radar Open Channel Flowmeter Combined Sensor for velocity, level, temperature,instantaneously flow, accumulated flow Powersupply: 9~28VDC Output: RS485 Modbus RTU/4-20mA ...
Shaanxi Sier Electronics Co., Ltd.
Process temperature: -30 °C - 70 °C
Precision: 0.3, 0.1 %
COMETEC SA
Process temperature: -20 °C - 70 °C
... This flowmeter measures accurate flow rate with a precise sensor and provides various weir and plume measurement formulas, making it easy to use according to the user's environment. Main features Open ...
Volumetric flow rate: 0 l/s - 999,999 l/s
Process temperature: -40 °C - 70 °C
... Application: ultrasonicopen channel flow meter is non-contact type device, it use reflection of soundwaves theory to detect level and get flow by calculation. The meter ...
... The MQU is the Arkon ultrasonic flowmeter for open chanels. It should be use in combination of a flume. It consist in Arkon’s MQU tranmitter and a probe. The probe has a measurement range of 0.5, 2 or 4 meters. ...
Volumetric flow rate: 0 m³/h - 9,999 m³/h
Process temperature: 0 °C - 100 °C
... flow rate measurement on Channels with restrinctions on weirs ...
CHEMITEC
Process temperature: -40 °C - 140 °C
... demands. deltawave is an ultrasonic flow metering system for water and wastewater in a wide range of applications, for example in filled pipes, partially filled pipes, open channels and rivers. The ...
Process temperature: -40 °C - 70 °C
... PLCM open channel flow meter is an economical solution for open channel measuring, which measures level, flow rate and total volume ...
... ultrasonic level meter that comes with five relays, suitable for OCF ( Open Channel Flow) applications. The device supports no less than 17 flumes and weirs, being able ...
Solidat Applied Technologies Ltd.
Volumetric flow rate: 2 l/min
Process temperature: -40 °C - 85 °C
... temperature and flow compensation 3. High sensitivity, fast response, accurate and stable data 4. Small size and low energy consumption 3.Applications: ● Gas flow detection ● Flow monitoring of ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group