Characteristics

Mounting / format
benchtop
Type
AC/AC
Network
single-phase, three-phase
Certifications
CE
Connection
with USB outlet
Secondary function
measuring device
Other characteristics
programmable, digital
Input voltage

400 V

Output voltage

Max.: 312 V

Min.: 0 V

Current

Max.: 50 A

Min.: 0 A

Power

Max.: 18,000 W

Min.: 3,000 W

Description

Overview
The Ls-Lx Series is a family of programmable AC power sources and analyzers covering 3 kVA to 18 kVA. Ls models provide an economical, improved successor to the classic L Series with optional arbitrary waveform and harmonic measurement features. Lx models combine flexible AC source functions with an integrated high-performance power analyzer for extended measurement and waveform capabilities.

Model summary
Model: Ls-Lx Series
Voltage range: 0–312 V (line-to-neutral standard)
Current: up to 50 A (model dependent)
Power: 3 kVA–18 kVA (single chassis up to 6 kVA; multi-chassis up to 18 kVA)

Ls Series
  • Improved economical version of the California Instruments L Series.
  • Available in single-phase (-1) or three-phase (-3) configurations.
  • Single-chassis power up to 6 kVA; systems can be paralleled to achieve up to 18 kVA.
  • Microprocessor control with front-panel keypad and backlit alphanumeric LCD.
  • Analog controls for dynamic slewing of voltage and frequency.
  • Optional: arbitrary waveform generation, harmonic measurements, DO-160 or MIL-STD-704 firmware.
  • Standard remote interfaces: USB and RS232C; optional GPIB and LAN.

Lx Series
  • Microprocessor controlled with simplified front-panel operation and analog slew controls.
  • Precise output regulation and high load drive capability.
  • Integrated power analyzer for voltage and current harmonic analysis and waveform capture.
  • Supports arbitrary waveform generation and extended harmonic measurements with options.
  • Standard remote interfaces: IEEE-488 (GPIB) and RS232C; SCPI command support for remote programming.
  • Optional avionics/defense test firmware (DO-160, MIL-STD-704) available.

Features and benefits
Key features - Ls Series
  • Backward compatibility with L Series functions and bus protocols.
  • Single- and three-phase operation suitable for industrial and avionics test applications.
  • Scalable power via multi-chassis configurations.
  • Transient programming for AC line disturbance simulation.
  • Built-in measurements: voltage, current, power and basic waveform parameters.
  • Optional advanced functions: arbitrary waveform generator, harmonic analysis, GPIB interface.
  • Interfaces: USB & RS232C standard; GPIB & LAN optional.

Key features - Lx Series
  • Compatibility with legacy HP6834B and iL Series functions where applicable.
  • Single- and three-phase modes for test bench and system integration.
  • Multi-chassis systems deliver higher total power (up to ~17.3 kVA depending on configuration).
  • Arbitrary waveform generator for harmonics and distortion testing.
  • Built-in power analyzer for detailed harmonic and time-domain measurements.
  • Standard interfaces: IEEE-488, USB & RS232 for remote control and ATE integration.

Features details - Ls Series
  • Backward compatibility: function and bus compatibility with CI L Series; APE command syntax available via -GPIB option.
  • Applications: precision regulation, high load drive current, avionics/defense testing with optional firmware.
  • Transient programming: programmable lists of voltage/frequency/phase/waveform steps; front panel or GUI execution and PC download.
  • Standard measurements: frequency, phase, Vrms, Irms, peak current, crest factor, real/apparent power, power factor.

Features details - Lx Series
  • Measurement system: real-time digitization with a 4K-sample buffer and DSP for RMS, power and FFT harmonic extraction (up to 50 harmonics, fundamentals to 250 Hz).
  • Waveform generation: sine, clipped sine and user-defined arbitrary waveforms; harmonic definition up to 50 harmonics with GUI storage.
  • Advanced measurements: voltage/current amplitude and phase harmonics, THD, and time-domain waveform capture; data can be displayed, logged and exported via GUI or bus.
  • Diagnostics: self-test with error reporting.

Windows Graphical User Interface (GUI)
  • Soft front panel for PC control.
  • GUI functions: full output parameter control; create/run/save/print transient programs; measure and log standard and advanced measurements.
  • With -ADV option: generate/save arbitrary and harmonic waveforms; capture and display voltage/current waveforms and harmonic data.

Notes
End-of-life (EOL) announced February 28, 2023; Last Time Buy until September 30, 2023. Recommended replacement family: Asterion AC Single & Three Phase power sources (replacement depends on model/configuration).

Output options
  • -AX: Auxiliary outputs (26 VAC, 5 VAC); limits upper frequency to 800 Hz.
  • -HV: 156/312 V output range.
  • -EHV: 200/400 V output range.
  • -HF: extends upper frequency limit (check compatibility table).
  • -LF: limits output frequency to 500 Hz.
  • -FC: modifies output frequency control to ±0.25%.

Controller options
  • -ADV: advanced feature set (arbitrary waveform generation, harmonic analysis).
  • -EXS: external synchronization.
  • -GPIB: IEEE-488 interface and APE programming language.
  • -LAN: Ethernet interface.
  • -MB: multi-box controller for auxiliary chassis.
  • -MODE: adds phase mode selections for -3 models.
  • -L22 / -LKM / -LKS / -LNS: locking knobs, clock/lock master/auxiliary, line sync options.

Avionics test routine options
  • -ABD / -AMD / -A350 / -AIRB: Airbus test suites and combinations (requires -ADV and PC software).
  • -704 / -704F: MIL-STD-704 firmware variants.
  • -160: RTCA/DO-160D section 16 and related firmware.

Cabinet options
C prefix: installed and pre-wired 19" cabinet systems.

Compatibility notes
Option compatibility depends on specific model configuration; consult factory documentation for HF, LF, HV, EHV and multi-chassis compatibility.

Supplied with
User/programming manual on CD-ROM, software and RS232C serial cable.

Technical specifications
  • Series name: Ls-Lx Series.
  • Variants: Ls Series and Lx Series, single-phase and three-phase models.
  • Voltage range: 0–312 V LN standard; optional ranges and line-to-line maxima on 3-phase models with -HV/-EHV options.
  • Current: 0–50 A depending on model.
  • Power: 3–18 kVA (single chassis to 6 kVA; multi-chassis to 17–18 kVA depending on model).
  • Waveform modes: sine, clipped sine, square, harmonic and user-defined arbitrary waveforms (with -ADV option).
  • Measurements: frequency, phase, Vrms, Irms, peak current, crest factor, real/apparent power, power factor; Lx adds extended harmonic analysis.
  • Harmonic analysis: up to 50 harmonics (with advanced options) for fundamentals up to 250 Hz.
  • Transient generation: programmable step lists and GUI libraries.
  • Interfaces: USB & RS232C standard; IEEE-488 (GPIB) and LAN optional/standard depending on model.
  • Remote control: SCPI support (Lx) and APE command syntax for legacy compatibility (Ls with -GPIB).
  • Diagnostics: self-test with error reporting.
  • Software: Windows GUI for control, waveform generation, transient programming and data logging.
  • Optional avionics/defense firmware and test suites: DO-160, MIL-STD-704, Airbus/Boeing specific packages.

Catalogs

No catalogs are available for this product.

See all of AMETEK Programmable Power‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.