- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Volume flow meter
Volume flow meters
Volumetric flow rate: 0.1 m³/h - 68 m³/h
Process temperature: 0 °C - 85 °C
Process pressure: 0 bar - 250 bar
... as the primary sensor; its rotational speed is proportional to the flow rate. The rotational speed is detected by means of a biased Hall sensors, i.e. there are no magnets in the flow space. The FLEX transducer located ...
VAL.CO srl
Volumetric flow rate: 0.2 l/h - 220 l/h
Process temperature: 0 °C - 65 °C
Process pressure: 0 bar - 6 bar
... moves in a transparent conical measurement tube, relative to the flow. The position of the float depends on the volume flow (weight force versus resistance to flow), and indicates the ...
VAL.CO srl
Volumetric flow rate: 1 l/min - 75 l/min
Process temperature: 0 °C - 65 °C
Process pressure: 0 bar - 6 bar
... moves in a transparent conical measurement tube, relative to the flow. The position of the float depends on the volume flow (weight force versus resistance to flow), and indicates the ...
VAL.CO srl
Process temperature: -20 °C - 80 °C
... AFM-3 Flow Meter Specifications Usage:For testing liquid flow rate, Commonly used in smart toilets, drinkingfountains, etc. Parameters - AFM-3 Rated voltage - 5 VDC Rated flow ...
ALLDOO Micropump | Micro Diaphragm Pumps
Process temperature: 20 °C
... LED blinks when flow is measured and hence optically displays correct operation of the cooling system. These LEDs not only serve the functional purpose but additionally look great! Product Information The FlowMeter ...
ALLDOO Micropump | Micro Diaphragm Pumps
Process temperature: 120 °C
... 1/2 inch DN15 Transparent Water Flow Meter Flow MeterHall Flow Sensor Indicator Counter Specification: Appearance: clear product identification,accurate ...
ALLDOO Micropump | Micro Diaphragm Pumps
... modern and precise flow meter with internal data logging. Equipped with two analogue inputs and two PULS inputs, can measure flow and other values, such as temperature and humidity. In addition FP4 has ...
Volumetric flow rate: 0.1 l/min - 30 l/min
Process temperature: -20 °C - 90 °C
Process pressure: 16 bar
... for this magnetic flow meter are diverse: Can be used in areas where flow sensors with moving parts (paddle wheel, turbine sensors) cannot be applied due to contaminated media Sensor is intended for ...
Mass Flow ONLINE BV
Volumetric flow rate: 0.04 us gal/min - 160 us gal/min
Process temperature: 34 °F - 140 °F
Process pressure: 0.12 psi - 175 psi
... ® Ultrasonic inline meters for residential applications have no moving parts, which leads to improved reliability, increased performance and maximized revenue. Ease of Use. Display reports consumption, rate of flow, ...
Badger Meter
Volumetric flow rate: 7 l/min - 120 l/min
Process temperature: 16 °C
Process pressure: 20, 100 bar
... is a digital flow meter with turbine suitable for diesel monitoring and digital management of the fluid dispensed. PRECISION AND QUALITY The K24-A digital diesel flow meter has been ...
PIUSI
Volumetric flow rate: 80 l/h - 11,000 l/h
Process temperature: -18 °C - 50 °C
Process pressure: 15,000, 10,000 psi
... Use of an ultrasonic flowmeter is replacing intrusive flow measurement techniques in other designs, introducing a step change in CIMV technology. The ultrasonic flowmeter fires an ultrasonic pulse with ...
CAMERON
Process temperature: 0 °C - 870 °C
Process pressure: 0 bar - 1,378.95 bar
... The V-Cone Flow Meter is an advanced differential pressure instrument, which is ideal for use with liquid, steam or gas media in rugged conditions where accuracy, low maintenance and cost are important. With its DP built-in ...
McCrometer
Process pressure: 0.6 mbar - 4 mbar
Precision: 0.2 %
... Robust housing Excellent flow mesurement accuracy, can measure duplex flow, electromagnetic debimeter with 4-20mA and other outputs General Features Excellent small flow mesurement accuracy, ...
Volumetric flow rate: 0.5 l/min - 150 l/min
Process temperature: -40 °C - 125 °C
Process pressure: 0 bar - 18 bar
... The vortex flow sensor type 200 is based on the Kármán vortex street. You can choose between various versions as integrated temperature measurement. This flow sensor without moving parts is insensitive to pollution and ...
