With integrated temperature measurement
Compact and sturdy stainless steel design
Integrated overvoltage protection
Special calibration for all standard pressure units possible
Application
For electronic, continuous level measurement, e.g. in wells, drilling holes, water, containers or in waste water systems. Suitable for groundwater, waste water (with optional FEP cable), diesel fuel and fuel oil.
Description
Pressure transducers HydroFox® DMU 08 convert physical pressure into an electrical signal proportional to the pressure. HydroFox® DMU 08 uses a piezo-resistive silicon measuring cell.
Technical data
Measuring accuracy
Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
Measuring range
See ordering table
Dynamic characteristics
Response time:
≤ 10 ms
Probe
L x ⌀:
129 x 26.5 mm
Material
Housing:
Stainless steel 316 L
Diaphragm:
Stainless steel 316 L
Seals:
FKM (Viton)
Cable:
PUR
Pressure transmission liquid
Silicone oil
Supply voltage
Pressure:
DC 12 – 30 V
Temperature:
DC 10 – 30 V
Output signal
4–20 mA, 2-wire
Load
RMax = [(UB – UBMin)/0.02 A] Ω
Current input
< 25 mA
Electrical protection
Short circuit proof and protected against reverse polarity
Electrical connection
PUR cable with integrated breather tube for reference to the ambient atmospheric pressure
Cable length:
5 m
Degree of protection:
IP 68 (EN 60529)
CE conformity
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
Pressure Equipment Directive 2014/68/EU