Chemical-resistant plastic version
Robust ceramic diaphragm without transmission liquid
Highly resistant FEP cable
Special calibration for all standard pressure units possible
Application
For electronic, continuous level measurement in extremely corrosive liquids, e.g. chemicals or waste water from landfill sites.
Description
Pressure transducers HydroFox® convert physical pressure into an electrical signal proportional to the pressure. HydroFox® DMU 09 uses a capacitance ceramic measuring cell.
Technical data
Measuring accuracy
Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
Measuring range
See ordering table
Dynamic characteristics
Response time:
< 200 ms
Probe
L x ⌀:
126 x 45 mm
Material
Housing:
PP
Diaphragm:
Ultra-pure ceramic (Al203 99.9 %)
Seals:
FKM (Viton)
Cable:
FEP
Supply voltage
DC 9 – 32 V
Output signal
4–20 mA, 2-wire
Load
RMax = [(UB – UBMin)/0.02 A] Ω
Current input
< 21 mA
Electrical protection
Short circuit proof and protected against reverse polarity
Electrical connection
FEP cable with integrated breather tube for reference to the ambient atmospheric pressure
Cable length:
5 m
Degree of protection:
IP 68 (EN 60529)
CE conformity
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
Pressure Equipment Directive 2014/68/EU
Options
Housing PVDF
Cable protection conduits
Seals made of FFKM
Ex version
Ex II 1/2G Ex ia IIC T4 Ga/Gb
Ex II 1G Ex ia IIC or IIB T6 or T4 Ga (metal housing)
Ex II 1/2D Ex ia IIIC T 110 °C Da/Db
Ex II 10 Ex ia IIIC T 110 °C (metal housing)