HUBA CONTROL
Process temperature: -40 °C - 150 °C
Precision: 1 %
... free and there is no need for recurring calibrations. For liquids Stationary · portable Flow velocities: 0 ... ±30 m/s Measuring units: volume flow, flow velocity, thermal output Connection: ...
KOBOLD Messring GmbH
Volumetric flow rate: 0 l/min - 700 l/min
Process temperature: -10 °C - 125 °C
Process pressure: 25 bar - 40 bar
... Meters of the Flowal® series are based on a robust concept with simplicity and can be adapted to a wide field of applications. The innovative design is the result of merging long years experience with the latest technologies. The OR ...
Bopp & Reuther Messtechnik GmbH
Process temperature: 80 °C
... The most advanced portable ultrasonic flow meter is available. Incorporationg over 30 years of field experience, the UF 801-P is the ideal ultrasonic portable flow meter for your diagnosis ...
ULTRAFLUX
Volumetric flow rate: 0 m³/h - 94,800 m³/h
Process pressure: 0 Pa - 1,000 Pa
... The electronic PREMASREG® 716x pressure sensor and switch is equipped with measuring functions for volume flow, differential pressure, filter monitoring and liquid level detection based on pressure measurement in clean ...
S+S Regeltechnik
Process temperature: -40 °F - 1,200 °F
... orifice fittings. Protection from high pressure & toxic flow media Accurate flow measurement Highest quality manufacturing Available as fitting only, retrofit or complete AGA-3 or ISO-5167 meter. Design Orifice ...
Canalta Controls Ltd.
Volumetric flow rate: 21 l/min - 200 l/min
Process temperature: 0 °C - 100 °C
... triggered by this micro-switch. Furthermore, a display system is activated that shows the current flow quantity on the scale. Display of the current flow simple adjustment of the switching points in accordance ...
Process temperature: -20 °C - 60 °C
Process pressure: 10,000 Pa
... APPLICATION One instrument for measurement of pressure, air flow, temperature and relative humidity Is tested to comply with standards for ’Ventilation for buildings – test procedures & measuring methods for handing over installed ventilation ...
Volumetric flow rate: 30 l/h - 1,200 l/h
Process temperature: -20 °C - 90 °C
Process pressure: 16 bar - 750 bar
... The PSF80x low-cost flow sensor, offered by COMECO, is manufactured by SWISSFLOW. The patented Swissflow technology is the basis for the highgrade liquid flow meters. The rotor housing with its special ...
Comeco Control & Measurement
Volumetric flow rate: 5.3 l/min - 524 l/min
Process temperature: -25 °C - 100 °C
Process pressure: 0 bar - 10 bar
... optional). Probe material: stainless steel. Working temperature range up to +100 °C. Suitable for fixed measuring of flow rate V/t [m³/h, l/min] in clean gases, briefly also in particle-laden mediums. Signal evaluation with ...
Höntzsch GmbH & Co KG
Process pressure: 70,000 Pa - 130,000 Pa
The model 6700 is a handheld micromanometer with Bluetooth® wireless capability; it takes airflow and pressure readings with a pitot tube or the optional velocity grid. The grid is a cross shaped grid, similar to the one in the base of the capture hood, ...
Process temperature: 0 °C - 250 °C
Precision: 2 %
... The DOPPLER flowmeters are designed to measure the volumetric flow in closed and full pipes. It consists of two sensors an emitter and an ultrasonic receiver. The emitted waves are transmitted by the transmitting gel ...
Sensotec Instruments
Volumetric flow rate: 0.2 l/min - 250 l/min
Process temperature: 0 °C - 100 °C
Process pressure: 0 bar - 10 bar
... Flow monitor and indicator for liquids wide measuring range sturdy construction high switch accuracy installation in any orientation Operation: The flow monitors ...
Meister Strömungstechnik GmbH
Volumetric flow rate: 0.1 l/min - 40 l/min
Process temperature: 0 °C - 100 °C
Process pressure: 0 bar - 20 bar
... attained by the float in its tapered flow tube is directly related to a calibrated scale with the flow being read from the centre of the ball. from the centre of the ball. This range of flowmeters ...
Filton Process Control Engineering
... cone, whereas for the Venturi nozzle, the inlet contour matches that of the ISA 1932 flow nozzle. The major advantage of the Venturi over orifice plates and flow nozzles is in the area of pressure recovery. Typically, ...
Volumetric flow rate: 0.9 m³/h - 6,627 m³/h
... ultrasonic level transmitter - Level transmitter can be used for all flume types - Displaying of flow measurement and average or total flow - Certification of measurement Applications - For open channels, ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group